Evaluation of Tizian overlays by means of a swept source optical coherence tomography system

The teeth affected by pathologic attrition can be restored by a minimally invasive approach, using Tizian overlays. In this study we prove the advantages of a fast swept source (SS) OCT system in the evaluation of Tizian overlays placed in an environment characterized by high occlusal forces. 12 maxillary first premolars were extracted and prepared for overlays. The Tizian overlays were subjected to 3000 alternating cycles of thermo-cycling (from -10°C to +50°C) and to mechanical occlusal overloads (at 800 N). A fast SS OCT system was used to evaluate the Tizian overlays before and after the mechanical and thermal straining. The SS (Axsun Technologies, Billerica, MA) has a central wavelength of 1060 nm, sweeping range of 106 nm (quoted at 10 dB) and a 100 kHz line rate. The depth resolution of the system, measured experimentally in air was 10 μm. The imaging system used for this study offers high spatial resolutions in both directions, transversal and longitudinal of around 10 μm, a high sensitivity, and it is also able to acquire entire tridimensional (3D)/volume reconstructions as fast as 2.5 s. Once the full dataset was acquired, rendered high resolutions en-face projections could be produced. Using them, the overlay (i.e., cement) abutment tooth interfaces were remarked both on B-scans/two-dimensional (2D) sections and in the 3D reconstructions. Using the system several open interfaces were possible to detect. The fast SS OCT system thus proves useful in the evaluation of zirconia reinforced composite overlays, placed in an environment characterized by high occlusal forces.

[1]  Adrian Bradu,et al.  Noninvasive Quantitative Evaluation of the Dentin Layer during Dental Procedures Using Optical Coherence Tomography , 2015, Comput. Math. Methods Medicine.

[2]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[3]  Hristina Pashova,et al.  Tooth wear: prevalence and associated factors in general practice patients. , 2010, Community dentistry and oral epidemiology.

[4]  G. Gelikonov,et al.  In vivo OCT imaging of hard and soft tissue of the oral cavity. , 1998, Optics express.

[5]  Virgil-Florin Duma,et al.  Experimental investigations of the scanning functions of galvanometer-based scanners with applications in OCT. , 2011, Applied optics.

[6]  Kye-Sung Lee,et al.  Three-dimensional imaging of normal skin and nonmelanoma skin cancer with cellular resolution using Gabor domain optical coherence microscopy , 2012, Journal of biomedical optics.

[7]  J. Rolland,et al.  Optimization of galvanometer scanning for optical coherence tomography. , 2015, Applied Optics.

[8]  J. Fujimoto,et al.  Three-dimensional endomicroscopy using optical coherence tomography , 2007 .

[9]  Adrian Bradu,et al.  Quality assessment of dental treatments using en-face optical coherence tomography. , 2008, Journal of biomedical optics.

[10]  Adrian Bradu,et al.  Quantitative evaluation of dental abfraction and attrition using a swept-source optical coherence tomography system , 2014, Journal of biomedical optics.

[11]  Adrian Bradu,et al.  Design and testing of prototype handheld scanning probes for optical coherence tomography , 2014, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  Adrian Bradu,et al.  Master-slave interferometry for parallel spectral domain interferometry sensing and versatile 3D optical coherence tomography. , 2013, Optics express.

[13]  J. Schuman,et al.  Optical coherence tomography. , 2000, Science.

[14]  Adrian Bradu,et al.  Assessment of the sealant/tooth interface using optical coherence tomography , 2015 .