Reversible fiber-optic immunosensor measurements☆

Abstract Reversible binding of analyte to antibody is necessary for analytical sensor systems that can continuously measure increases and decreases in analyte concentration. Reversible response occurs when the dissociation rate is sufficiently fast that the analyte will dissociate in a short enough time to permit a rapid re-equilibration to be established in response to a change in analyte concentration. The previously reported phenytoin sensor is based on a homogeneous fluorescence energy-transfer immunoassay and has a reversible response to increases and decreases in phenytoin concentration with a response time of approximately 15 min. The first-order dissociation rate constant for the labeled analyte-antibody complex, phenytoin-B-phycoerythrin (BPE), is 4 × 10 −3 s −1 . Whole antibody and Fab give equivalent sensor performance, which agrees closely with that predicted from a model for the simultaneous equilibrium reactions in the sensor. These results suggest that the antibody binds monovalently to the phenytoin-BPE, and that each antibody binding site acts independently. Optimization of the labeled reactants and reaction conditions results in a sensor which has a dynamic range in the clinically important 1–20 μM concentration range for free phenytoin.

[1]  D. Kranz,et al.  Mechanisms of ligand binding by monoclonal anti-fluorescyl antibodies. , 1982, The Journal of biological chemistry.

[2]  J. Wagner,et al.  Plasma concentrations of diphenylhydantoin, its para-hydroxylated metabolite, and corresponding glucuronide in man. , 1974, Research communications in chemical pathology and pharmacology.

[3]  Richard B. Thompson,et al.  Component Selection for Fiber-Optic Fluorometry , 1990 .

[4]  F. Ligler,et al.  A continuous flow immunoassay for rapid and sensitive detection of small molecules. , 1990, Journal of immunological methods.

[5]  M. Kronick,et al.  Immunoassay techniques with fluorescent phycobiliprotein conjugates. , 1983, Clinical chemistry.

[6]  F. P. Anderson,et al.  Antibody properties for chemically reversible biosensor applications , 1989 .

[7]  F. Ligler,et al.  Detection of Cocaine Using the Flow Immunosensor , 1992 .

[8]  T. W. Smith,et al.  Kinetics in interactions between antibodies and haptens. , 1975, Biochemistry.

[9]  R. Haugland,et al.  Texas Red, a hydrophilic, red-emitting fluorophore for use with fluorescein in dual parameter flow microfluorometric and fluorescence microscopic studies. , 1982, Journal of immunological methods.

[10]  F P Anderson,et al.  Fiber optic immunochemical sensor for continuous, reversible measurement of phenytoin. , 1988, Clinical chemistry.

[11]  J. Herron,et al.  Analysis of heterogeneous dissociation kinetics in polyclonal populations of rabbit anti-fluorescyl-IgG antibodies. , 1983, Molecular immunology.

[12]  Garry A. Rechnitz,et al.  Monoclonal Antibody Biosensor for Antigen Monitoring , 1987 .