Miniature mass analyzers

Increased efforts are being made to develop miniature mass spectrometers, including those which are hand-portable, and to retain the performance characteristics of traditional laboratory instruments as much as possible in the miniature instruments. This review of miniature mass analyzers emphasizes analytical performance and compares the relative merits of each type of miniature mass analyzer. Miniature instruments discussed include sector, Wien filter, time-of-flight, linear quadrupole, quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometers, as well as combinations of and variations on these major types. Special considerations that apply to small mass analyzers are noted and suggestions are made regarding the possible future development of this field. Copyright 2000 John Wiley & Sons, Ltd.

[1]  V. Garkanian,et al.  Miniature, high-resolution, quadrupole mass-spectrometer array , 1997 .

[2]  R. March An Introduction to Quadrupole Ion Trap Mass Spectrometry , 1997 .

[3]  M. M. Ahmad,et al.  Fabrication of a microengineered quadrupole electrostatic lens , 1996 .

[4]  R. Cooks,et al.  A miniature cylindrical quadrupole ion trap:  simulation and experiment. , 1998, Analytical Chemistry.

[5]  T. Matsuo,et al.  A Space Time-of-Flight Mass Spectrometer for Exobiologically-Oriented Applications , 1999 .

[6]  Mahadeva P. Sinha,et al.  Development of a miniaturized, light‐weight magnetic sector for a field‐portable mass spectrograph , 1991 .

[7]  I. Amster,et al.  Fourier Transform Mass Spectrometry , 1996 .

[8]  Robert M. Young,et al.  CHEMICAL SENSING USING NONOPTICAL MICROELECTROMECHANICAL SYSTEMS , 1999 .

[9]  Mark G. Blamire,et al.  Development of a portable time-of-flight membrane inlet mass spectrometer for environmental analysis , 1998 .

[10]  R. Edmondson,et al.  High-resolution Mass Spectrometry and Accurate Mass Measurements with Emphasis on the Characterization of Peptides and Proteins by Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry , 1997 .

[11]  W. E. Reynolds,et al.  Recent improvements in and analytical applications of advanced ion trap technology , 1984 .

[12]  M. Guilhaus,et al.  PERFECT TIMING : TIME-OF-FLIGHT MASS SPECTROMETRY , 1997 .

[13]  On‐site environmental and in situ process analysis by mass spectrometry , 1996 .

[14]  M. A. Carlson,et al.  A TIME-OF-FLIGHT MINI-MASS SPECTROMETER : AEROSOL COLLECTION, CAPTURE, ANDLOAD-LOCK SYSTEM , 1999 .

[15]  M. Guilhaus,et al.  Special feature: Tutorial. Principles and instrumentation in time‐of‐flight mass spectrometry. Physical and instrumental concepts , 1995 .

[16]  J. Michael Ramsey,et al.  Electron impact ionization in a microion trap mass spectrometer , 1999 .

[17]  J. Michael Ramsey,et al.  Micro ion trap mass spectrometry , 1999 .

[18]  M. P. Sinha,et al.  Development of a miniaturized gas chromatograph-mass spectrometer with a microbore capillary column and an array detector , 1991 .

[19]  R. Yost,et al.  Tandem-in-space and tandem-in-time mass spectrometry: triple quadrupoles and quadrupole ion traps , 1990 .

[20]  Andrew F. Cheng,et al.  Laser time-of-flight mass spectrometry for space , 2000 .

[21]  R. Cotter,et al.  Miniaturized time-of-flight mass spectrometer for peptide and oligonucleotide analysis. , 1999, Journal of mass spectrometry : JMS.

[22]  R. J. Ferran,et al.  High‐pressure effects in miniature arrays of quadrupole analyzers for residual gas analysis from 10−9 to 10−2 Torr , 1996 .

[23]  R. Hites,et al.  Design and performance of a plasma-source mass spectrograph , 1997 .

[24]  Chad Lembke,et al.  Development of an underwater mass-spectrometry system for in situ chemical analysis , 1999 .

[25]  T. J. Tate,et al.  Design of a microengineered electrostatic quadrupole lens , 1998 .

[26]  M. M. Ahmad,et al.  Initial results for a quadrupole mass spectrometer with a silicon micromachined mass filter , 1998 .

[27]  E. Hoffmann Tandem mass spectrometry: A primer , 1996 .

[28]  R. J. Ferran,et al.  MINIATURE QUADRUPOLE ARRAYS FOR RESIDUAL AND PROCESS GAS ANALYSIS , 1999 .

[29]  Robert E. Ellefson,et al.  Miniature quadrupole residual gas analyzer for process monitoring at milliTorr pressures , 1998 .

[30]  G. Glish,et al.  Multiple stages of mass spectrometry in a quadrupole ion trap mass spectrometer : prerequisites , 1991 .

[31]  Timothy J. Cornish,et al.  Miniature Time-of-Flight Mass Spectrometer for a Field-Portable Biodetection System , 1999 .

[32]  R. Cooks,et al.  Instrumentation, applications, and energy deposition in quadrupole ion-trap tandem mass spectrometry , 1987 .

[33]  G. Petzold,et al.  Surface microstructure/miniature mass spectrometer:.processing and applications , 1998 .

[34]  Yu. V. Chichagov,et al.  Design and testing of a portable magnetic mass spectrometer , 1997 .

[35]  P. H. Hemberger,et al.  Operation of a quadrupole ion trap mass spectrometer to achieve high mass/charge ratios , 1991 .

[36]  R. Cotter,et al.  High-order kinetic energy focusing in an end cap reflectron time-of-flight mass spectrometer. , 1997, Analytical chemistry.