Inductively-Coupled Frequency Tuning and Impedance Matching in HTS-Based NMR Probes

Nuclear magnetic resonance (NMR) probes based on high-temperature superconducting (HTS) resonators have demonstrated significant gains in detection sensitivity. However, the widespread acceptance of this technology has been limited by some unresolved issues including the mechanical unreliability of the moveable inductive loops used to adjust tuning and matching. In order to improve reliability, we propose to implement frequency tuning and impedance matching of HTS resonators using fixed inductively coupled loops and variable capacitors. By analyzing the loss mechanisms associated with inductive loops, we predict that using a superconducting inductive loop for tuning and matching will not only improve the reliability of HTS probes, but also provide improvements in sensitivity.

[1]  A. Saito,et al.  Electromagnetic Evaluation of HTS RF Coils for Nuclear Magnetic Resonance , 2015, IEEE Transactions on Applied Superconductivity.

[2]  Saikat Saha,et al.  Design, construction, and validation of a 1-mm triple-resonance high-temperature-superconducting probe for NMR. , 2006, Journal of magnetic resonance.

[3]  A. Saito,et al.  Development of HTS Pickup Coils for 700-MHz NMR: Resonance Frequency Tuning Using a Sapphire Plate , 2015, IEEE Transactions on Applied Superconductivity.

[4]  R. Withers,et al.  Development of a ¹³C-optimized 1.5-mm high temperature superconducting NMR probe. , 2013, Journal of magnetic resonance.

[5]  T. Mareci,et al.  In vivo 1H magnetic resonance imaging and spectroscopy of the rat spinal cord using an inductively‐coupled chronically implanted RF coil , 2001, Magnetic resonance in medicine.

[6]  R. Withers,et al.  Development of a 1H-13C Dual-Optimized NMR Probe Based on Double-Tuned High Temperature Superconducting Resonators , 2016, IEEE Transactions on Applied Superconductivity.

[7]  High Temperature Superconducting Radio Frequency Coils for NMR Spectroscopy and Magnetic Resonance Imaging , 2000, cond-mat/0004346.

[8]  R. Withers,et al.  Microsample Cryogenic Probes: Technology and Applications , 2013 .

[9]  L Darrasse,et al.  Optimization of NMR receiver bandwidth by inductive coupling. , 1992, Magnetic resonance imaging.

[10]  J. S. Leigh,et al.  Wireless implanted magnetic resonance probes for in vivo NMR , 1986 .

[11]  P. Styles,et al.  A high-resolution NMR probe in which the coil and preamplifier are cooled with liquid helium. 1984. , 1984, Journal of magnetic resonance.

[12]  M. Tatoulian,et al.  Implanted, inductively-coupled, radiofrequency coils fabricated on flexible polymeric material: application to in vivo rat brain MRI at 7 T. , 2012, Journal of magnetic resonance.

[13]  J. Hyde,et al.  Inductive (flux linkage) coupling to local coils in magnetic resonance imaging and spectroscopy , 1986 .

[14]  Chantal Rémy,et al.  An inductively coupled, series-tuned NMR probe , 1985 .