Optimized preparation of pDNA/poly(ethylene imine) polyplexes using a microfluidic system.

Poly(ethylene imine) (PEI) is an established non-viral vector system for the delivery of various nucleic acids in gene therapy applications. Polyelectrolyte complexes between both compounds, so called polyplexes, are formed by electrostatic interactions of oppositely charged macromolecules and are thought to facilitate uptake into cells. Such complexes form spontaneously and on lab scale they are usually prepared by mixing solutions through pipetting. Hence, an optimized preparation procedure allowing the scale-up of well-defined polyplexes would be of general interest. We developed a new method for microfluidic polyplex preparation on a chip. The mixing behaviour within the microfluidic channels was evaluated. Polyplexes with PEI and plasmid DNA were prepared using this method, in comparison to the standard pipetting procedure. Sizes and polydispersity indices of these complexes were examined. The influence of various parameters on the polyplex characteristics and the suitability of this production procedure for other PEI-based complexes were also evaluated. It was shown that polyplexes could easily be prepared by microfluidics. The ratio of PEI to DNA was most important for the formation of small polyplexes, whereas other parameters had minor influence. The size of polyplexes prepared with this new method was observed to be relatively constant between 140 nm and 160 nm over a wide range of complex concentrations. In comparison, the size of polyplexes prepared by pipetting (approximately 90 nm to 160 nm) varied considerably. The versatility of this system was demonstrated with different (targeted) PEI-based vectors for the formation of complexes with pDNA and siRNA. In conclusion, polyplex preparation using microfluidics could be a promising alternative to the standard pipetting method due to its suitability for preparation of well-defined complexes with different compositions over a wide range of concentrations.

[1]  Zhengzheng Fei,et al.  Delivery of polyethylenimine/DNA complexes assembled in a microfluidics device. , 2009, Molecular pharmaceutics.

[2]  Guido Marcucci,et al.  Delivery of antisense oligodeoxyribonucleotide lipopolyplex nanoparticles assembled by microfluidic hydrodynamic focusing. , 2010, Journal of controlled release : official journal of the Controlled Release Society.

[3]  L. Fu,et al.  Microfluidic Mixing: A Review , 2011, International journal of molecular sciences.

[4]  A. Aigner,et al.  A low molecular weight fraction of polyethylenimine (PEI) displays increased transfection efficiency of DNA and siRNA in fresh or lyophilized complexes. , 2006, Journal of controlled release : official journal of the Controlled Release Society.

[5]  Yundong Wang,et al.  A State-of-the-Art Review of Mixing in Microfluidic Mixers , 2008 .

[6]  Julianna Lisziewicz,et al.  Rational development of a stable liquid formulation for nanomedicine products. , 2010, International journal of pharmaceutics.

[7]  W. Hennink,et al.  The effect of formulation parameters on the size of poly-((2-dimethylamino)ethyl methacrylate)-plasmid complexes. , 1999, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[8]  T. Etrych,et al.  Polyelectrolyte complex formation and stability when mixing polyanions and polycations in salted media: a model study related to the case of body fluids. , 2005, European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences.

[9]  O. Zelphati,et al.  Stable and monodisperse lipoplex formulations for gene delivery , 1998, Gene Therapy.

[10]  Leslie Y Yeo,et al.  Microfluidic devices for bioapplications. , 2011, Small.

[11]  Y. Won,et al.  Polymer-based siRNA delivery: perspectives on the fundamental and phenomenological distinctions from polymer-based DNA delivery. , 2007, Journal of controlled release : official journal of the Controlled Release Society.

[12]  M. Vert,et al.  A Physico-chemical Approach of Polyanion-Polycation Interactions Aimed at Better Understanding the In Vivo Behaviour of Polyelectrolyte-based Drug Delivery and Gene Transfection , 2003, Journal of drug targeting.

[13]  T. Andresen,et al.  Revisit complexation between DNA and polyethylenimine--effect of length of free polycationic chains on gene transfection. , 2011, Journal of controlled release : official journal of the Controlled Release Society.

[14]  V. Hessel,et al.  Micromixers—a review on passive and active mixing principles , 2005 .

[15]  A. Kichler Gene transfer with modified polyethylenimines , 2004, The journal of gene medicine.

[16]  W. Seeger,et al.  Effects of cell‐penetrating peptides and pegylation on transfection efficiency of polyethylenimine in mouse lungs , 2008, The journal of gene medicine.

[17]  Y. Zhan,et al.  Vortex-assisted DNA delivery. , 2010, Lab on a chip.

[18]  D. Scherman,et al.  A versatile vector for gene and oligonucleotide transfer into cells in culture and in vivo: polyethylenimine. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[19]  D. Schaffert,et al.  The establishment of an up-scaled micro-mixer method allows the standardized and reproducible preparation of well-defined plasmid/LPEI polyplexes. , 2011, European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V.

[20]  Tza-Huei Wang,et al.  The convergence of quantum-dot-mediated fluorescence resonance energy transfer and microfluidics for monitoring DNA polyplex self-assembly in real time , 2009, Nanotechnology.

[21]  C. Ruppert,et al.  Biophysical investigation of pulmonary surfactant surface properties upon contact with polymeric nanoparticles in vitro. , 2011, Nanomedicine : nanotechnology, biology, and medicine.

[22]  Y. Li,et al.  Characterization of commercially available and synthesized polyethylenimines for gene delivery. , 2000, Journal of controlled release : official journal of the Controlled Release Society.

[23]  P. Tabeling,et al.  A brief introduction to slippage, droplets and mixing in microfluidic systems. , 2009, Lab on a chip.

[24]  Jing-Tang Yang,et al.  Characterization of microfluidic mixing and reaction in microchannels via analysis of cross-sectional patterns. , 2011, Biomicrofluidics.

[25]  R. Chandra,et al.  Cationic polymer based nanocarriers for delivery of therapeutic nucleic acids. , 2011, Journal of biomedical nanotechnology.

[26]  Roland Zengerle,et al.  Microfluidic platforms for lab-on-a-chip applications. , 2007, Lab on a chip.