Purpose
The purpose of this paper is to identify the impact of traditionally unmonitored energy sources and sinks on assessment of the as-built thermal performance of occupied homes. The analysis aims to demonstrate the potential scale of uncertainties introduced in a heat balance estimation of the heat transfer coefficient (HTC) when using in-use monitored data.
Design/methodology/approach
Energy flows for two UK homes – one a 1930s dwelling with high heat loss, the second a higher-performing 2014-built home – are predicted using the UK Government’s standard assessment procedure (SAP) and visualised using Sankey diagrams. Selected modelled energy flows are used as inputs in a quasi-steady state heat balance to calculate in-use HTCs as if from measured data sets gathered in occupied homes. The estimated in-use HTCs are compared against SAP-calculated values to illustrate the impact of including or omitting various heat sources and sinks.
Findings
The results demonstrate that for dwellings with low heat loss, the increased proportion of heating demand met by unmetered internal and solar gains informs a greater sensitivity of a heat balance estimation of the HTC to their omission. While simple quasi-steady state heat balance methods may be appropriate for dwellings with very high heat loss, alternative approaches are likely to be required for those with lower heat loss.
Originality/value
A need to understand the impacts of unmetered heat flows on the accuracy with which a building’s thermal performance may be inferred from in-use monitored data is identified: this paper illustrates the scale of these impacts for two homes at opposite ends of the energy performance scale.
[1]
Michael G. Pollitt,et al.
Building performance evaluation and certification in the UK: Is SAP fit for purpose?
,
2012
.
[2]
David Johnston,et al.
Whole House Heat Loss Test Method (Coheating)
,
2012
.
[3]
Dennis L. Loveday,et al.
Measuring the potential of zonal space heating controls to reduce energy use in UK homes: The case of un-furbished 1930s dwellings
,
2015
.
[4]
Geert Bauwens,et al.
In Situ Testing of a Building's Overall Heat Loss Coefficient - Embedding Quasi-stationary and Dynamic Tests in a Building Physical and Statistical Framework
,
2015
.
[5]
Matthew Brooke-Peat,et al.
Bridging the domestic building fabric performance gap
,
2016
.
[6]
Behzad Sodagar,et al.
The monitored performance of four social houses certified to the Code for Sustainable Homes Level 5
,
2016
.
[7]
Dennis L. Loveday,et al.
First evidence for the reliability of building co-heating tests
,
2018
.
[8]
Phillip Biddulph,et al.
A Bayesian Dynamic Method to Estimate the Thermophysical Properties of Building Elements in All Seasons, Orientations and with Reduced Error
,
2018
.
[9]
Rowena Hay,et al.
Post-occupancy evaluation in architecture: experiences and perspectives from UK practice
,
2018
.