SUMMARY
The system performance of a ground source heat pump (HP) system is determined by the HP characteristics itself and by the thermal interaction between the ground and its borehole heat exchanger (BHE). BHE performance is strongly influenced by the thermal properties of the ground formation, grouting material, and BHE type. Experimental investigations on different BHE types and grouting materials were carried out in Belgium. Its performances were investigated with in situ thermal response tests to determine the thermal conductivity (λ) and borehole resistance (Rb). The line-source method was used to analyze the results, and the tests showed the viability of the method. The main goal was to determine the thermal borehole resistance of BHEs, including the effect of the grouting material. The ground thermal conductivity was measured as 2.21 W m−1 K−1, a high value for the low fraction of water-saturated sand and the high clay content at the test field. The borehole resistance for a standard coaxial tube with cement–bentonite grouting varied from 0.344 to 0.162 K W−1 m for the double U-tube with cement–bentonite mixture (52% reduction). Grouting material based on purely a cement–bentonite mixture results in a high thermal borehole resistance. Addition of sand to the mixture leads to a better performance. The use of thermally enhanced grouts did not improve the performance significantly in comparison with only a low-cost grouting material as sand. Potential future applications are possible in our country using a mobile testing device, such as characteristics, standardization, quality control, and certification for drilling companies and ground source HP applications, and in situ research for larger systems. Copyright © 2011 John Wiley & Sons, Ltd.
[1]
A Aittomäki,et al.
Effect of soil type and moisture content on ground heat pump performance
,
1998
.
[2]
Yusuf Ali Kara,et al.
Experimental performance evaluation of a closed‐loop vertical ground source heat pump in the heating mode using energy analysis method
,
2007
.
[3]
A. Busso,et al.
First in situ determination of ground and borehole thermal properties in Latin America
,
2004
.
[4]
John W. Lund,et al.
Direct application of geothermal energy : 2005 worldwide review
,
2005
.
[5]
Mortaza Yari,et al.
Performance assessment of a horizontal‐coil geothermal heat pump
,
2007
.
[6]
Z. Fang,et al.
Heat transfer analysis of boreholes in vertical ground heat exchangers
,
2003
.
[7]
Daniel Pahud,et al.
Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ
,
2001
.
[8]
Daniel Pahud,et al.
Numerical evaluation of thermal response tests
,
2007
.
[9]
Arif Hepbasli,et al.
Experimental study of a closed loop vertical ground source heat pump system
,
2003
.
[10]
Ladislaus Rybach,et al.
Current status of ground source heat pumps and underground thermal energy storage in Europe
,
2003
.
[11]
A. Hepbasli,et al.
Experimental investigation of the performance of a solar‐assisted ground‐source heat pump system for greenhouse heating
,
2005
.