Carbon-fibre plates for traumatic and (impending) pathological fracture fixation: Where do we stand? A systematic review
暂无分享,去创建一个
J. Schoones | M. A. van de Sande | S. Lozano-Calderón | O. Groot | Zeger Rijs | Amber Weekhout | Stef Daniel | M. V. D. van de Sande | Z. Rijs
[1] N. Depauw,et al. Evaluation of Carbon Fiber and Titanium Surgical Implants for Proton and Photon Therapy. , 2023, Practical radiation oncology.
[2] C. Gerhardt,et al. Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system , 2023, BMC Musculoskeletal Disorders.
[3] D. Campanacci,et al. Complications of patients with bone tumors treated with carbon-fiber plates: an international multicenter study , 2022, Scientific Reports.
[4] A. Bhashyam,et al. Carbon Fiber Implants in Orthopaedic Oncology , 2022, Journal of clinical medicine.
[5] A. Pellegrino,et al. Clinical and radiographic outcomes of distal radius fracture treatment with Carbon-Fiber-Reinforced-Polymer Volar Plates (CFR-PEEK): analysis of 40 cases , 2022, Lo Scalpello - Otodi Educational.
[6] H. Lill,et al. Minimum 2-year results of the second-generation CFR-PEEK locking plate on the proximal humeral fracture , 2022, European Journal of Orthopaedic Surgery & Traumatology.
[7] X. Griffin,et al. Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: A systematic review. , 2021, Journal of clinical orthopaedics and trauma.
[8] L. Herzog,et al. The Use of Carbon Fiber Implants for Impending or Existing Pathologic Fractures , 2021, Journal of orthopaedic trauma.
[9] M. Saracco,et al. SAFETY AND RELIABILITY OF CARBON-PEEK PLATE FOR THE TREATMENT OF DISTAL RADIUS FRACTURES: A REVIEW OF THE LITERATURE. , 2021, Orthopedic reviews.
[10] P. Giannoudis,et al. Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today , 2021, European Journal of Trauma and Emergency Surgery.
[11] J. Petersen,et al. Palmar plating of distal radius fractures : 3-year follow-up with titanium and PEEK plates give similar outcomes. , 2021, Acta orthopaedica Belgica.
[12] M. Rovers,et al. Innovators’ views on involving users and patients in surgical device development: a qualitative interview study , 2021, BMJ Open.
[13] Matthew B. Mellon. Late recognition of an early catastrophic failure of a carbon fiber reinforced distal femoral plate: A case report☆ , 2021, Trauma case reports.
[14] M. Bilsky,et al. Radiolucent carbon fiber-reinforced implants for treatment of spinal tumors- clinical, radiographic, and dosimetric considerations. , 2021, World neurosurgery.
[15] Carmine Zoccali,et al. A New Proximal Femur Reconstruction Technique after Bone Tumor Resection in a Very Small Patient: An Exemplificative Case , 2021, Children.
[16] P. Caravaggi,et al. Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants. , 2021, Journal of The Mechanical Behavior of Biomedical Materials.
[17] E. Mayo-Wilson,et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews , 2020, BMJ.
[18] T. Hickernell,et al. What Is the Learning Curve for New Technologies in Total Joint Arthroplasty? A Review , 2020, Current Reviews in Musculoskeletal Medicine.
[19] D. Doyle,et al. American Society of Anesthesiologists Classification , 2020 .
[20] D. Broekhuis,et al. Early Failure of a Carbon-Fiber-Reinforced Polyetheretherketone Distal Femur Plate: A Case Report. , 2020, JBJS case connector.
[21] F. Catani,et al. Volar PEEK plate for distal radius fracture: analysis of adverse events , 2020, European Journal of Orthopaedic Surgery & Traumatology.
[22] D. Hak,et al. Evaluation of callus formation in distal femur fractures after carbon fiber composite versus stainless steel plate fixation , 2020, European Journal of Orthopaedic Surgery & Traumatology.
[23] H. Rosenthal,et al. Ipsilateral rotational double‐barrel fibula autograft for limb salvage in a pediatric patient with lower extremity intramedullary osteosarcoma: A case report , 2020, Microsurgery.
[24] U. Stöckle,et al. The Treatment of Proximal Humerus Fracture Using Internal Fixation with Fixed-angle Plates. , 2019, Deutsches Arzteblatt international.
[25] H. Pape,et al. Clinical outcomes after carbon-plate osteosynthesis in patients with distal radius fractures , 2019, Patient safety in surgery.
[26] Natalie S Blencowe,et al. RoB 2: a revised tool for assessing risk of bias in randomised trials , 2019, BMJ.
[27] M. Farshad,et al. Carbon fibre/polyether ether ketone (CF/PEEK) implants in orthopaedic oncology , 2018, World Journal of Surgical Oncology.
[28] R. Balm,et al. Systematic review of shared decision‐making in surgery , 2018, The British journal of surgery.
[29] R. Lanzetti,et al. Preliminary experience with triangular CarboFix “Piccolo” Distal Radius Plate in wrist fractures. Clinical and radiological results , 2018, Acta bio-medica : Atenei Parmensis.
[30] F. Catani,et al. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures. , 2018, Orthopaedics & traumatology, surgery & research : OTSR.
[31] G. Merolla,et al. Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes , 2018, MUSCULOSKELETAL SURGERY.
[32] C. Collinge,et al. Early Comparative Outcomes of Carbon Fiber–Reinforced Polymer Plate in the Fixation of Distal Femur Fractures , 2018, Journal of orthopaedic trauma.
[33] Ashish B. Shah,et al. A Retrospective Case Series of Carbon Fiber Plate Fixation of Ankle Fractures , 2018, Foot & ankle specialist.
[34] M. Guzzini,et al. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures. , 2017, Injury.
[35] P. Maniscalco,et al. PEEK radiolucent plate for distal radius fractures: multicentre clinical results at 12 months follow up. , 2017, Injury.
[36] S. Boriani,et al. Composite PEEK/Carbon fiber implants can increase the effectiveness of radiotherapy in the management of spine tumors. , 2017, Journal of spine surgery.
[37] R. Lanzetti,et al. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. , 2017, Injury.
[38] H. Lill,et al. Outcomes of proximal humeral fracture fixation with locked CFR-PEEK plating , 2017, European Journal of Orthopaedic Surgery & Traumatology.
[39] M. Hernán,et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions , 2016, British Medical Journal.
[40] Randal P. Morris,et al. Torsional Failure of Carbon Fiber Composite Plates Versus Stainless Steel Plates for Comminuted Distal Fibula Fractures , 2016, Foot & ankle international.
[41] P. Behrendt,et al. Winkelstabile karbonverstärkte Polymerkompositplatte zur Versorgung einer distalen Radiusfraktur , 2015, Der Unfallchirurg.
[42] V. Chong. Orbital tumours , 2015, Cancer Imaging.
[43] U. Dirksen,et al. Ewing Sarcoma: Current Management and Future Approaches Through Collaboration. , 2015, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.
[44] C. Theisen,et al. Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate. , 2015, Journal of shoulder and elbow surgery.
[45] F. Catani,et al. Proximal humeral fracture fixation: multicenter study with carbon fiber peek plate , 2015, MUSCULOSKELETAL SURGERY.
[46] D. Perugia,et al. Preliminary experience with Piccolo Composite™, a radiolucent distal fibula plate, in ankle fractures. , 2014, Injury.
[47] D. Hak,et al. Use of carbon-fiber-reinforced composite implants in orthopedic surgery. , 2014, Orthopedics.
[48] R. Zdero,et al. Biomechanical analysis of a new carbon fiber/flax/epoxy bone fracture plate shows less stress shielding compared to a standard clinical metal plate. , 2014, Journal of biomechanical engineering.
[49] P. McGarry,et al. Investigation of metallic and carbon fibre PEEK fracture fixation devices for three-part proximal humeral fractures. , 2013, Medical engineering & physics.
[50] R. Zdero,et al. Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications. , 2013, Journal of the mechanical behavior of biomedical materials.
[51] G. Guyatt,et al. GRADE: an emerging consensus on rating quality of evidence and strength of recommendations , 2008, BMJ : British Medical Journal.
[52] Philippe Poitras,et al. Internal plate fixation of fractures: short history and recent developments , 2006, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.
[53] Peter Thomsen,et al. Aseptic loosening, not only a question of wear: A review of different theories , 2006, Acta orthopaedica.
[54] P. Alderman,et al. Carbon fibre plates in the treatment of femoral periprosthetic fractures. , 2004, Injury.
[55] A F Monk,et al. ASSESSMENT OF THE LEARNING CURVE IN HEALTH TECHNOLOGIES , 2000, International Journal of Technology Assessment in Health Care.
[56] Chaz Reetz-Laiolo. Animals , 1981, Restoration & Management Notes.