Interaction Between Narrowband Power-Line Communication and End-User Equipment

This paper discusses some of the electromagnetic-compatibility issues concerning the use of power lines for communication. Based on a series of measurements performed in a laboratory environment and in the field, five different types of interactions between communication and end-user equipment are distinguished. Measurement examples are shown for several of these types. It is concluded that the creation of a low-impedance path by end-user equipment is the main cause of interference.

[1]  M.H.J. Bollen,et al.  Unintended consequences of limiting high-frequency emission by small end-user equipment , 2006, 2006 IEEE Power Engineering Society General Meeting.

[2]  P.F. Ribeiro,et al.  Limits for Voltage Distortion in the Frequency Range 2 to 9 kHz , 2008, IEEE Transactions on Power Delivery.

[3]  Math Bollen,et al.  Measurement of 182 Hz interharmonics and their impact on relay operation , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[4]  Martin Lundmark,et al.  Harmonics and high-frequency emission by small end-user equipment , 2006 .

[5]  Liangzhong Yao,et al.  Harmonic and interharmonic distortion due to a windpark , 2010, IEEE PES General Meeting.

[6]  Takaya Yamazato,et al.  A mathematical model of noise in narrowband power line communication systems , 2006, IEEE Journal on Selected Areas in Communications.

[7]  Anders Larsson High frequency distortion in power grids due to electronic equipment , 2006 .

[8]  E.O.A Larsson,et al.  Measurement result from 1 to 48 fluorescent lamps in the frequency range 2 to 150 kHz , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[9]  Sarah Rönnberg,et al.  Attenuation and noise level : potential problems with communication via the power grid , 2007 .

[10]  Martin Lundmark,et al.  MEASUREMENT AND ANALYSIS OF HIGH-FREQUENCY CONDUCTED DISTURBANCES , 2007 .

[11]  M.H.J. Bollen,et al.  Equipment currents in the frequency range 9–95 kHz, measured in a realistic environment , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[12]  Olimpo Anaya-Lara,et al.  Reducing unnecessary disconnection of renewable generation from the power system , 2007 .

[13]  Math H. J. Bollen,et al.  Harmonic resonances due to a grid-connected wind farm , 2010, Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010.

[14]  Sarah Rönnberg,et al.  Measurements of interaction between equipment in the frequency range 9 to 95 kHz , 2009 .

[15]  Martin Lundmark,et al.  Distortion of fluorescent lamps in the frequency range 2-150 kHz , 2006 .

[16]  Roger Vines,et al.  Impedance of the Residential Power-Distribution Circuit , 1985, IEEE Transactions on Electromagnetic Compatibility.

[17]  P. B. Eriksen,et al.  Selected studies on offshore wind farm cable connections - challenges and experience of the Danish TSO , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[18]  E O Anders Larsson,et al.  Measurements of High-Frequency (2–150 kHz) Distortion in Low-Voltage Networks , 2010, IEEE Transactions on Power Delivery.

[19]  Martin Lundmark,et al.  HIGH-FREQUENCY COMPONENTS IN THE NEUTRAL AND PROTECTIVE EARTH CURRENTS DUE TO ELECTRONIC EQUIPMENT , 2007 .