Computer-aided Design/Computer-aided Manufacturing Protocol for Immediate Loading with Zirconia Implants

Yttria-tetragonal zirconia polycrystal (Y-TZP) is a material globally accepted for restorative and implant dentistry. The patient's increased demand for more biologic and esthetic materials has made metal-free treatment a routine in everyday dental practice. Zirconia implants have more recently appeared into our armamentarium and is today the treatment of choice for patients with metal allergies and other immune disorders that are related with metal sensitivities as well as esthetic demanding cases. The present case report describes the protocol used for immediate zirconia implants and immediate loading for the full-mouth rehabilitation using computer-aided design/computeraided manufacturing (cad/cam) technology.

[1]  J. Oliva,et al.  Zirconia implants and all-ceramic restorations for the esthetic replacement of the maxillary central incisors. , 2008, The European journal of esthetic dentistry : official journal of the European Academy of Esthetic Dentistry.

[2]  R. Kohal,et al.  A zirconia implant-crown system: a case report. , 2004, The International journal of periodontics & restorative dentistry.

[3]  Lars Sennerby,et al.  State of the art of oral implants. , 2008, Periodontology 2000.

[4]  J R Strub,et al.  Custom-made root analogue titanium implants placed into extraction sockets. An experimental study in monkeys. , 1997, Clinical oral implants research.

[5]  M. Kern,et al.  Osseointegration and clinical success of zirconia dental implants: a systematic review. , 2008, The International journal of prosthodontics.

[6]  C. de Putter,et al.  Front tooth replacement with Tübingen (Frialit) implants. , 1994, Journal of oral rehabilitation.

[7]  G. Heydecke,et al.  Optimal esthetics in single-tooth replacement with the Re-Implant system: a case report. , 1999, The International journal of prosthodontics.

[8]  G. Anneroth,et al.  Tissue integration of A12O3-ceramic dental implants (Frialit)--a case report. , 1990, Swedish dental journal.

[9]  Y. Sato,et al.  Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years' function in monkeys: a clinical and histologic study. , 1998, The Journal of prosthetic dentistry.

[10]  H. Hansson,et al.  Interface analysis of titanium and zirconium bone implants. , 1985, Biomaterials.

[11]  L. Sennerby,et al.  Bone tissue responses to surface-modified zirconia implants: A histomorphometric and removal torque study in the rabbit. , 2005, Clinical implant dentistry and related research.

[12]  Marina Andreiotelli,et al.  Are ceramic implants a viable alternative to titanium implants? A systematic literature review. , 2009, Clinical oral implants research.

[13]  J. Oliva,et al.  One-year follow-up of first consecutive 100 zirconia dental implants in humans: a comparison of 2 different rough surfaces. , 2007, The International journal of oral & maxillofacial implants.

[14]  J. Oliva,et al.  Ovoid zirconia implants: anatomic design for premolar replacement. , 2008, The International journal of periodontics & restorative dentistry.

[15]  R. Kohal,et al.  Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment. , 2004, Journal of periodontology.

[16]  K. Müller,et al.  LTT-MELISA is clinically relevant for detecting and monitoring metal sensitivity. , 2006, Neuro endocrinology letters.

[17]  Phophi Kamposiora,et al.  Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants. , 2002, The International journal of prosthodontics.

[18]  A. Wennerberg On surface roughness and implant incorporation , 1996 .

[19]  B. Kasemo,et al.  Biomaterial and implant surfaces: a surface science approach. , 1988, The International journal of oral & maxillofacial implants.

[20]  J. Oliva,et al.  Replacement of congenically missing maxillary permanent canine with a zirconium oxide dental implant and crown. A case report from an ongoing clinical study , 2008 .

[21]  S. Rb The osteotome technique: Part 3--Less invasive methods of elevating the sinus floor. , 1994 .

[22]  K. Valachová,et al.  Hypersensitivity to titanium: clinical and laboratory evidence. , 2006 .

[23]  A. Cittadini,et al.  Y-TZP ceramics for artificial joint replacements. , 1998, Biomaterials.

[24]  M. Rohrer,et al.  Osseointegration of Zirconia (Y-TZP) Dental Implants: A Histologic, Histomorphometric and Removal Torque Study in the Hip of Sheep , 2013 .

[25]  S. Eichhorn,et al.  Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. , 2007, Clinical oral implants research.

[26]  H. Tsuru,et al.  Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. , 1993, The Journal of prosthetic dentistry.

[27]  H Tsuru,et al.  Tissue compatibility and stability of a new zirconia ceramic in vivo. , 1992, The Journal of prosthetic dentistry.