Development of a New Generic Analytical Modeling of AC Coupling Losses in Cable-in-Conduit Conductors

Coupling losses induced in cable-in-conduit conductors (CICC) when subject to a time-varying magnetic field are a major issue commonly encountered in large fusion tokamaks (e.g., JT-60SA, ITER, DEMO). The knowledge of these losses is crucial to determine the stability of CICC but is yet difficult to achieve analytically (thus in a short computation time) given the specific and complex architecture of these conductors although numerical solutions such as THELMA and JACKPOT already exist. In an attempt to ease the resolution of this problem, we have previously presented a theoretical generic study of a group of elements twisted together (representing a cabling stage of a CICC) and derived the analytical expression of its coupling losses. We have now extended this study to a two cabling stage conductor by establishing an analytical model to calculate its coupling losses as function of its effective features. In a second part, we compare our results to these of THELMA and JACKPOT on geometries representing ITER CS and JT-60SA TF conductors. Finally, we have set up a specific algorithm to reconstruct strand trajectories from X-ray images and have extracted the effective geometrical parameters of a JT-60SA TF conductor. Our next objective is then to extract its effective electrical parameters from interstrand resistivity measurements to be able to compare the coupling losses predicted by our analytical model with those measured within the SULTAN facility.

[1]  Arend Nijhuis,et al.  Coupling loss time constants in full-size Nb3Sn CIC model conductors for fusion magnets , 1996 .

[2]  L. Zani,et al.  A macroscopic model for coupling current losses in cables made of multistages of superconducting strands and its experimental validation , 2010 .

[3]  R. Zanino,et al.  Numerical Analysis of the ITER TF Conductor Samples in SULTAN With the THELMA Code , 2009, IEEE Transactions on Applied Superconductivity.

[4]  B. Turck,et al.  Losses in superconducting composites under high rate pulsed transverse field , 1979 .

[5]  Arend Nijhuis,et al.  Validation of a strand-level CICC-joint coupling loss model , 2012 .

[6]  Alexandre Louzguiti Magnetic screening currents and coupling losses induced in superconducting magnets for thermonuclear fusion , 2017 .

[7]  L. Zani,et al.  Accurate 3D modeling of Cable in Conduit Conductor type superconductors by X-ray microtomography , 2015 .

[8]  Arend Nijhuis,et al.  JackPot: A novel model to study the influence of current non-uniformity and cabling patterns in cable-in-conduit conductors , 2010 .

[9]  B. Turck,et al.  Coupling losses in various outer normal layers surrounding the filament bundle of a superconducting composite , 1979 .

[10]  Arend Nijhuis,et al.  Contact resistance and coupling loss in cable-in-conduit of Cr plated Nb3Sn strands , 1998 .

[11]  Alexandre Torre,et al.  AC Coupling Losses in CICCs: Analytical Modeling at Different Stages , 2017, IEEE Transactions on Applied Superconductivity.

[12]  Jr. W. Carr,et al.  Longitudinal and transverse field losses in multifilament superconductors , 1977 .

[13]  G. H. Morgan,et al.  Theoretical Behavior of Twisted Multicore Superconducting Wire in a Time‐Varying Uniform Magnetic Field , 1970 .

[14]  K Kizu,et al.  Design of JT-60SA Magnets and Associated Experimental Validations , 2011, IEEE Transactions on Applied Superconductivity.

[15]  Arend Nijhuis,et al.  Analysis of ITER NbTi and Nb3Sn CICCs experimental minimum quench energy with JackPot, MCM and THEA models , 2017 .

[16]  Arend Nijhuis,et al.  Parametric study on coupling loss in subsize ITER Nb/sub 3/Sn cabled specimen , 1996 .

[17]  G. Ries,et al.  AC-losses in multifilamentary superconductors at technical frequencies , 1977 .

[18]  A. Campbell A general treatment of losses in multifilamentary superconductors , 1982 .

[19]  D. Ciazynski,et al.  A model for calculating a.c. losses in multistage superconducting cables , 1996 .

[20]  Herman Ten Kate AC Losses and Magnet Research , 1994 .

[21]  Arend Nijhuis,et al.  Change of interstrand contact resistance and coupling loss in various prototype ITER NbTi conductors with transverse loading in the Twente Cryogenic Cable Press up to 40,000 cycles , 2004 .

[22]  D. Ciazynski,et al.  Development of an Analytical-Oriented Extensive Model for AC Coupling Losses in Multilayer Superconducting Composites , 2016, IEEE Transactions on Applied Superconductivity.

[23]  Arnaud Devred,et al.  Analysis of AC Losses in the ITER Central Solenoid Insert Coil , 2017, IEEE Transactions on Applied Superconductivity.

[24]  W. J. Carr Conductivity, permeability, and dielectric constant in a multifilament superconductor , 1975 .

[25]  M. Breschi,et al.  Electromagnetic Modeling of the Jacket in Cable-in-Conduit Conductors , 2008, IEEE Transactions on Applied Superconductivity.

[26]  Arend Nijhuis,et al.  THELMA code electromagnetic model of ITER superconducting cables and application to the ENEA Stability Experiment , 2006 .