A comparison of monopolar and bipolar recording techniques for examining the patterns of responses for electromyographic amplitude and mean power frequency versus isometric torque for the vastus lateralis muscle

The purpose of the present study was to compare monopolar and bipolar recording techniques for the patterns of responses and mean values for absolute and normalized electromyographic (EMG) amplitude and mean power frequency (MPF) versus isometric torque for the vastus lateralis muscle. Ten healthy men (mean+/-S.D. age=23.6+/-3.0 years; body weight=80.9+/-15.6 kg) volunteered to perform submaximal to maximal isometric muscle actions of the dominant leg extensors. Monopolar and bipolar surface EMG signals were detected simultaneously from the vastus lateralis with an eight-channel linear electrode array. The results indicated that in 70-80% of the cases, monopolar and bipolar recording techniques resulted in the same patterns of responses for absolute and normalized EMG amplitude and MPF versus isometric torque. There were, however, differences between the two techniques for mean absolute EMG amplitude and MPF values, but not for the normalized values. Thus, these results supported the practice of normalization, and suggested that comparisons can be made between monopolar and bipolar recording methods for the patterns of responses and mean values for normalized (but not absolute) EMG amplitude and MPF versus isometric torque.

[1]  T Abe,et al.  Fascicle length of leg muscles is greater in sprinters than distance runners. , 2000, Medicine and science in sports and exercise.

[2]  Isak Gath,et al.  Techniques for Improving the Selectivity of Electromyographic Recordings , 1976, IEEE Transactions on Biomedical Engineering.

[3]  R L Lieber,et al.  Clinical significance of skeletal muscle architecture. , 2001, Clinical orthopaedics and related research.

[4]  D. Stegeman,et al.  Multichannel surface EMG: Basic aspects and clinical utility , 2003, Muscle & nerve.

[5]  Joseph P Weir,et al.  MECHANOMYOGRAPHIC AND ELECTROMYOGRAPHIC RESPONSES OF THE VASTUS MEDIALIS MUSCLE DURING ISOMETRIC AND CONCENTRIC MUSCLE ACTIONS , 2005, Journal of strength and conditioning research.

[6]  D. Stegeman,et al.  The motor unit potential distribution over the skin surface and its use in estimating the motor unit location. , 1997, Acta physiologica Scandinavica.

[7]  R Merletti,et al.  Repeatability of surface EMG variables during voluntary isometric contractions of the biceps brachii muscle. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[8]  G L Soderberg,et al.  A guide for use and interpretation of kinesiologic electromyographic data. , 2000, Physical therapy.

[9]  Jiri Silny,et al.  Spatial Filtering of Noninvasive Multielectrode EMG: Part I-Introduction to Measuring Technique and Applications , 1987, IEEE Transactions on Biomedical Engineering.

[10]  T. Moritani,et al.  Reexamination of the relationship between the surface integrated electromyogram (IEMG) and force of isometric contraction. , 1978, American journal of physical medicine.

[11]  H. Devries,et al.  "Efficiency of electrical activity" as a physiological measure of the functional state of muscle tissue. , 1968, American journal of physical medicine.

[12]  Travis W. Beck,et al.  The effects of innervation zone on electromyographic amplitude and mean power frequency during incremental cycle ergometry , 2006, Journal of Neuroscience Methods.

[13]  K. Tucker,et al.  A new method to estimate signal cancellation in the human maximal M-wave , 2005, Journal of Neuroscience Methods.

[14]  P. L. Parmeggiani,et al.  Quantitative analysis of short term deprivation and recovery of desynchronized sleep in cats. , 1980, Electroencephalography and clinical neurophysiology.

[15]  P. Zipp,et al.  Effect of electrode parameters on the bandwidth of the surface e.m.g. power-density spectrum , 1978, Medical and Biological Engineering and Computing.

[16]  D. Farina,et al.  The linear electrode array: a useful tool with many applications. , 2003, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[17]  C. D. De Luca,et al.  Myoelectric signal versus force relationship in different human muscles. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[18]  L.H. Lindstrom,et al.  Interpretation of myoelectric power spectra: A model and its applications , 1977, Proceedings of the IEEE.

[19]  Travis W. Beck,et al.  The influence of electrode placement over the innervation zone on electromyographic amplitude and mean power frequency versus isokinetic torque relationships , 2007, Journal of Neuroscience Methods.

[20]  G. Melchiorri,et al.  A method for positioning electrodes during surface EMG recordings in lower limb muscles , 2004, Journal of Neuroscience Methods.

[21]  Roberto Merletti,et al.  Electromyography. Physiology, engineering and non invasive applications , 2005 .

[22]  Roberto Merletti,et al.  MultiChannel Techniques for Information Extraction from the Surface EMG , 2004 .

[23]  T. Moritani,et al.  Motor unit activity and surface electromyogram power spectrum during increasing force of contraction , 2004, European Journal of Applied Physiology and Occupational Physiology.

[24]  H. Hermens,et al.  European recommendations for surface electromyography: Results of the SENIAM Project , 1999 .

[25]  Carlo J. De Luca,et al.  The Use of Surface Electromyography in Biomechanics , 1997 .

[26]  D F Stegeman,et al.  Near- and far-fields: source characteristics and the conducting medium in neurophysiology. , 1997, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[27]  D. Ha Quantitative electromyographic investigation of the spasm theory of muscle pain. , 1966 .

[28]  R Merletti,et al.  Non-invasive assessment of motor unit properties with linear electrode arrays. , 1997, Electroencephalography and clinical neurophysiology. Supplement.

[29]  E. Pedhazur Multiple Regression in Behavioral Research: Explanation and Prediction , 1982 .

[30]  D. Stegeman,et al.  Far-field evoked potential components induced by a propagating generator: computational evidence. , 1987, Electroencephalography and clinical neurophysiology.

[31]  Steen Andreassen,et al.  Recording from a Single Motor Unit During Strong Effort , 1978, IEEE Transactions on Biomedical Engineering.

[32]  Joseph P Weir,et al.  The effect of the estimated innervation zone on EMG amplitude and center frequency. , 2007, Medicine and science in sports and exercise.

[33]  Roberto Merletti,et al.  The extraction of neural strategies from the surface EMG. , 2004, Journal of applied physiology.

[34]  B Gerdle,et al.  The behaviour of the mean power frequency of the surface electromyogram in biceps brachii with increasing force and during fatigue. With special regard to the electrode distance. , 1990, Electromyography and clinical neurophysiology.

[35]  Travis W. Beck,et al.  Comparison of the fast Fourier transform and continuous wavelet transform for examining mechanomyographic frequency versus eccentric torque relationships , 2006, Journal of Neuroscience Methods.

[36]  Joseph P Weir,et al.  The effects of electrode placement and innervation zone location on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis muscle. , 2008, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[37]  Joseph P Weir,et al.  Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[38]  T. Fukunaga,et al.  Determination of fascicle length and pennation in a contracting human muscle in vivo. , 1997, Journal of applied physiology.

[39]  J. Basmajian Muscles Alive—their functions revealed by electromyography , 1963 .

[40]  Joseph P Weir,et al.  The effects of interelectrode distance on electromyographic amplitude and mean power frequency during isokinetic and isometric muscle actions of the biceps brachii. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[41]  Roberto Merletti,et al.  Detection and Conditioning of Surface EMG Signals , 2004 .

[42]  H. Kwatny,et al.  An application of signal processing techniques to the study of myoelectric signals. , 1970, IEEE transactions on bio-medical engineering.

[43]  T. Housh,et al.  The effects of interelectrode distance on electromyographic amplitude and mean power frequency during incremental cycle ergometry , 2006, Journal of Neuroscience Methods.

[44]  D. Farina,et al.  Geometrical factors in surface EMG of the vastus medialis and lateralis muscles. , 2000, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[45]  E. Kaplan Muscles Alive. Their Functions Revealed by Electromyography. J. V. Basmajian. Baltimore, The Williams and Wilkins Co., 1962. $8.50 , 1962 .