State of the Art in GIS PD Diagnostics

This paper presents the state of the art in GIS PD diagnostics. The guidelines for a risk assessment procedure on defects in GIS based on PD measurements are described. The procedure starts with sensitive PD measurements to detect critical defects and follows with an identification of the type of the defect and its location inside the GIS. This information, combined with other essential data from the manufacturer's experience and a trend analysis of the PD activity, is the base for the estimation of the criticality of the defects. Finally, the risk assessment is performed based on the estimated dielectric failure probability and failure consequences. To detect and eliminate critical insulation defects, PD monitoring systems are applied. The ultra-high frequency measurement method is used worldwide by GIS manufacturers during routine testing in the factory, during on-site commissioning and by utilities for continuous in-service monitoring.

[1]  B. F. Hampton,et al.  The excitation of UHF signals by partial discharges in GIS , 1996 .

[2]  F. Petzold,et al.  Guidelines for partial discharge detection using conventional (IEC 60270) and unconventional methods , 2016 .

[3]  S. Boggs Electromagnetic Techniques for Fault and Partial Discharge Location in Gas-Insulated Cables and Substations , 1982, IEEE Transactions on Power Apparatus and Systems.

[4]  L. Lundgaard Partial discharge. XIII. Acoustic partial discharge detection-fundamental considerations , 1992 .

[5]  F. Farmer REACTOR SAFETY AND SITING: A PROPOSED RISK CRITERION. , 1967 .

[6]  S. Tenbohlen,et al.  Risk assessment on defects in GIS based on PD diagnostics , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  S. Tenbohlen,et al.  UHF partial discharge detection system for GIS: Application guide for sensitivity verification: CIGRE WG D1.25 , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  Lars E. Lundgaard Particles in GIS characterization from acoustic signatures , 2001 .

[9]  Stefan M. Hoek,et al.  Tuned medium-band UHF PD measurement method for GIS , 2013 .

[10]  D CigreWg,et al.  High-Voltage On-Site Testing with Partial Discharge Measurement , 2012 .

[11]  Hitoshi Okubo,et al.  The relationship between partial discharge current pulse waveforms and physical mechanisms , 2002 .

[12]  U. Riechert,et al.  Experiences with UHF PD detection in GIS using external capacitive sensors on windows and disk-insulators , .

[13]  L.E. Lundgaard,et al.  Partial discharge. XIV. Acoustic partial discharge detection-practical application , 1992, IEEE Electrical Insulation Magazine.

[14]  Lars E. Lundgaard Particles in GIS Characterizatio n from Acoustic Signatures , 2001 .

[15]  M.A.S. Leijon,et al.  Pattern recognition of free metallic particle motion modes in GIS , 1988, Conference Record of the 1988 IEEE International Symposium on Electrical Insulation.

[16]  Martin D. Judd,et al.  Partial discharge diagnostics for gas insulated substations , 1995 .

[17]  Stefan Tenbohlen,et al.  A New Procedure for Partial Discharge Localization in Gas-Insulated Switchgears in Frequency Domain , 2005 .

[18]  A. Schnettler,et al.  Determination of a failure probability prognosis based on PD - diagnostics in gis , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  A. Bargigia,et al.  Detection of parallel discharges in gas insulated substations , 1992 .