Study of Technical Identification of Metal Melted Trace Formed by Electrothermal Effect before Fire to Find Out the Fire Cause
暂无分享,去创建一个
Electrical heater can cause fire if not used properly. In this article, technical identification method of Electrical heater without power cords collected from fire scene is discussed. Using macroscopic analysis, thermoanalysis (DTA), metallographic analysis and simulation experiment, we can ascertain the metal melted traces on the Electrical heater are formed by electrothermal effect before fire. Then we can surely conclude that the Electrical heater caused the fire. And this is a key process during the fire cause investigation.