Evaluation of the effect of filter apodization for volume PET imaging using the 3-D RP algorithm

We investigated the influence of filter apodization and cutoff frequency on the image quality of volume positron emission tomography (PET) imaging using the three-dimensional reprojection (3-D RP) algorithm. An important parameter in 3-D RP and other filtered backprojection algorithms is the choice of the filter window function. In this study, the Hann, Hamming, and Butterworth low-pass window functions were investigated. For each window, a range of cutoff frequencies was considered. Projection data were acquired by scanning a uniform cylindrical phantom, a cylindrical phantom containing four small lesion phantoms having diameters of 3, 4, 5, and 6 mm and the 3-D Hoffman brain phantom. All measurements were performed using the high-resolution PET camera developed at the M.D. Anderson Cancer Center (MDAPET), University of Texas, Houston, TX. This prototype camera, which is a multiring scanner with no septa, has an intrinsic transaxial resolution of 2.8 mm. The evaluation was performed by computing the noise level in the reconstructed images of the uniform phantom and the contrast recovery of the 6-mm hot lesion in a warm background and also by visually inspecting images, especially those of the Hoffman brain phantom. For this work, we mainly studied the central slices which are less affected by the incompleteness of the 3-D data. Overall, the Butterworth window offered a better contrast-noise performance over the Hann and Hamming windows. For our high statistics data, for the Hann and Hamming apodization functions a cutoff frequency of 0.6-0.8 of the Nyquist frequency resulted in a reasonable compromise between the contrast recovery and noise level and for the Butterworth window a cutoff frequency of 0.4-0.6 of the Nyquist frequency was a reasonable choice. For the low statistics data, use of lower cutoff frequencies was more appropriate.

[1]  Hongdi Li,et al.  Breast cancer imaging studies with a variable field of view PET camera , 1999 .

[2]  E. Hoffman,et al.  3-D phantom to simulate cerebral blood flow and metabolic images for PET , 1990 .

[3]  Wai-Hoi Wong,et al.  Design of a variable field prototype PET camera , 1995 .

[4]  J. Colsher,et al.  Fully-three-dimensional positron emission tomography , 1980, Physics in medicine and biology.

[5]  B. F. Logan,et al.  The Fourier reconstruction of a head section , 1974 .

[6]  Arion F. Chatziioannou,et al.  An investigation of filter choice for filtered back-projection reconstruction in PET , 1997 .

[7]  J. S. Beis,et al.  An automatic method to determine cutoff frequency based on image power spectrum [SPECT] , 1995 .

[8]  Wai-Hoi Wong,et al.  A positron camera detector design with cross-coupled scintillators and quadrant sharing photomultipliers , 1992 .

[9]  Paul Kinahan,et al.  Analytic 3D image reconstruction using all detected events , 1989 .

[10]  C R Crawford,et al.  Oversampled filters for quantitative volumetric PET reconstruction. , 1994, Physics in medicine and biology.

[11]  M. Zambelli,et al.  A 2-dimensional detector decoding study on BGO arrays with quadrant sharing photomultipliers , 1994 .

[12]  S R Cherry,et al.  Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners. , 1992, Physics in medicine and biology.

[13]  Nan Zhang,et al.  Basic imaging performance characteristics of a variable field of view PET camera using quadrant sharing detector design , 1998 .

[14]  Grant T. Gullberg,et al.  Users Manual: Donner Algorithms for Reconstruction Tomography , 1977 .

[15]  Richard E. Carson,et al.  Noise characteristics of 3-D and 2-D PET images , 1998, IEEE Transactions on Medical Imaging.

[16]  Shigeru Yokoyama,et al.  FRONT END ELECTRONICS FOR A VARIABLE FIELD PET CAMERA USING THE PMT-QUADRANT-SHARING DETECTOR ARRAY DESIGN * , 1996 .

[17]  Shigeru Yokoyama,et al.  Electronics for a prototype variable field of view PET camera using the PMT-quadrant-sharing detector array , 1998 .

[18]  D R Gilland,et al.  Determination of the optimum filter function for SPECT imaging. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  S J Riederer,et al.  Ripple suppression during reconstruction in transverse tomography. , 1975, Physics in medicine and biology.