Using trainable hearing aids to examine real-world preferred gain.

BACKGROUND While there have been many studies of real-world preferred hearing aid gain, few data are available from participants using hearing aids with today's special features activated. Moreover, only limited data have been collected regarding preferred gain for individuals using trainable hearing aids. PURPOSE To determine whether real-world preferred hearing aid gain with trainable modern hearing aids is in agreement with previous work in this area, and to determine whether the starting programmed gain setting influences preferred gain outcome. RESEARCH DESIGN An experimental crossover study. Participants were randomly assigned to one of two treatment groups. Following initial treatment, each subject crossed to the opposite group and experienced that treatment. STUDY SAMPLE Twenty-two adults with downward sloping sensorineural hearing loss served as participants (mean age 64.5; 16 males, 6 females). All were experienced users of bilateral amplification. INTERVENTION Using a crossover design, participants were fitted to two different prescriptive gain conditions: VC (volume control) start-up 6 dB above NAL-NL1 (National Acoustic Laboratories-Non-linear 1) target or VC start-up 6 dB below NAL-NL1 target. The hearing aids were used in a 10 to 14 day field trial for each condition, and using the VC, the participants could "train" the overall hearing aid gain to their preferred level. During the field trial, daily hearing aid use was logged, as well as the listening situations experienced by the listeners based on the hearing instrument's acoustic scene analysis. The participants completed a questionnaire at the start and end of each field trial in which they rated loudness perceptions and their satisfaction with aided loudness levels. RESULTS Because several participants potentially experienced floor or ceiling effects for the range of trainable gain, the majority of the statistical analysis was conducted using 12 of the 22 participants. For both VC-start conditions, the trained preferred gain differed significantly from the NAL-NL1 prescriptive targets. More importantly, the initial start-up gain significantly influenced the trained gain; the mean preferred gain for the +6 dB start condition was approximately 9 dB higher than the preferred gain for the -6 dB start condition, and this difference was statistically significant (p < .001). Partial eta squared (n2) = 0.919, which is a large effect size. Deviation from the NAL-NL1 target was not significantly influenced by the time spent in different listening environments, amount of hearing aid use during the trial period, or amount of hearing loss. Questionnaire data showed more appropriate ratings for loudness and higher satisfaction with loudness for the 6 dB below target VC-start condition. CONCLUSIONS When trainable hearing aids are used, the initial programmed gain of hearing instruments can influence preferred gain in the real world.

[1]  Robyn M. Cox,et al.  Using Loudness Data for Hearing Aid Selection: The IHAFF Approach , 1995 .

[2]  Hugh J. McDermott,et al.  The Design and Evaluation of a Hearing Aid with Trainable Amplification Parameters , 2007, Ear and hearing.

[3]  Todd A Ricketts,et al.  Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction. , 2005, Journal of the American Academy of Audiology.

[4]  H. Mueller Hearing Aid Verification : Old Concepts and New Considerations , 2007 .

[5]  Saeed Vaseghi,et al.  Advanced Signal Processing and Digital Noise Reduction , 1996 .

[6]  L E Humes,et al.  Prescribed clinician-fit versus as-worn coupler gain in a group of elderly hearing-aid wearers. , 2000, Journal of speech, language, and hearing research : JSLHR.

[7]  Harvey Dillon,et al.  What'S new from NAL in hearing aid prescriptions? , 2006 .

[8]  Jacob Cohen Multiple regression as a general data-analytic system. , 1968 .

[9]  H Gustav Mueller,et al.  Fitting hearing aids to adults using prescriptive methods: an evidence-based review of effectiveness. , 2005, Journal of the American Academy of Audiology.

[10]  Benjamin W Y Hornsby,et al.  The Effects of Digital Noise Reduction on the Acceptance of Background Noise , 2006, Trends in amplification.

[11]  Justin A. Zakis,et al.  Preferred overall loudness. II: Listening through hearing aids in field and laboratory tests , 2006, International journal of audiology.

[12]  Thomas A. Powers,et al.  New algorithm is designed to take the annoyance out of transient noise , 2007 .

[13]  B. Thompson,et al.  How to Estimate and Interpret Various Effect Sizes , 2004 .

[14]  Harvey Dillon What ’ s New in Prescriptive Fittings Down Under ? Gitte Keidser , .

[15]  Gitte Keidser,et al.  The trainable hearing aid: What will it do for clients and clinicians? , 2006 .

[16]  Sheila Moodie,et al.  The Desired Sensation Level Multistage Input/Output Algorithm , 2005, Trends in amplification.

[17]  Lorienne M Jenstad,et al.  Evaluation of the Desired Sensation Level [Input/Output] Algorithm for Adults with Hearing Loss: The Acceptable Range for Amplified Conversational Speech , 2007, Ear and hearing.

[18]  Benjamin W Y Hornsby,et al.  User preference and reliability of bilateral hearing aid gain adjustments. , 2008, Journal of the American Academy of Audiology.

[19]  P. Newall,et al.  Hearing aid gain and frequency response requirements for the severely/profoundly hearing impaired. , 1990, Ear and hearing.

[20]  Patrick N Plyler,et al.  The objective and subjective evaluation of multichannel expansion in wide dynamic range compression hearing instruments. , 2007, Journal of speech, language, and hearing research : JSLHR.

[21]  Gitte Keidser,et al.  Client-Based Adjustments of Hearing Aid Gain: The Effect of Different Control Configurations , 2008, Ear and hearing.

[22]  Gitte Keidser,et al.  Proprietary fitting algorithms compared with one another and with generic formulas , 2003 .

[23]  Catherine V Palmer,et al.  Amplification With Digital Noise Reduction and the Perception of Annoying and Aversive Sounds , 2006, Trends in amplification.

[24]  Gitte Keidser,et al.  A Review and Analysis: Does Amplification Experience Have an Effect on Preferred Gain over Time? , 2005 .

[25]  Karolina Smeds Is Normal or Less Than Normal Overall Loudness Preferred by First-Time Hearing Aid Users? , 2004, Ear and hearing.

[26]  G Keidser,et al.  NAL-NL1 procedure for fitting nonlinear hearing aids: characteristics and comparisons with other procedures. , 2001, Journal of the American Academy of Audiology.