Characteristics of compact detectors based on pixellated NaI(Tl) crystal arrays

Results are presented on the preliminary evaluation of the pixellated NaI(Tl) crystal arrays for use in high-resolution small field-of-view gamma cameras. A prototype detector was developed using the pixellated NaI(Tl) arrays attached to a 5" diameter position-sensitive photomultiplier tube (PSPMT). Two 5.3 cm square pixellated NaI(Tl) crystal arrays from Saint-Gobain with pixel sizes of 1/spl times/1/spl times/6 mm and 2/spl times/2/spl times/6 mm were tested. A conventional charge division readout using a resistive chain was used with the PSPMT. The detector was tested using a uniform flood source and a /spl sim/0.8 mm diameter collimated Tc-99m source. The collimated source was scanned over both crystal arrays. The performance characteristics including spatial resolution, energy resolution and the ability to resolve the pixellated crystal elements were determined. The response of the pixellated detector was also measured. With the conventional resistive-chain readout the individual pixels were well resolved for the 2 mm pixellated crystal array but not for the 1 mm pixellated crystal array from the images of a uniform flood source. An average FWHM of 1.4 mm was obtained with a 0.8 mm diameter pencil-beam over the active crystal area for both crystal arrays. The energy resolutions from the individual pixels were 10.8% and 10.0% at 140-keV photon energy for the 1 mm and 2 mm pixellated crystals, respectively. Our study indicates that using conventional resistive-chain readout, a compact detector comprised of a pixellated NaI(Tl) crystal array and a 5" diameter PSPMT at best can achieve a spatial resolution of /spl sim/1.1 mm. We conclude that the use of pixellated crystal arrays with /spl sim/1.5 mm pixel element is likely to be an optimal choice for the combination of this PSPMT with resistive chain readout technology for development of high resolution small field-of-view gamma cameras.

[1]  Horst Halling,et al.  Compact high resolution detector for small animal SPECT , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[2]  Horst Halling,et al.  Compact high resolution detector for small animal SPECT , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[3]  A. G. Weisenberger,et al.  High spatial resolution gamma imaging detector based on a 5" diameter R3292 Hamamatsu PSPMT , 1997 .

[4]  Hidehiro Kume,et al.  Position Sensitive Photomultiplier Tubes for Scintillation Imaging , 1986, IEEE Transactions on Nuclear Science.

[5]  Andrew G. Weisenberger,et al.  High resolution detector modules based on NaI(Tl) arrays for small animal imaging , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[6]  Margaret S. Saha,et al.  Design features and performance of a CsI(Na) array based gamma camera for small animal gene research , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.