Indices for measurement of harmonic distortion in power systems according to IEC 61000-4-7 standard

Among harmonic distortion indices presented in International Electrotechnical Commission (IET) standard 61000-4-7, only group total harmonic distortion (THDG) can be used for interharmonic pollution analysis. However, existence of interharmonic components around of fundamental frequency may deteriorate accuracy of this index. To solve this problem, two virtual groups according to IEC standard are defined in this study. Then, two new distortion indices are proposed by using virtual groups in equation of THDG index. The new distortion indices are named as: group and subgroup total harmonic distortion and improved THDG. On the basis of various simulation tests and usage of different waveform decomposition methods, it is shown that proposed indices can better show the amount of waveform distortion caused by interharmonics in respect to IEC indices.

[1]  Ozgul Salor,et al.  Kalman filtering based approach for light flicker evaluation of power systems , 2011 .

[2]  Kemal Leblebicioglu,et al.  Interharmonics analysis of power signals with fundamental frequency deviation using Kalman filtering , 2010 .

[3]  Jung-Wook Park,et al.  On Improving Distortion Power Quality Index in Distributed Power Grids , 2013, IEEE Transactions on Smart Grid.

[4]  Kazem Mazlumi,et al.  Harmonic indices assessment by Wavelet Transform , 2011 .

[5]  I. Kamwa,et al.  Extended C37.118.1 PMU Algorithms for Joint Tracking of Fundamental and Harmonic Phasors in Stressed Power Systems and Microgrids , 2014, IEEE Transactions on Power Delivery.

[6]  Alkan Alkaya Unscented Kalman filter performance for closed-loop nonlinear state estimation: a simulation case study , 2014 .

[7]  P. K. Dash,et al.  Fast frequency and harmonic estimation in power systems using a new optimized adaptive filter , 2013 .

[8]  Hsiung Cheng Lin Accurate Harmonic/Interharmonic Estimation Using DFT-Based Group-Harmonics Energy Diffusion Algorithm , 2013, Canadian Journal of Electrical and Computer Engineering.

[9]  Dalibor Brnobic,et al.  Measurement and analysis of harmonic distortion in power distribution systems , 2009 .

[10]  N. Stojković,et al.  The effect of IEC grouping algorithms on frequency domain noise , 2010 .

[11]  Yilu Liu A US-wide power systems frequency monitoring network , 2006 .

[12]  Julio Barros,et al.  Subharmonic measurement using DFT and Wavelet-Packet Transform in an IEC extended framework , 2010 .

[13]  Serhat Seker,et al.  Spectral and statistical analysis for ferroresonance phenomenon in electric power systems , 2012 .

[14]  A. Cataliotti,et al.  Theoretical and experimental comparison of total harmonic distortion factors for the evaluation of harmonic and interharmonic pollution of grid-connected photovoltaic systems , 2006, IEEE Transactions on Power Delivery.

[15]  Andrew J. Roscoe,et al.  Exploring the Relative Performance of Frequency-Tracking and Fixed-Filter Phasor Measurement Unit Algorithms Under C37.118 Test Procedures, the Effects of Interharmonics, and Initial Attempts at Merging P-Class Response With M-Class Filtering , 2013, IEEE Transactions on Instrumentation and Measurement.

[16]  Ganesh K. Venayagamoorthy,et al.  New Power Quality Index in a Distribution Power System by Using RMP Model , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[17]  Prasanta Kundu,et al.  Power quality index based on discrete wavelet transform , 2013 .

[18]  G. Chang,et al.  Measuring power system harmonics and interharmonics by an improved fast Fourier transform-based algorithm , 2008 .

[19]  Julio Barros,et al.  Global method for time–frequency analysis of harmonic distortion in power systems using the wavelet packet transform , 2009 .

[20]  Bidyadhar Subudhi,et al.  Ensemble-Kalman-Filter-Based Power System Harmonic Estimation , 2012, IEEE Transactions on Instrumentation and Measurement.

[21]  Paulo F. Ribeiro,et al.  A new power quality deviation index based on principal curves , 2015 .

[22]  Roberto Langella,et al.  On the Effects of Unbalances, Harmonics and Interharmonics on PLL Systems , 2013, IEEE Transactions on Instrumentation and Measurement.

[23]  V. Singhvi,et al.  Limits for Interharmonics in the 1–100-Hz Range Based on Lamp Flicker Considerations , 2007, IEEE Transactions on Power Delivery.

[24]  Walid G. Morsi,et al.  Novel power quality indices based on wavelet packet transform for non-stationary sinusoidal and non-sinusoidal disturbances , 2010 .

[25]  K. R. Krishnanand,et al.  Fast recursive Gauss-Newton adaptive filter for the estimation of power system frequency and harmonics in a noisy environment , 2011 .

[26]  Vladimir Katic,et al.  Improved analytical expression for calculating total harmonic distortion of PC clusters , 2011 .

[27]  M. Kazerani,et al.  Identification and Measurement of Harmonic Pollution for Radial and Nonradial Systems , 2009, IEEE Transactions on Power Delivery.

[28]  Janusz Mindykowski,et al.  An extended interpretation of THD concept in the wake of ship electric power systems research , 2012 .

[29]  Hsiung-Cheng Lin,et al.  Power Harmonics and Interharmonics Measurement Using Recursive Group-Harmonic Power Minimizing Algorithm , 2012, IEEE Transactions on Industrial Electronics.

[30]  Arturo Garcia-Perez,et al.  Detection and Classification of Single and Combined Power Quality Disturbances Using Neural Networks , 2014, IEEE Transactions on Industrial Electronics.