Calibration of AC clamp meters

This paper presents a non-invasive method for calibrating AC clamp meters for power and energy measurements. A procedure for determining the ratio error and the phase displacement in a wider frequency range up to 10 kHz is also analyzed. The results of measurements of both types of error for two clamp meters are presented at the end of the paper.

[1]  Karel Draxler,et al.  Use of an inductive divider for AC voltage ratio calibration , 2013, 2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC).

[2]  Eddy So,et al.  A low-current multistage clamp-on current transformer with ratio errors below 50/spl times/10/sup -6/ , 1997 .

[3]  Stuart Harmon,et al.  Final report EUROMET.EM-S11 on EUROMET Projects 473 and 612: Comparison of the measurement of current transformers (CTs) , 2009 .

[4]  Ze Liu,et al.  Digital lock-in amplifier for precision audio frequency bridge , 2012, 2012 Conference on Precision electromagnetic Measurements.

[5]  Pier Paolo Capra,et al.  Traceable Technique to Calibrate Clamp Meters in AC Current From 100 to 1500 A , 2012, IEEE Transactions on Instrumentation and Measurement.

[6]  J. Ramboz,et al.  A highly accurate, hand-held clamp-on current transformer , 1995, Proceedings of 1995 IEEE Instrumentation and Measurement Technology Conference - IMTC '95.

[7]  E. So,et al.  A Current Comparator-Based System for Calibration of AC Shunts at Frequencies Up to Audio Frequencies , 2004, 2004 Conference on Precision Electromagnetic Measurements.

[8]  Gonzalo Aristoy,et al.  On site calibration of current transformers , 2014, 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.

[9]  P. Miljanic,et al.  The development of the current comparator, a high-accuracy A-C ratio measuring device , 1962, Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics.

[10]  Rado Lapuh,et al.  Analysis and improvements of precision coaxial current shunts for direct measurement of ac current , 2011, 2011 IEEE International Instrumentation and Measurement Technology Conference.

[11]  S. Standard GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT , 2006 .

[12]  T. Haeiwa,et al.  Application of MR Element to Clamp-on Type Current Meter , 1992, IEEE Translation Journal on Magnetics in Japan.

[13]  N. L. Kusters,et al.  The Development and Performance of Current Comparators for Audio Frequencies , 1965 .

[14]  Shiyan Ren,et al.  A low-current precision DC, AC and DC/AC clamp-on measurement sensor , 1994, Proceedings of Conference on Precision Electromagnetic Measurements Digest.

[15]  E. So,et al.  High-current high-precision openable-core AC and AC/DC current transformers , 1993 .

[16]  Marian K. Kazimierczuk,et al.  Bandwidth of Current Transformers , 2009, IEEE Transactions on Instrumentation and Measurement.

[17]  E. So,et al.  A low-current multistage clamp-on current transformer with ratio errors below 50 x 10-6 , 1997 .

[18]  Erik Dierikx,et al.  Comparison of AC current ratio standards in the range up to 4 kA , 2010, CPEM 2010.

[19]  J. Bohacek,et al.  Comparison of frequency dependences of resistance standards made from surface mount resistors , 2010, CPEM 2010.

[20]  Rado Lapuh,et al.  Evaluation of a 100 A Current Shunt for the Direct Measurement of AC Current , 2013, IEEE Transactions on Instrumentation and Measurement.

[21]  Eddy So,et al.  A 50 ppm low current multi-stage clamp-on current transformer , 1996, Proceedings of 20th Biennial Conference on Precision Electromagnetic Measurements.

[22]  Jean-Jacques Vandenbussche,et al.  On the Accuracy of Digital Phase Sensitive Detectors Implemented in FPGA Technology , 2014, IEEE Transactions on Instrumentation and Measurement.

[23]  Karel Draxler,et al.  Use of a lock-in amplifier for calibrating an instrument current transformer , 2014, 2014 IEEE International Instrumentation and Measurement Technology Conference (I2MTC) Proceedings.