OBJECTIVE
Assessment of the inter and intraobserver variability of the modified Rodnan (m-Rodnan) total skin thickness score by clinical palpation [a commonly used outcome measure in trials of systemic sclerosis (SSc)].
METHODS
Skin thickness was assessed by clinical palpation of 17 body areas on 0 to 3 scale (normal, mild, moderate, severe). The m-Rodnan total skin thickness score was derived by summation of the scores from all 17 body areas. Using the m-Rodnan, 6-7 investigators assessed skin thickness in 5-6 patients with SSc (22 patients and 23 examiners total) at each of 4 sessions for the determination of interobserver variability (accuracy). In addition 21 of the investigators then assessed m-Rodnan in 2-3 patients each (60 patients total) 3 times over a 2-8 week period to quantitate intraobserver variability (reliability).
RESULTS
Interobserver and intraobserver mean +/- within patient standard deviations (SD) for the m-Rodnan were found to be 17.7 +/- 4.6 and 20.7 +/- 2.45, respectively.
CONCLUSION
The m-Rodnan total skin thickness score is at least as reliable for measuring skin thickness in SSc as are the ARA and Ritchie joint tenderness counts for assessing joint disease in rheumatoid arthritis. These data are useful for the determination of sample size and for the definitions of clinically meaningful response. Assessment of skin score is sufficiently reproducible to include as a measure of disease outcome, especially if patients are serially evaluated by the same investigator.