Series and Parallel Arc-Fault Circuit Interrupter Tests

While the 2011 National Electrical Code%C2%AE (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by opening the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.

[1]  Jay Johnson,et al.  Accelerated life testing of PV arc-fault detectors , 2013, 2013 IEEE 39th Photovoltaic Specialists Conference (PVSC).

[2]  Sandia Report,et al.  Preliminary Photovoltaic Arc-Fault Prognostic Tests using Sacrificial Fiber Optic Cabling , 2013 .

[3]  Christian Strobl,et al.  Arc Faults in Photovoltaic Systems , 2010, 2010 Proceedings of the 56th IEEE Holm Conference on Electrical Contacts.

[4]  S. McCalmont,et al.  Differentiating series and parallel photovoltaic arc-faults , 2012, 2012 38th IEEE Photovoltaic Specialists Conference.

[5]  Jay Johnson,et al.  Photovoltaic DC Arc Fault Detector testing at Sandia National Laboratories , 2011, 2011 37th IEEE Photovoltaic Specialists Conference.

[6]  Jay Johnson,et al.  Electrical simulations of series and parallel PV arc-faults , 2013, 2013 IEEE 39th Photovoltaic Specialists Conference (PVSC).

[7]  W. Marsden I and J , 2012 .

[8]  S. Gonzalez,et al.  Crosstalk nuisance trip testing of photovoltaic DC arc-fault detectors , 2012, 2012 38th IEEE Photovoltaic Specialists Conference.

[9]  Jay Johnson,et al.  Codes and standards for photovoltaic DC arcfault detection. , 2011 .

[10]  H. Häberlin Arc Detector as an External Accessory Device for PV Inverters for Remote Detection of Dangerous Arcs on the DC Side of PV Plants , 2010 .