The cardiac output from blood pressure algorithms trial.

OBJECTIVE The value of different algorithms that estimate cardiac output (CO) by analysis of a peripheral arterial blood pressure (ABP) waveform has not been definitively identified. In this investigation, we developed a testing data set containing a large number of radial ABP waveform segments and contemporaneous reference CO by thermodilution measurements, collected in an intensive care unit (ICU) patient population during routine clinical operations. We employed this data set to evaluate a set of investigational algorithms, and to establish a public resource for the meaningful comparison of alternative CO-from-ABP algorithms. DESIGN A retrospective comparative analysis of eight investigational CO-from-ABP algorithms using the Multiparameter Intelligent Monitoring in Intensive Care II database. SETTING Mixed medical/surgical ICU of a university hospital. PATIENTS A total of 120 cases. INTERVENTIONS None. MEASUREMENTS CO estimated by eight investigational CO-from-ABP algorithms, and CO(TD) as a reference. MAIN RESULTS All investigational methods were significantly better than mean arterial pressure (MAP) at estimating direction changes in CO(TD). Only the formula proposed by Liljestrand and Zander in 1928 was a significantly better quantitative estimator of CO(TD) compared with MAP (95% limits-of-agreement with CO(TD): -1.76/+1.41 L/min versus -2.20/+1.82 L/min, respectively; p < 0.001, per the Kolmogorov-Smirnov test). The Liljestrand method was even more accurate when applied to the cleanest ABP waveforms. Other investigational algorithms were not significantly superior to MAP as quantitative estimators of CO. CONCLUSIONS Based on ABP data recorded during routine intensive care unit (ICU) operations, the Liljestrand and Zander method is a better estimator of CO(TD) than MAP alone. Our attempts to fully replicate commercially-available methods were unsuccessful, and these methods could not be evaluated. However, the data set is publicly and freely available, and developers and vendors of CO-from-ABP algorithms are invited to test their methods using these data.

[1]  J. Roelandt,et al.  Stroke volume from central aortic pressure? A critical assessment of the various formulae as to their clinical value , 1975, Basic Research in Cardiology.

[2]  The measurement of relative stroke volume from aortic pulse contour of pulse pressure. , 1968, Vascular diseases.

[3]  James Xin Sun,et al.  Cardiac output estimation using arterial blood pressure waveforms , 2006 .

[4]  O Gödje,et al.  Continuous, Less Invasive, Hemodynamic Monitoring in Intensive Care After Cardiac Surgery , 1998, The Thoracic and cardiovascular surgeon.

[5]  W. Zong,et al.  An automated, Web-enabled and searchable database system for archiving electrogram and related data from implantable cardioverter defibrillators , 2002, Computers in Cardiology.

[6]  N. T. Smith,et al.  A simple device for the continuous measurement of cardiac output. Its model basis and experimental verification , 1983 .

[7]  H. Bazett,et al.  AN ANALYSIS OF THE TIME‐RELATIONS OF ELECTROCARDIOGRAMS. , 1997 .

[8]  G.B. Moody,et al.  The impact of the MIT-BIH Arrhythmia Database , 2001, IEEE Engineering in Medicine and Biology Magazine.

[9]  J. A. Herd,et al.  Arterial pressure pulse contours during hemorrhage in anesthetized dogs. , 1966, Journal of applied physiology.

[10]  R. Pearse,et al.  Equipment review: An appraisal of the LiDCO™plus method of measuring cardiac output , 2004, Critical care.

[11]  J R Jansen,et al.  Computation of aortic flow from pressure in humans using a nonlinear, three-element model. , 1993, Journal of applied physiology.

[12]  R.G. Mark,et al.  A signal abnormality index for arterial blood pressure waveforms , 2006, 2006 Computers in Cardiology.

[13]  Reinhard Friedl,et al.  Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability , 2002, Critical care medicine.

[14]  M. Bourgeois,et al.  Continuous Determination of Beat‐to‐Beat Stroke Volume from Aortic Pressure Pulses in the Dog , 1976, Circulation research.

[15]  W. Bancroft,et al.  Velocity of blood flow and stroke volume obtained from the pressure pulse. , 1959, The Journal of clinical investigation.

[16]  G. Liljestrand,et al.  Vergleichende Bestimmungen des Minutenvolumens des Herzens beim Menschen mittels der Stickoxydulmethode und durch Blutdruckmessung , 1928 .

[17]  Thomas Heldt Continuous blood pressure-derived cardiac output monitoring--should we be thinking long term? , 2006, Journal of applied physiology.

[18]  E H WOOD,et al.  Quantitation of beat-to-beat changes in stroke volume from the aortic pulse contour in man. , 1953, Journal of applied physiology.

[19]  D G Altman,et al.  Comparing two methods of clinical measurement: a personal history. , 1995, International journal of epidemiology.

[20]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[21]  A. Schutte,et al.  Sensitivity of the Finometer device in detecting acute and medium-term changes in cardiovascular function , 2003, Blood pressure monitoring.

[22]  Roger G. Mark,et al.  An open-source algorithm to detect onset of arterial blood pressure pulses , 2003, Computers in Cardiology, 2003.

[23]  L. Skovgaard,et al.  Thermodilution cardiac output – are three injections enough? , 2004, Acta anaesthesiologica Scandinavica.

[24]  R G Mark,et al.  MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring , 2002, Computers in Cardiology.

[25]  A critique: relationship of the time derivative of pressure to blood flow , 1965 .

[26]  A. Rhodes,et al.  Arterial Pulse Power Analysis: The LiDCOℳ plus System , 2005 .

[27]  S. Morris,et al.  Do the Finapres and Colin radial artery tonometer measure the same blood pressure changes following deflation of thigh cuffs? , 2003, Physiological measurement.

[28]  K. Wesseling,et al.  Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution. , 1999, Anesthesiology.

[29]  J. Jansen,et al.  The thermodilution method for the clinical assessment of cardiac output , 1995, Intensive Care Medicine.

[30]  N. Kouchoukos,et al.  Estimation of Stroke Volume in the Dog by a Pulse Contour Method , 1970, Circulation research.