Allogeneic human tissue-engineered blood vessel.

BACKGROUND Arterial bypass graft implantation remains the primary therapy for patients with advanced cardiovascular disease; however, there is no available synthetic small-diameter vascular graft. METHODS Tissue-engineered vessels were grown from human smooth muscle cells that were seeded on a biodegradable scaffold using a biomimetic perfusion system. The human tissue-engineered vessels (hTEV) were decellularized by a two-step process using a combination of detergents and hypertonic solutions. The mechanical characteristics were assessed by suture retention strength and burst pressure. The decellularized hTEV were implanted as aortic interpositional grafts in nude rats to evaluate in vivo performance as an arterial graft over a 6-week period. RESULTS The human tissue-engineered structure formed a vessel composed of smooth muscle cells and the extracellular matrix proteins, including collagen. After decellularization, the collagen matrix remained intact while the cellular components were removed. The mechanical strength of the hTEV after decellularization was similar to human vein in vitro, with a burst pressure of 1,567 ± 384 mm Hg (n = 3) versus 1,680 ± 307 mm Hg for human saphenous vein. The hTEVs had a high patency rate (four of five grafts) without evidence of rupture or aneurysm over a 6-week period as an aortic interpositional graft in a nude rat model. Histologic analysis showed a thin neointima with a confluent endothelium and a subendothelial layer of smooth muscle cells on the explanted tissue-engineered vessels. Transmission electron microscopy on the explanted tissue demonstrated elastin formation in the neointima and intact residual collagen fibers from the tissue-engineered vessel. CONCLUSIONS The hTEV had a high patency rate and remained mechanically stable as an aortic interpositional graft in a nude rat. The vessel supported the growth of a neointima with endothelial cells and smooth muscle cells. The host remodeling suggested the engineered matrix had a positive effect to create a regenerated vascular graft.

[1]  L. Niklason,et al.  Novel utilization of serum in tissue decellularization. , 2010, Tissue engineering. Part C, Methods.

[2]  Robert Gurny,et al.  Degradation and Healing Characteristics of Small-Diameter Poly(&egr;-Caprolactone) Vascular Grafts in the Rat Systemic Arterial Circulation , 2008, Circulation.

[3]  S. Edwards,et al.  Pulmonary autograft versus homograft replacement of the aortic valve: a prospective randomized trial. , 1997, The Journal of thoracic and cardiovascular surgery.

[4]  Marcin Maruszewski,et al.  Effectiveness of haemodialysis access with an autologous tissue-engineered vascular graft: a multicentre cohort study , 2009, The Lancet.

[5]  R Langer,et al.  Functional arteries grown in vitro. , 1999, Science.

[6]  M. Kassem,et al.  Blood vessels engineered from human cells , 2005, The Lancet.

[7]  T. Matsuda,et al.  Canine endothelial progenitor cell-lined hybrid vascular graft with nonthrombogenic potential. , 2003, The Journal of thoracic and cardiovascular surgery.

[8]  Robert Langer,et al.  Biodegradable Polymer Scaffolds for Tissue Engineering , 1994, Bio/Technology.

[9]  G. Korbutt,et al.  Glutaraldehyde-Fixed Bioprosthetic Heart Valve Conduits Calcify and Fail From Xenograft Rejection , 2006, Circulation.

[10]  Yi Hong,et al.  In vivo assessment of a tissue-engineered vascular graft combining a biodegradable elastomeric scaffold and muscle-derived stem cells in a rat model. , 2010, Tissue engineering. Part A.

[11]  Laura E Niklason,et al.  Decellularized tissue-engineered blood vessel as an arterial conduit , 2011, Proceedings of the National Academy of Sciences.

[12]  T. Murohara,et al.  Evaluation of Compliance and Stiffness of Decellularized Tissues as Scaffolds for Tissue-Engineered Small Caliber Vascular Grafts Using Intravascular Ultrasound , 2006, ASAIO journal.

[13]  Seung‐Woo Cho,et al.  Small-Diameter Blood Vessels Engineered With Bone Marrow–Derived Cells , 2005, Annals of surgery.

[14]  L. Niklason,et al.  Small‐diameter human vessel wall engineered from bone marrow‐derived mesenchymal stem cells (hMSCs) , 2008, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[15]  N. L'Heureux,et al.  Human tissue-engineered blood vessels for adult arterial revascularization , 2007, Nature Medicine.

[16]  R Langer,et al.  Morphologic and mechanical characteristics of engineered bovine arteries. , 2001, Journal of vascular surgery.

[17]  W. Klepetko,et al.  Alpha‐Gal on bioprostheses: xenograft immune response in cardiac surgery , 2005, European journal of clinical investigation.

[18]  E Bell,et al.  A blood vessel model constructed from collagen and cultured vascular cells. , 1986, Science.

[19]  S. Hoff,et al.  Cryopreserved Saphenous Vein Allografts for Below‐Knee Lower Extremity Revascularization , 1994, Annals of surgery.

[20]  H. Lukoff,et al.  Ovine panel reactive antibody assay of HLA responsivity to allograft bioengineered vascular scaffolds. , 2005, The Journal of thoracic and cardiovascular surgery.

[21]  J. Tomaszewski,et al.  Human saphenous vein allograft bypass grafts: immune response. , 1998, Journal of vascular surgery.

[22]  L. Choe,et al.  Immunoproteomic identification of bovine pericardium xenoantigens. , 2008, Biomaterials.

[23]  F A Auger,et al.  A completely biological tissue‐engineered human blood vessel , 1998, FASEB journal : official publication of the Federation of American Societies for Experimental Biology.

[24]  Vikas Prabhakar,et al.  Decellularized native and engineered arterial scaffolds for transplantation. , 2003, Cell transplantation.

[25]  Narutoshi Hibino,et al.  Late-term results of tissue-engineered vascular grafts in humans. , 2010, The Journal of thoracic and cardiovascular surgery.

[26]  B. Ballermann,et al.  Chronic in vitro shear stress stimulates endothelial cell retention on prosthetic vascular grafts and reduces subsequent in vivo neointimal thickness. , 1999, Journal of vascular surgery.

[27]  Anthony Atala,et al.  Functional small-diameter neovessels created using endothelial progenitor cells expanded ex vivo , 2001, Nature Medicine.

[28]  Stephen F Badylak,et al.  Immune response to biologic scaffold materials. , 2008, Seminars in Immunology.

[29]  G. White,et al.  Animal models for the assessment of novel vascular conduits. , 2010, Journal of vascular surgery.