Nonlinear observer to estimate polarization phenomenon in membrane distillation

This paper presents a bi-dimensional dynamic model of Direct Contact Membrane Desalination (DCMD) process. Most of the MD configuration processes have been modeled as steady-state one-dimensional systems. Stationary two-dimensional MD models have been considered only in very few studies. In this work, a dynamic model of a DCMD process is developed. The model is implemented using Matlab/Simulink environment. Numerical simulations are conducted for different operational parameters at the module inlets such as the feed and permeate temperature or feed and permeate flow rate. The results are compared with experimental data published in the literature. The work presents also a feed forward control that compensates the possible decrease of the temperature gradient by increasing the flow rate. This work also deals with a development of nonlinear observer to estimate temperature polarization inside the membrane. The observer gives a good profile and longitudinal temperature estimations and shows a good prediction of pure water flux production.

[1]  Noreddine Ghaffour,et al.  Performance investigation of a solar-assisted direct contact membrane distillation system , 2013 .

[2]  H. Trinh,et al.  Design of unknown input functional observers for nonlinear systems with application to fault diagnosis , 2013 .

[3]  Kim Dam-Johansen,et al.  Characterization of microporous membranes for use in membrane contactors , 1997 .

[4]  Paul M. Frank,et al.  Robust Component Fault Detection and Isolation in Nonlinear Dynamic Systems using Nonlinear unknown Input Observers , 1991 .

[5]  Lidia Roca,et al.  Dynamic modeling and performance of the first cell of a multi-effect distillation plant , 2014 .

[6]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[7]  Ho-Ming Yeh,et al.  Theoretical modeling and experimental analysis of direct contact membrane distillation , 2009 .

[8]  Anthony G. Fane,et al.  Gas and vapour transport through microporous membranes. I. Knudsen-Poiseuille transition , 1990 .

[9]  Noam Lior,et al.  Membrane-distillation desalination: Status and potential , 2005 .

[10]  R. W. Rousseau,et al.  Elementary principles of chemical processes , 1978 .

[11]  Vincent Cocquempot,et al.  Nonlinear unknown input observer design for diesel engines , 2013, 2013 American Control Conference.

[12]  M. Saif A Disturbance Accommodating Estimator for Bilinear Systems , 1993, 1993 American Control Conference.

[13]  Anthony G. Fane,et al.  Heat and mass transfer in membrane distillation , 1987 .

[14]  Mohamed Khayet,et al.  Coupling of a membrane distillation module to a multieffect distiller for pure water production , 1998 .

[15]  Wolfgang Marquardt,et al.  Dynamic modeling of direct contact membrane distillation processes , 2012 .

[16]  Matthias Rommel,et al.  Solar thermal driven desalination plants based on membrane distillation , 2003 .

[17]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[18]  D. R. Lloyd,et al.  Membrane distillation. II. Direct contact MD , 1996 .

[19]  E. Drioli,et al.  MEMBRANE DISTILLATION , 2012 .

[20]  P. S. Teh,et al.  Observer-based residual design for nonlinear systems with unknown inputs , 2011, 2011 Australian Control Conference.

[21]  Paul M. Frank,et al.  Nonlinear observer design via an extended observer canonical form , 1990 .