Dynamic MRI to quantify musculoskeletal motion: A systematic review of concurrent validity and reliability, and perspectives for evaluation of musculoskeletal disorders

Purpose To report evidence for the concurrent validity and reliability of dynamic MRI techniques to evaluate in vivo joint and muscle mechanics, and to propose recommendations for their use in the assessment of normal and impaired musculoskeletal function. Materials and methods The search was conducted on articles published in Web of science, PubMed, Scopus, Academic search Premier, and Cochrane Library between 1990 and August 2017. Studies that reported the concurrent validity and/or reliability of dynamic MRI techniques for in vivo evaluation of joint or muscle mechanics were included after assessment by two independent reviewers. Selected articles were assessed using an adapted quality assessment tool and a data extraction process. Results for concurrent validity and reliability were categorized as poor, moderate, or excellent. Results Twenty articles fulfilled the inclusion criteria with a mean quality assessment score of 66% (±10.4%). Concurrent validity and/or reliability of eight dynamic MRI techniques were reported, with the knee being the most evaluated joint (seven studies). Moderate to excellent concurrent validity and reliability were reported for seven out of eight dynamic MRI techniques. Cine phase contrast and real-time MRI appeared to be the most valid and reliable techniques to evaluate joint motion, and spin tag for muscle motion. Conclusion Dynamic MRI techniques are promising for the in vivo evaluation of musculoskeletal mechanics; however results should be evaluated with caution since validity and reliability have not been determined for all joints and muscles, nor for many pathological conditions.

[1]  J. Udupa,et al.  Mechanics of the ankle and subtalar joints revealed through a 3D quasi-static stress MRI technique. , 2005, Journal of biomechanics.

[2]  S. Hushek,et al.  Dynamic Weight-bearing Cervical Magnetic Resonance Imaging: Technical Review and Preliminary Results , 2004, Southern medical journal.

[3]  Terry K Koo,et al.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. , 2016, Journal Chiropractic Medicine.

[4]  Dwight G Nishimura,et al.  Real‐time imaging of skeletal muscle velocity , 2003, Journal of magnetic resonance imaging : JMRI.

[5]  V. Edgerton,et al.  Muscle synergism during isometric plantarflexion in achilles tendon rupture patients and in normal subjects revealed by velocity-encoded cine phase-contrast MRI. , 2006, Clinical biomechanics.

[6]  David R. Wilson,et al.  Do dynamic‐based MR knee kinematics methods produce the same results as static methods? , 2013, Magnetic resonance in medicine.

[7]  N J Pelc,et al.  Tracking the motion of skeletal muscle with velocity‐encoded MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[8]  K. Alter,et al.  Three-dimensional In Vivo Quantification of Knee Kinematics in Cerebral Palsy , 2008, Clinical orthopaedics and related research.

[9]  D C Yustin,et al.  Determination of the existence of hinge movements of the temporomandibular joint during normal opening by Cine-MRI and computer digital addition. , 1993, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[10]  M. Chung,et al.  Emerging Magnetic Resonance Imaging Technologies for Musculoskeletal Imaging Under Loading Stress: Scope of the Literature , 2011, Annals of Internal Medicine.

[11]  K. Kulig,et al.  Segmental lumbar mobility in individuals with low back pain: in vivo assessment during manual and self-imposed motion using dynamic MRI , 2007, BMC musculoskeletal disorders.

[12]  Scott Tashman,et al.  Abnormal Rotational Knee Motion during Running after Anterior Cruciate Ligament Reconstruction , 2004, The American journal of sports medicine.

[13]  Frances T Sheehan,et al.  Assessing the accuracy and precision of musculoskeletal motion tracking using cine-PC MRI on a 3.0T platform. , 2011, Journal of biomechanics.

[14]  C. Muhle,et al.  [Functional MRI of the femoropatellar joint]. , 1995, Der Radiologe.

[15]  Jens Frahm,et al.  Real-time magnetic resonance imaging of temporomandibular joint dynamics. , 2011 .

[16]  R. Pettigrew Dynamic cardiac MR imaging. Techniques and applications. , 1989, Radiologic clinics of North America.

[17]  M. Eliasziw,et al.  Sample size requirements for reliability studies. , 1987, Statistics in medicine.

[18]  P M Jakob,et al.  Dynamic MRI of the TMJ under physical load. , 2013, Dento maxillo facial radiology.

[19]  F G Shellock,et al.  Patellofemoral joint: identification of abnormalities with active-movement, "unloaded" versus "loaded" kinematic MR imaging techniques. , 1993, Radiology.

[20]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[21]  K. Alter,et al.  Understanding patellofemoral pain with maltracking in the presence of joint laxity: Complete 3D in vivo patellofemoral and tibiofemoral kinematics , 2009, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[22]  C. Muhle,et al.  Motion-triggered cine MR imaging of active joint movement. , 1992, Magnetic resonance imaging.

[23]  J. McGowan,et al.  Errors in search strategies were identified by type and frequency. , 2006, Journal of clinical epidemiology.

[24]  N. Pelc,et al.  Validation of cine phase‐contrast MR imaging for motion analysis , 1995, Journal of magnetic resonance imaging : JMRI.

[25]  S. Pocock,et al.  Strengthening the Reporting of Observational Studies in Epidemiology (STROBE): Explanation and Elaboration , 2007, Epidemiology.

[26]  Frances T Sheehan,et al.  The 3D patellar tendon moment arm: quantified in vivo during volitional activity. , 2007, Journal of biomechanics.

[27]  Frances T Sheehan,et al.  Precise 3D skeletal kinematics using fast phase contrast magnetic resonance imaging , 2003, Journal of magnetic resonance imaging : JMRI.

[28]  P. Bossuyt,et al.  BMC Medical Research Methodology , 2002 .

[29]  Anne Schmitz,et al.  Load-dependent variations in knee kinematics measured with dynamic MRI. , 2013, Journal of biomechanics.

[30]  H. Mehdorn,et al.  Kinematic MR Imaging in Surgical Management of Cervical Disc Disease, Spondylosis and Spondylotic Myelopathy , 1999, Acta radiologica.

[31]  R L Ehman,et al.  Tracking motion with tagged rapid gradient‐echo magnetization‐prepared MR imaging , 1992, Journal of magnetic resonance imaging : JMRI.

[32]  Jong Chul Ye,et al.  Improved k–t BLAST and k–t SENSE using FOCUSS , 2007, Physics in medicine and biology.

[33]  G E Gold,et al.  MRI of weight bearing and movement. , 2012, Osteoarthritis and cartilage.

[34]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[35]  J. Bartko,et al.  On Various Intraclass Correlation Reliability Coefficients , 1976 .

[36]  Ashutosh Kumar Singh,et al.  Global, regional, and national incidence, prevalence, and years lived with disability for 310 diseases and injuries, 1990–2015: a systematic analysis for the Global Burden of Disease Study 2015 , 2016, Lancet.

[37]  M. Eliasziw,et al.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. , 1994, Physical therapy.

[38]  Scott L Delp,et al.  Weight‐bearing MRI of patellofemoral joint cartilage contact area , 2004, Journal of magnetic resonance imaging : JMRI.

[39]  Normalized patellofemoral joint reaction force is greater in individuals with patellofemoral pain. , 2017, Journal of biomechanics.

[40]  J. Weir Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. , 2005, Journal of strength and conditioning research.

[41]  Claudio Rosso,et al.  In vivo glenohumeral translation under anterior loading in an open-MRI set-up. , 2014, Journal of biomechanics.

[42]  R. A. Fellows,et al.  Magnetic resonance imaging for in vivo assessment of three-dimensional patellar tracking. , 2005, Journal of biomechanics.

[43]  V. Edgerton,et al.  Ankle morphology amplifies calcaneus movement relative to triceps surae muscle shortening. , 2013, Journal of applied physiology.

[44]  Constantinos N. Maganaris,et al.  Imaging-based estimates of moment arm length in intact human muscle-tendons , 2004, European Journal of Applied Physiology.

[45]  S. Pocock,et al.  Strengthening the Reporting of Observational Studies in Epidemiology (STROBE): Explanation and Elaboration , 2007, PLoS medicine.

[46]  W. Skalli,et al.  New dynamic three‐dimensional MRI technique for shoulder kinematic analysis , 2014, Journal of magnetic resonance imaging : JMRI.

[47]  Thomas S Buchanan,et al.  A method for measurement of joint kinematics in vivo by registration of 3-D geometric models with cine phase contrast magnetic resonance imaging data. , 2005, Journal of biomechanical engineering.

[48]  E J McWalter,et al.  The effect of load magnitude on three-dimensional patellar kinematics in vivo. , 2010, Journal of biomechanics.

[49]  Juan M. Santos,et al.  Using real‐time MRI to quantify altered joint kinematics in subjects with patellofemoral pain and to evaluate the effects of a patellar brace or sleeve on joint motion , 2009, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[50]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[51]  Samuel R Ward,et al.  Patellofemoral kinematics during weight-bearing and non-weight-bearing knee extension in persons with lateral subluxation of the patella: a preliminary study. , 2003, The Journal of orthopaedic and sports physical therapy.

[52]  Cheng-Chung Lin,et al.  A slice-to-volume registration method based on real-time magnetic resonance imaging for measuring three-dimensional kinematics of the knee. , 2013, Medical physics.

[53]  Richard Kijowski,et al.  Accuracy of model-based tracking of knee kinematics and cartilage contact measured by dynamic volumetric MRI. , 2016, Medical engineering & physics.

[54]  B S Borotikar,et al.  In vivo patellofemoral contact mechanics during active extension using a novel dynamic MRI-based methodology. , 2013, Osteoarthritis and cartilage.

[55]  K. Storheim,et al.  Musculoskeletal disorders and the Global Burden of Disease study , 2014, Annals of the rheumatic diseases.

[56]  F G Shellock,et al.  Quantification of patellar tracking using kinematic MRI , 1998, Journal of magnetic resonance imaging : JMRI.

[57]  Sen Jia,et al.  On analysis of k-t BLAST for dynamic MRI , 2011, 2011 9th IEEE International Conference on Control and Automation (ICCA).

[58]  K. Phan,et al.  Missed cervical disc bulges diagnosed with kinematic magnetic resonance imaging , 2014, European Spine Journal.

[59]  Sylvain Brochard,et al.  Validity and reliability of radiological methods to assess proximal hip geometry in children with cerebral palsy: a systematic review , 2013, Developmental medicine and child neurology.

[60]  N. Pelc,et al.  Measurement of skeletal muscle motion in vivo with phase‐contrast MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[61]  A. Twycross,et al.  Validity and reliability in quantitative studies , 2015, Evidence-Based Nursing.

[62]  Wafa Skalli,et al.  Dynamic Three-Dimensional Shoulder Mri during Active Motion for Investigation of Rotator Cuff Diseases , 2016, PloS one.

[63]  S. Delp,et al.  Image‐based musculoskeletal modeling: Applications, advances, and future opportunities , 2007, Journal of magnetic resonance imaging : JMRI.

[64]  Alan D. Lopez,et al.  The Global Burden of Disease Study , 2003 .

[65]  L. White,et al.  Feasibility study of simultaneous physical examination and dynamic MR imaging of medial collateral ligament knee injuries in a 1.5-T large-bore magnet , 2011, Skeletal Radiology.

[66]  R. Semelka,et al.  MR imaging abbreviations, definitions, and descriptions: a review. , 1999, Radiology.

[67]  M G Pandy,et al.  A non-invasive, 3D, dynamic MRI method for measuring muscle moment arms in vivo: demonstration in the human ankle joint and Achilles tendon. , 2015, Medical engineering & physics.

[68]  M Heller,et al.  Patellar tracking patterns during active and passive knee extension: evaluation with motion-triggered cine MR imaging. , 1993, Radiology.

[69]  Y Zhu,et al.  Three‐dimensional motion tracking with volumetric phase contrast MR velocity imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[70]  V. Edgerton,et al.  Muscle kinematics during isometric contraction: Development of phase contrast and spin tag techniques to study healthy and atrophied muscles , 2004, Journal of magnetic resonance imaging : JMRI.

[71]  Juan M. Santos,et al.  Differences in patellofemoral kinematics between weight‐bearing and non‐weight‐bearing conditions in patients with patellofemoral pain , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[72]  K. Reddy,et al.  Global Burden of Disease Study 2015 provides GPS for global health 2030 , 2016, The Lancet.

[73]  Sylvain Brochard,et al.  Validity and reliability of 3D marker based scapular motion analysis: a systematic review. , 2014, Journal of biomechanics.

[74]  Aart J. Nederveen,et al.  Validation of continuously tagged MRI for the measurement of dynamic 3D skeletal muscle tissue deformation. , 2012, Medical physics.

[75]  J. Babb,et al.  Dynamic Sagittal Half-Fourier Acquired Single-Shot Turbo Spin-Echo MR Imaging of the Temporomandibular Joint: Initial Experience and Comparison with Sagittal Oblique Proton-Attenuation Images , 2007, American Journal of Neuroradiology.

[76]  Bruno D. Zumbo,et al.  Validity and Validation in Social, Behavioral, and Health Sciences , 2014 .

[77]  V. Edgerton,et al.  Asymmetric deformation of contracting human gastrocnemius muscle. , 2012, Journal of applied physiology.

[78]  K. Alter,et al.  Alterations in in vivo knee joint kinematics following a femoral nerve branch block of the vastus medialis: Implications for patellofemoral pain syndrome. , 2012, Clinical biomechanics.

[79]  F E Zajac,et al.  Using cine phase contrast magnetic resonance imaging to non-invasively study in vivo knee dynamics. , 1997, Journal of biomechanics.

[80]  Michael H. Buonocore,et al.  Real-Time Magnetic Resonance Imaging (MRI) during Active Wrist Motion—Initial Observations , 2013, PloS one.

[81]  Kenton R Kaufman,et al.  Error analysis of cine phase contrast MRI velocity measurements used for strain calculation. , 2015, Journal of biomechanics.

[82]  Jong Chul Ye,et al.  k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI , 2009, Magnetic resonance in medicine.

[83]  S. Langner,et al.  Cine MRI: a new approach to the diagnosis of scapholunate dissociation , 2015, Skeletal Radiology.

[84]  K. Siegel,et al.  In Vivo Talocrural and Subtalar Kinematics: A Non-invasive 3D Dynamic MRI Study , 2007, Foot & ankle international.

[85]  L. Stein,et al.  Motion of the patella during walking: a video digital-fluoroscopic study in healthy volunteers. , 1993, AJR. American journal of roentgenology.

[86]  Dan J Stein,et al.  Global, regional, and national incidence, prevalence, and years lived with disability for 301 acute and chronic diseases and injuries in 188 countries, 1990–2013: a systematic analysis for the Global Burden of Disease Study 2013 , 2015, The Lancet.

[87]  Juan M Santos,et al.  Feasibility of using real‐time MRI to measure joint kinematics in 1.5T and open‐bore 0.5T systems , 2008, Journal of magnetic resonance imaging : JMRI.

[88]  Sebastian Kozerke,et al.  MRI temporal acceleration techniques , 2012, Journal of magnetic resonance imaging : JMRI.

[89]  Y. Wang,et al.  Dynamic effects of axial loading on the lumbar spine during magnetic resonance imaging in patients with suspected spinal stenosis. , 2008, Journal of the Formosan Medical Association = Taiwan yi zhi.

[90]  Nadia Magnenat-Thalmann,et al.  Bone Motion Analysis from Dynamic MRI: Acquisition and Tracking , 2004, MICCAI.