Performance Analysis of Blood Culture by an Automated Blood Culture System at a Tertiary Care Teaching Hospital in South India

This Prospective study analyses culture result of 134 blood culture samples received in microbiology laboratory during a five months period between October 2014 and February 2015. We have documented time required for the culture to become positive, time at which culture could be considered negative and the spectrum of isolated organismsms including their antimicrobial susceptibility patterns. The specimens were processed by using automated system BacT/Alert 3D/60. Microorganism’s identification was performed by routine conventional and automated identification system and antibiotic susceptibility testing was done by Kirby bauer disk diffusion method. The mean detection time for isolates was 14.5 +/- 5.7 hours. Among organisms isolated included were Gram positive bacteria, Gram negative bacteria and yeasts with 22 (16.4%), 14 (10.4%) and 19 (14.2%) respectively. All our cultures were positive within 34 hours.

[1]  Y. Samuel,et al.  Quality assurance in blood culture: A retrospective study of blood culture contamination rate in a tertiary hospital in Nigeria , 2014, Nigerian medical journal : journal of the Nigeria Medical Association.

[2]  A. Shamsuzzaman,et al.  Bacteriological profiles of Blood culture isolates by BacT/ALERT 3D automated system , 2012 .

[3]  J. Stalpers,et al.  An evaluation of three processing methods and the effect of reduced culture times for faster direct identification of pathogens from BacT/ALERT blood cultures by MALDI-TOF MS , 2011, European Journal of Clinical Microbiology & Infectious Diseases.

[4]  D. V. van Zyl,et al.  Comparison of the VersaTREK blood culture system against the Bactec9240 system in patients with suspected bloodstream infections , 2011, Annals of Clinical Microbiology and Antimicrobials.

[5]  M. Clementi,et al.  The Era of Molecular and Other Non-Culture-Based Methods in Diagnosis of Sepsis , 2010, Clinical Microbiology Reviews.

[6]  A. Setia,et al.  Clinical and Bacteriological Profiles of Blood Culture Positive Sepsis in Newborns , 2009 .

[7]  P. Bourbeau,et al.  Routine Incubation of BacT/ALERT FA and FN Blood Culture Bottles for More than 3 Days May Not Be Necessary , 2005, Journal of Clinical Microbiology.

[8]  D. Hospenthal,et al.  Direct Comparison of the BACTEC 9240 and BacT/ALERT 3D Automated Blood Culture Systems for Candida Growth Detection , 2004, Journal of Clinical Microbiology.

[9]  T. Shwe,et al.  Blood culture isolates from children admitted to Medical Unit III, Yangon Children's Hospital, 1998. , 2002, The Southeast Asian journal of tropical medicine and public health.

[10]  V. Ramachandran,et al.  Bacteriological analysis of blood culture isolates from neonates in a tertiary care hospital in India. , 2002, Journal of health, population, and nutrition.

[11]  R. Black,et al.  Typhoid fever in Bangladesh: implications for vaccination policy. , 2001, The Pediatric infectious disease journal.

[12]  W. Dunne,et al.  Four-day incubation period for blood culture bottles processed with the Difco ESP blood culture system , 1997, Journal of clinical microbiology.

[13]  M. Weinstein,et al.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia , 1997, Journal of clinical microbiology.

[14]  E. Bryce,et al.  Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospital , 1995, Journal of clinical microbiology.

[15]  M. Weinstein,et al.  Controlled evaluation of BacT/alert standard anaerobic and FAN anaerobic blood culture bottles for the detection of bacteremia and fungemia , 1995, Journal of clinical microbiology.

[16]  R. Auckenthaler,et al.  Comparison of BacT/Alert with Signal blood culture system , 1995, Journal of clinical microbiology.

[17]  P. C. Migneault,et al.  Time to detection of positive BacT/Alert blood cultures and lack of need for routine subculture of 5- to 7-day negative cultures , 1992, Journal of clinical microbiology.

[18]  Michael L Wilson,et al.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems , 1992, Journal of clinical microbiology.

[19]  J. E. Turner,et al.  BacT/Alert: an automated colorimetric microbial detection system , 1990, Journal of clinical microbiology.