Narrow angles and angle closure: anatomic reasons for earlier closure of the superior portion of the iridocorneal angle.

OBJECTIVE To quantitatively investigate the ultrasound biomicroscopic features of eyes with asymmetric narrowing of the iridocorneal angles. METHODS Asymmetric angles were defined as those differing by 2 or more Shaffer grades between the superior and inferior angles. We performed ultrasound biomicroscopy on 18 eyes in 18 patients. Measurements of the following were made: the angle recess area, the triangular area bordered by the anterior iris surface, the corneal endothelium, and a line drawn from 750 microm anterior to the scleral spur; the y-intercept, the estimated angle opening distance at the level of the scleral spur; acceleration, which describes how rapidly the angle widens from the iris root; trabecular-ciliary process distance, the distance between the trabecular meshwork and the ciliary body at 500 microm anterior to the scleral spur; and angle recess-iris insertion distance, the distance between the apex of the angle recess and the iris insertion on the ciliary body face. RESULTS In the superior angle, 11 eyes developed appositional closure, 10 with B-type (apposition beginning at the iris root) and 1 with S-type (apposition beginning at the line of Schwalbe). Four eyes also had apposition inferiorly (1 B-type and 3 S-types). The y-intercept, angle recess areas, trabecular-ciliary process distance, and angle recess-iris insertion distance were significantly smaller in the superior quadrant. S-type angles predominated in the inferior angle, and B-type angles did in the superior angle, indicating a more posterior insertion of the iris in the wider inferior angles. CONCLUSIONS Asymmetry in eyes with narrow angles occurs because of differences in iris insertion position on the ciliary body face and from asymmetry of the ciliary body position.

[1]  L. Vijaya,et al.  Anterior Chamber Angle Assessment Using Gonioscopy and Ultrasound Biomicroscopy , 2003, Japanese Journal of Ophthalmology.

[2]  佐久間毅 Appositional Angle Closure in Eyes with Narrow Angles: An Ultrasound Biomicroscopic Study , 1997 .

[3]  F. Foster,et al.  Clinical use of ultrasound biomicroscopy. , 1991, Ophthalmology.

[4]  C Tello,et al.  Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability. , 1994, Investigative ophthalmology & visual science.

[5]  R. Ritch Plateau Iris Is Caused by Abnormally Positioned Ciliary Processes , 1992 .

[6]  F. Foster,et al.  An ultrasound biomicroscopic dark-room provocative test. , 1995, Ophthalmic surgery.

[7]  A. Iwase,et al.  Prevalence of appositional angle closure determined by ultrasonic biomicroscopy in eyes with shallow anterior chambers. , 2005, Ophthalmology.

[8]  M. Lowe Primary Angle Closure Glaucoma: A Review of Ocular Biometry , 1977 .

[9]  C. Phillips,et al.  CLOSED-ANGLE GLAUCOMA SIGNIFICANCE OF SECTORAL VARIATIONS IN ANGLE DEPTH* , 1956, The British journal of ophthalmology.

[10]  F. Foster,et al.  Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. , 1992, American journal of ophthalmology.

[11]  R. Pandey,et al.  Ultrasound Biomicroscopy in the Subtypes of Primary Angle Closure Glaucoma , 2005, Journal of glaucoma.

[12]  H. Ishikawa,et al.  Angle recess area decreases with age in normal Japanese. , 2000, Japanese journal of ophthalmology.

[13]  C. Phillips,et al.  Early angle-closure glaucoma. Distribution of iridotrabecular contact and response to pilocarpine. , 1973, Archives of ophthalmology.

[14]  Y. Kitazawa,et al.  [Observation of the chamber angle in primary angle-closure glaucoma with an ultrasound biomicroscope]. , 1995, Nippon Ganka Gakkai zasshi.

[15]  R. Ritch,et al.  Role of ultrasound biomicroscopy in the differentiation of block glaucomas , 1998, Current Opinion in Ophthalmology.

[16]  G. Marchini,et al.  Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma. , 1998, Ophthalmology.

[17]  R Ritch,et al.  Quantitative assessment of the anterior segment using ultrasound biomicroscopy. , 2000, Current opinion in ophthalmology.

[18]  F. S. Foster,et al.  Ultrasound Biomicroscopy of the Eye , 1994, Springer New York.

[19]  R Ritch,et al.  Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width. , 1999, Japanese journal of ophthalmology.