Multi-frequency static imaging in electrical impedance tomography: Part 1 instrumentation requirements
暂无分享,去创建一个
J. Rosell | P. J. Riu | A. Lozano | R. Pallà-Areny | P. Riu | J. Rosell | A. Lozano | R. Pallà-Areny
[1] D C Barber,et al. Theoretical limits to sensitivity and resolution in impedance imaging. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.
[2] H. Schwan. Electrical properties of tissue and cell suspensions. , 1957, Advances in biological and medical physics.
[3] B. M. Eyuboglu,et al. In vivo imaging of cardiac related impedance changes , 1989, IEEE Engineering in Medicine and Biology Magazine.
[4] H Griffiths,et al. A dual-frequency applied potential tomography technique: computer simulations. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.
[5] Ramon Pallas-Areny,et al. In vivo static imaging for the real and the reactive parts in electrical impedance tomography using multifrequency techniques , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[6] J. Rosell,et al. A parallel data acquisition system for electrical impedance tomography , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.
[7] D. Isaacson. Distinguishability of Conductivities by Electric Current Computed Tomography , 1986, IEEE Transactions on Medical Imaging.
[8] P Rolfe,et al. Aspects of instrumentation design for impedance imaging. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.
[9] J Rosell,et al. Common-mode feedback in electrical impedance tomography. , 1992, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.
[10] J. Webster,et al. A comparison of impedance tomographic reconstruction algorithms. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.
[11] J. C. Newell,et al. Impedance images of the chest , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[12] S Ridella,et al. The frequency dependence of an analytical model of an electrically stimulated biological structure. , 1984, Bioelectromagnetics.
[13] R. Pethig. Dielectric Properties of Biological Materials: Biophysical and Medical Applications , 1984, IEEE Transactions on Electrical Insulation.