Determination of critical load for flange buckling in concentrically loaded pultruded columns

Abstract Physical testing and theoretical methods to determine the critical local flange buckling load in concentric pultruded columns are presented. Knowledge of this critical load for wide flange profiles is required in a new universal column design procedure. Because there are too few test results for other profile sizes only the standard 203×203×9.53 mm (8×8×3/8 in.) profile is considered. Reasons are given to explain why the 14 data points give buckling loads between 307 and 406 kN. To obtain a test result corresponding to the true physical situation the minimum column length should be four half-wavelengths of the local instability. The true critical load is about 360 kN. Presented are nine closed form equations that can be used to predict the critical load for the local instability. To use these equations effectively, it is shown that the elastic constants of the flange material must be those of the profile being analysed. Numerical methods, and their closed form equations, that include the rotational stiffness at the web–flange connection are shown to be reasonably accurate. However, without direct access to the software they are difficult to apply, and these equations are therefore unsuitable for application in the preparation of universal design guidance. A simpler equation that predicts the buckling load to within 4% of 360 kN is therefore recommended.

[1]  David W. Scott,et al.  SHORT-TERM BEHAVIOR AND DESIGN OF FIBER-REINFORCED POLYMERIC SLENDER MEMBERS UNDER AXIAL COMPRESSION , 1997 .

[2]  Edoardo Cosenza,et al.  Local buckling curves for the design of FRP profiles , 2000 .

[3]  John S. Tomblin,et al.  Local buckling experiments on FRP columns , 1994 .

[4]  J. T. Mottram,et al.  Physical testing for concentrically loaded columns of pultruded glass fibre reinforced plastic profile , 2003 .

[5]  Ever J. Barbero,et al.  Prediction and measurement of the post-critical behavior of fiber-reinforced composite columns , 1998 .

[6]  John S. Tomblin,et al.  A phenomenological design equation for FRP columns with interaction between local and global buckling , 1994 .

[7]  Lawrence C. Bank,et al.  Buckling of orthotropic plates with free and rotationally restrained unloaded edges , 1996 .

[8]  Ever J. Barbero,et al.  Experimental verification of buckling-mode interaction in intermediate-length composite columns , 2000 .

[9]  M Pecce,et al.  EXPERIMENTAL EVALUATION OF BENDING AND TORSIONAL DEFORMABILITY OF FRP PULTRUDED BEAMS , 1996 .

[10]  Lawrence C. Bank,et al.  Failure of Web-Flange Junction in Postbuckled Pultruded I-Beams , 1999 .

[11]  Ioannis G. Raftoyiannis,et al.  Local Buckling of FRP Beams and Columns , 1993 .

[12]  Soon Jong Yoon Local buckling of pultruded I-shape columns , 1993 .

[13]  Ever J. Barbero,et al.  Beam-Column Design Equations for Wide-Flange Pultruded Structural Shapes , 1999 .

[14]  Julio F. Davalos,et al.  LOCAL BUCKLING OF COMPOSITE FRP SHAPES BY DISCRETE PLATE ANALYSIS , 2001 .

[15]  Hans H. Bleich,et al.  Buckling strength of metal structures , 1952 .

[16]  J. Clarke Structural design of polymer composites : EUROCOMP design code and handbook , 1996 .