Heart Monitoring Garments Using Textile Electrodes for Healthcare Applications

We measured the electrical activity signals of the heart through vital signs monitoring garments that have textile electrodes in conductive yarns while the subject is in stable and dynamic motion conditions. To measure the electrical activity signals of the heart during daily activities, four types of monitoring garment were proposed. Two experiments were carried out as follows: the first experiment sought to discover which garment led to the least displacement of the textile electrode from its originally intended location on the wearer’s body. In the second, we measured and compared the electrical activity signals of the heart between the wearer’s stable and dynamic motion states. The results indicated that the most appropriate type of garment sensing-wise was the “cross-type”, and it seems to stabilize the electrode’s position more effectively. The value of SNR of ECG signals for the “cross-type” garment is the highest. Compared to the “chest-belt-type” garment, which has already been marketed commercially, the “cross-type” garment was more efficient and suitable for heart activity monitoring.

[1]  P M Rautaharju,et al.  The effect of modified limb electrode positions on electrocardiographic wave amplitudes. , 1980, Journal of electrocardiology.

[2]  Rita Paradiso,et al.  A wearable health care system based on knitted integrated sensors , 2005, IEEE Transactions on Information Technology in Biomedicine.

[3]  Theoretic Analysis of the Influence of Heart‐Dipole Eccentricity on Limb Leads, Wilson Central‐Terminal Voltage and the Frontal‐Plane Vectorcardiogram , 1953, Circulation research.

[4]  X. Tao Wearable Electronics and Photonics , 2005 .

[5]  P M Rautaharju,et al.  The missing waveform and diagnostic information in the standard 12 lead electrocardiogram. , 1981, Journal of electrocardiology.

[6]  Elsayed Z Soliman Recording electrocardiograms using 3-limb lead cables instead of the standard 4: a modification to minimize incorrect electrode placements. , 2008, Journal of electrocardiology.

[7]  Z. Z. Zao A geometric study of the relationship between limb leads and cardiac vector in the frontal plane. , 1960, American heart journal.

[8]  Ernest Frank,et al.  General Theory of Heart‐Vector Projection , 1954 .

[9]  H. C. Burger,et al.  HEART-VECTOR AND LEADS. , 1946, British heart journal.

[10]  K. Shimada,et al.  A Comparative Evaluation Between Conditions of the Wrist Band Capacitively-Coupled ECG Recording through Signal-to-Noise Ratio , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  J. Vanhala,et al.  Textile Electrodes in ECG Measurement , 2007, 2007 3rd International Conference on Intelligent Sensors, Sensor Networks and Information.

[12]  Lucy E. Dunne,et al.  Evaluating the Impact of Garment Structure on Wearable Sensor Performance , 2007, 2007 11th IEEE International Symposium on Wearable Computers.

[13]  P M Rautaharju,et al.  Identification of best electrocardiographic leads for diagnosing myocardial infarction by statistical analysis of body surface potential maps. , 1985, The American journal of cardiology.