Interface of data transmission for a transcutaneous communication system using the human body as transmission medium

We have been developing a new transcutaneous communication system (TCS) that uses the human body as an electrical conductive medium. We studied an interface circuit of the TCS in order to optimize the leading data current into the human body effectively. Two types of LC circuits were examined for the interface circuit, one was an LC series-parallel circuit, and the other was a parallel-connected LC circuit. The LC series-parallel circuit connected to the body could be tuned to a resonant frequency, and the frequency was determined by the values of an external inductor and an external capacitor. Permittivity of the body did not influence the electrical resonance. Connection of the LC series-parallel circuit to the body degraded the quality factor Q because of the conductivity of the body. However, the LC parallel-connected circuit when connected to the body did not indicate electrical resonance. The LC series-parallel circuit restricts a direct current and a low-frequency current to flow into the body; thus, it can prevent a patient from getting a shock. According to the above results, an LC series-parallel circuit is an optimum interface circuit between the TCS and the body for leading data current into the body effectively and safely.

[1]  Thomas G. Zimmerman,et al.  : Near-field , 2022 .

[2]  Eiji Okamoto,et al.  Basic study of a transcutaneous information transmission system using intra-body communication , 2010, Journal of Artificial Organs.

[3]  Wolfgang Fichtner,et al.  Galvanic Coupling Enabling Wireless Implant Communications , 2009, IEEE Transactions on Instrumentation and Measurement.

[4]  Yusuke Inoue,et al.  Development of a bidirectional transcutaneous optical data transmission system for artificial hearts allowing long-distance data communication with low electric power consumption , 2005, Journal of Artificial Organs.

[5]  Eiji Okamoto,et al.  Feasibility of a remote monitoring system for patients with an implantable left ventricular assist device using Personal Handy-Phone System telecommunication technology , 2006, Journal of Artificial Organs.

[6]  Eiji Okamoto,et al.  Computer assisted design for the implantable left ventricular assist device (LVAD) blood pump using computational fluid dynamics (CFD) and computer-aided design and manufacturing (CAD/CAM) , 2006, Journal of Artificial Organs.

[7]  H. Hosaka,et al.  Development and performance analysis of an intra-body communication device , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[8]  J.H. Hwang,et al.  Effect of load impedance on the signal loss of human body communication , 2007, 2007 IEEE Antennas and Propagation Society International Symposium.