An ultrasonic technique for the measurement of the elastic moduli of human cornea.

In the hopes of reducing the unpredictability associated with refractive surgical procedures and ultimately improving surgical techniques, many investigators have attempted to determine the elastic moduli of the cornea. Techniques such as stress-strain tests of corneal strips and the measurement of mercury drop displacement in a whole eye under increasing pressure have resulted in a range of values for Young's modulus from 10(5) to 10(7) Nm-2. Both of these methods are limited because these mechanical tests cannot be performed in the physiological state and because of the large amount of force applied during testing. We used an ultrasonic technique to determine the elastic moduli of the human cornea. Two groups of six corneas prepared under different conditions (in saline and in dextran) were examined separately and the shear waves were generated and detected in these 12 human eye bank eyes. All the waveforms were digitized and saved in files of binary format. Fast Fourier transformation (FFT) was applied to calculate the speed and attenuation of the shear wave. Using the resulting wave speeds and attenuation coefficients, the Young's moduli of the corneal samples were calculated as (5.3 +/- 1.1) x 10(6) Nm-2 and (2.0 +/- 1.0) x 10(7) Nm-2 for cornea samples prepared in saline and in dextran at 2.25 MHz, respectively.

[1]  D. Bray Nondestructive Evaluation , 2018 .

[2]  R. Marks,et al.  Evaluating the predictability of radial keratotomy. , 1985, Ophthalmology.

[3]  H. Tchah,et al.  Human cadaver corneal thinning for experimental refractive surgery. , 1989, Refractive & corneal surgery.

[4]  J. Holladay,et al.  Prospective evaluation of radial keratotomy. Photokeratoscope corneal topography. , 1988, Ophthalmology.

[5]  M. Lynn,et al.  Factors affecting outcome and predictability of radial keratotomy in the PERK Study. , 1987, Archives of ophthalmology.

[6]  G. W. Nyquist,et al.  Rheology of the cornea: experimental techniques and results. , 1968, Experimental eye research.

[7]  E. Madsen,et al.  Ultrasonic shear wave properties of soft tissues and tissuelike materials. , 1983, The Journal of the Acoustical Society of America.

[8]  D. Maurice,et al.  The mechanical properties of the rabbit and human cornea. , 1986, Journal of biomechanics.

[9]  R. E. Smith,et al.  Radial keratotomy in fresh human cadaver eyes. , 1981, Ophthalmology.

[10]  T M Burke,et al.  Preliminary results for shear wave speed of sound and attenuation coefficients from excised specimens of human breast tissue. , 1990, Ultrasonic imaging.

[11]  W D O'Brien,et al.  Frequency dependence of tissue attenuation measured by acoustic microscopy. , 1989, The Journal of the Acoustical Society of America.

[12]  D. Hoeltzel,et al.  Strip Extensiometry for Comparison of the Mechanical Response of Bovine, Rabbit, and Human Corneas , 1992 .

[13]  G. Briggs,et al.  The elastic microstructure of various tissues. , 1989, The Journal of the Acoustical Society of America.

[14]  P R Greene,et al.  Comparison of mechanical properties of keratoconus and normal corneas. , 1982, Experimental eye research.

[15]  J. Ferry Viscoelastic properties of polymers , 1961 .

[16]  H. Oxlund,et al.  Biomechanical properties of keratoconus and normal corneas. , 1980, Experimental eye research.

[17]  G. Briggs,et al.  Wideband acoustic microscopy of tissue , 1989 .