Development of a Biconcave Mobile‐Bearing Lumbar Total Disc Arthroplasty Concept Using Finite Element Analysis and Design Optimization
暂无分享,去创建一个
[1] Gun Choi,et al. CHARITÉ Versus ProDisc: A Comparative Study of a Minimum 3-Year Follow-up , 2007, Spine.
[2] A Shirazi-Adl,et al. Analysis of large compression loads on lumbar spine in flexion and in torsion using a novel wrapping element. , 2006, Journal of biomechanics.
[3] S. Kurtz,et al. Prediction of multiaxial mechanical behavior for conventional and highly crosslinked UHMWPE using a hybrid constitutive model. , 2003, Biomaterials.
[4] L. Claes,et al. Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants , 1998, European Spine Journal.
[5] Guoan Li,et al. Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity. , 2016, Journal of biomechanics.
[6] Thomas Zweig,et al. Design concepts in lumbar total disc arthroplasty , 2008, European Spine Journal.
[7] S. Kurtz,et al. Total Disc Replacement Positioning Affects Facet Contact Forces and Vertebral Body Strains , 2008, Spine.
[8] S. Kurtz,et al. The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements. , 2012, Seminars in spine surgery.
[9] L. Pimenta,et al. The importance of the anterior longitudinal ligament in lumbar disc arthroplasty: 36-Month follow-up experience in extreme lateral total disc replacement , 2012, International Journal of Spine Surgery.
[10] L. Felli,et al. Lumbar total disc arthroplasty: outdated surgery or here to stay procedure? A systematic review of current literature , 2017, Journal of Orthopaedics and Traumatology.
[11] Antonius Rohlmann,et al. Effect of multilevel lumbar disc arthroplasty on spine kinematics and facet joint loads in flexion and extension: a finite element analysis , 2012, European Spine Journal.
[12] Marc-Antoine Rousseau,et al. Disc arthroplasty design influences intervertebral kinematics and facet forces. , 2006, The spine journal : official journal of the North American Spine Society.
[13] H. Wilke,et al. Do in vivo kinematic studies provide insight into adjacent segment degeneration? A qualitative systematic literature review , 2015, European Spine Journal.
[14] Shih-Hao Chen,et al. Biomechanical comparison between lumbar disc arthroplasty and fusion. , 2009, Medical engineering & physics.
[15] A. Patwardhan,et al. What Is the Correlation of In Vivo Wear and Damage Patterns With In Vitro TDR Motion Response? , 2008, Spine.
[16] A. Messac,et al. The normalized normal constraint method for generating the Pareto frontier , 2003 .
[17] Lutz Claes,et al. Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment. , 2007, Clinical biomechanics.
[18] S. Kurtz,et al. Lumbar Total Disc Replacement Impingement Sensitivity to Disc Height Distraction, Spinal Sagittal Orientation, Implant Position, and Implant Lordosis , 2012, Spine.
[19] J. Fisher,et al. Wear characteristics of an unconstrained lumbar total disc replacement under a range of in vitro test conditions , 2015, Journal of biomedical materials research. Part B, Applied biomaterials.
[20] L. Claes,et al. The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis. , 2008, Clinical biomechanics.
[21] R. Mobbs,et al. Anterior Longitudinal Ligament Reconstruction to Reduce Hypermobility of Cervical and Lumbar Disc Arthroplasty , 2017, Asian spine journal.
[22] Ryan Willing,et al. Quantifying the competing relationship between durability and kinematics of total knee replacements using multiobjective design optimization and validated computational models. , 2012, Journal of biomechanics.
[23] Manohar M Panjabi,et al. Effects of Charité Artificial Disc on the Implanted and Adjacent Spinal Segments Mechanics Using a Hybrid Testing Protocol , 2005, Spine.
[24] F. Galbusera,et al. Biomechanical studies on cervical total disc arthroplasty: a literature review. , 2008, Clinical biomechanics.
[25] Ryan Willing,et al. Design optimization of a total knee replacement for improved constraint and flexion kinematics. , 2011, Journal of biomechanics.
[26] I. Y. Kim,et al. Adaptive weighted-sum method for bi-objective optimization: Pareto front generation , 2005 .
[27] D. Ku,et al. Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc. , 2006, Journal of biomechanics.
[28] Antonius Rohlmann,et al. A non-optimized follower load path may cause considerable intervertebral rotations. , 2010, Journal of biomechanics.
[29] S. Salzmann,et al. Lumbar disc replacement surgery—successes and obstacles to widespread adoption , 2017, Current Reviews in Musculoskeletal Medicine.
[30] A Rohlmann,et al. Applying a follower load delivers realistic results for simulating standing. , 2009, Journal of biomechanics.
[31] The Implications of Constraint in Lumbar Total Disc Replacement , 2003, Journal of spinal disorders & techniques.
[32] Hendrik Schmidt,et al. The effect of different design concepts in lumbar total disc arthroplasty on the range of motion, facet joint forces and instantaneous center of rotation of a L4-5 segment , 2009, European Spine Journal.
[33] Jung-Hee Lee,et al. Biomechanical changes of the lumbar segment after total disc replacement : charite(r), prodisc(r) and maverick(r) using finite element model study. , 2010, Journal of Korean Neurosurgical Society.
[34] Ryan Willing,et al. Three dimensional shape optimization of total knee replacements for reduced wear , 2009 .
[35] M M Panjabi,et al. Human Lumbar Vertebrae: Quantitative Three-Dimensional Anatomy , 1992, Spine.
[36] H. Wilke,et al. Limitations of current in vitro test protocols for investigation of instrumented adjacent segment biomechanics: critical analysis of the literature , 2015, European Spine Journal.
[37] Bryan W Cunningham,et al. Biomechanical Evaluation of Total Disc Replacement Arthroplasty: An In Vitro Human Cadaveric Model , 2003, Spine.
[38] A Rohlmann,et al. Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together. , 2014, Journal of biomechanics.
[39] Paul Park,et al. Adjacent Segment Disease after Lumbar or Lumbosacral Fusion: Review of the Literature , 2004, Spine.
[40] A. Studer. Nucleus prosthesis: a new concept , 2002, European Spine Journal.
[41] John E. Dennis,et al. Normal-Boundary Intersection: A New Method for Generating the Pareto Surface in Nonlinear Multicriteria Optimization Problems , 1998, SIAM J. Optim..
[42] A Shirazi-Adl,et al. Biomechanics of the Lumbar Spine in Sagittal/Lateral Moments , 1994, Spine.
[43] Helmut D. Link,et al. History, design and biomechanics of the LINK SB Charité artificial disc , 2002, European Spine Journal.
[44] S. Kurtz,et al. Polyethylene wear and rim fracture in total disc arthroplasty. , 2007, The spine journal : official journal of the North American Spine Society.
[45] G. J. Verkerke,et al. Geometry of the Intervertebral Volume and Vertebral Endplates of the Human Spine , 2009, Annals of Biomedical Engineering.
[46] Avinash G Patwardhan,et al. Response of Charité total disc replacement under physiologic loads: prosthesis component motion patterns. , 2005, The spine journal : official journal of the North American Spine Society.
[47] A. Patwardhan,et al. A follower load increases the load-carrying capacity of the lumbar spine in compression. , 1999, Spine.
[48] Olivier Ethgen,et al. Health-related quality of life in total hip and total knee arthroplasty. A qualitative and systematic review of the literature. , 2004, The Journal of bone and joint surgery. American volume.
[49] Robert Gunzburg,et al. Spine arthroplasty: a historical review , 2002, European Spine Journal.
[50] M. Panjabi,et al. Articular Facets of the Human Spine Quantitative Three‐Dimensional Anatomy , 1993, Spine.
[51] A. R.,et al. Review of literature , 1951, American Potato Journal.