Two-point method for T1 estimation with optimized gradient-echo sequence.

Relaxation times estimation methods play a central role in various problems, such as magnetic resonance (MR) hardware calibration, tissue characterization, or temperature measurement. Previous studies have proposed optimization criteria to estimate the relaxation time T1 faster than with a multipoint method leading to two-point methods. In this paper, the class of optimized two-point methods is extended to gradient-echo (GE) sequence offering new advantages over spin-echo (SE) or inversion recovery (IR) sequences. Two GE acquisitions, with optimal flip angles theta1 and theta2 minimizing both the total scan time and the variance in the computed T1 image were applied to estimate T1, and the results were compared with those of SE sequence with optimized paired repetition times T(R1) and T(R2). First, phantom studies were carried out with five tissue-like samples on a 0.5T scanner. Then in vivo, human brain T1 image were calculated using both optimized GE and SE two-point methods. More precise T1 GE estimates than those for SE were found thanks to high signal-to-noise ratio (SNR) per unit of time, but with a small bias. These results also concern the temperature variation measurement methods, based on T1 estimation. Preliminary experimental data for temperature measurement are given.

[1]  D. Durham,et al.  The state of water in biological systems as studied by proton and deuterium relaxation. , 1975, Biochimica et biophysica acta.

[2]  T. Nelson,et al.  Temperature dependence of proton relaxation times in vitro. , 1987, Magnetic resonance imaging.

[3]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[4]  O Henriksen,et al.  In vivo quantification of the unidirectional influx constant for Gd‐DTPA diffusion across the myocardial capillaries with MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.

[5]  W. Semmler,et al.  NMR relaxation times T1 and T2 of water in plasma from patients with lung carcinoma: Correlation of T2 with blood sedimentation rate , 1987, Magnetic resonance in medicine.

[6]  A Oatridge,et al.  Further observations on the measurement of tissue T1 to monitor temperature in vivo by MRI , 1994, Magnetic resonance in medicine.

[7]  A. S. Hall,et al.  Measurement of changes in tissue temperature using MR imaging. , 1986, Journal of computer assisted tomography.

[8]  J. P. Jones,et al.  Foundations of Medical Imaging , 1993 .

[9]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[10]  A. Haase,et al.  Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging , 1990, Magnetic resonance in medicine.

[11]  J. Cuppen,et al.  RLSQ: T1, T2, and ρ calculations, combining ratios and least squares , 1987 .

[12]  D L Parker,et al.  Temperature distribution measurements in two-dimensional NMR imaging. , 1983, Medical physics.

[13]  D. Drost,et al.  Optimization of signal‐to‐noise ratio in calculated T1 images derived from two spin‐echo images , 1986, Magnetic resonance in medicine.

[14]  R. Kurland Strategies and tactics in NMR imaging relaxation time measurements. I. Minimizing relaxation time errors due to image noise—the ideal case , 1985, Magnetic resonance in medicine.

[15]  B. Fung Non-freezable water and spin-lattice relaxation time in muscle containing a growing tumor. , 1974, Biochimica et biophysica acta.

[16]  In vivo T1 values from guinea pig brain depend on body temperature , 1992, Magnetic resonance in medicine.

[17]  R Deichmann,et al.  Quantification of T1 values by SNAPSHOT-FLASH NMR imaging , 1992 .

[18]  Dennis L. Parker,et al.  Applications of NMR Imaging in Hyperthermia: An Evaluation of the Potential for Localized Tissue Heating and Noninvasive Temperature Monitoring , 1984, IEEE Transactions on Biomedical Engineering.