Random gas mixtures for efficient gas sensor calibration

Abstract. Applications like air quality, fire detection and detection of explosives require selective and quantitative measurements in an ever-changing background of interfering gases. One main issue hindering the successful implementation of gas sensors in real-world applications is the lack of appropriate calibration procedures for advanced gas sensor systems. This article presents a calibration scheme for gas sensors based on statistically distributed gas profiles with unique randomized gas mixtures. This enables a more realistic gas sensor calibration including masking effects and other gas interactions which are not considered in classical sequential calibration. The calibration scheme is tested with two different metal oxide semiconductor sensors in temperature-cycled operation using indoor air quality as an example use case. The results are compared to a classical calibration strategy with sequentially increasing gas concentrations. While a model trained with data from the sequential calibration performs poorly on the more realistic mixtures, our randomized calibration achieves significantly better results for the prediction of both sequential and randomized measurements for, for example, acetone, benzene and hydrogen. Its statistical nature makes it robust against overfitting and well suited for machine learning algorithms. Our novel method is a promising approach for the successful transfer of gas sensor systems from the laboratory into the field. Due to the generic approach using concentration distributions the resulting performance tests are versatile for various applications.

[1]  M. Leidinger,et al.  Characterization and calibration of gas sensor systems at ppb level—a versatile test gas generation system , 2017 .

[2]  T. Sauerwald,et al.  Novel method for the detection of short trace gas pulses with metal oxide semiconductor gas sensors , 2018, Journal of Sensors and Sensor Systems.

[3]  D. Kohl,et al.  Detection of Fires by Gas Sensors , 2001 .

[4]  M. Bastuck Improving the Performance of Gas Sensor Systems with Advanced Data Evaluation, Operation, and Calibration Methods , 2019 .

[5]  T. Sauerwald,et al.  Comparison of ppb-level gas measurements with a metal-oxide semiconductor gas sensor in two independent laboratories , 2018, Sensors and Actuators B: Chemical.

[6]  Choongho Yu,et al.  Integration of metal oxide nanobelts with microsystems for nerve agent detection , 2005 .

[7]  J. Sluiter,et al.  Calibration Transfer Among Sensor Arrays Designed for Monitoring Volatile Organic Compounds in Indoor Air Quality , 2006, IEEE Sensors Journal.

[8]  Who Regional Office for Europe,et al.  WHO Guidelines for Indoor Air Quality: Selected Pollutants , 2011 .

[9]  Andreas Schütze,et al.  High performance solvent vapor identification with a two sensor array using temperature cycling and pattern classification , 2003 .

[10]  A. Gutierrez-Galvez,et al.  Signal and Data Processing for Machine Olfaction and Chemical Sensing: A Review , 2012, IEEE Sensors Journal.

[11]  Ramón Huerta,et al.  Dataset from chemical gas sensor array in turbulent wind tunnel , 2015, Data in brief.

[12]  M. Bastuck,et al.  DAV3E – a MATLAB toolbox for multivariate sensor data evaluation , 2018, Journal of Sensors and Sensor Systems.

[13]  B. Seifert Richtwerte für die Innenraumluft Die Beurteilung der Innenraumluftqualität mit Hilfe der Summe der flüchtigen organischen Verbindungen (TVOC-Wert) , 1999, Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz.

[14]  Tobias Baur,et al.  Highly Sensitive and Selective VOC Sensor Systems Based on Semiconductor Gas Sensors: How to? , 2017 .

[15]  Andreas Schütze,et al.  Optimierung des temperaturzyklischen Betriebs von Halbleitergassensoren , 2015 .

[16]  G. Oehlert A first course in design and analysis of experiments , 2000 .

[17]  J. Fonollosaa,et al.  Gas sensor array for reliable fire detection , 2018 .

[18]  Tobias Baur,et al.  Device for the detection of short trace gas pulses , 2018 .

[19]  N. Read,et al.  Investigation of normal flatus production in healthy volunteers. , 1991, Gut.

[20]  Jung-Sik Kim,et al.  Recent advances on H2 sensor technologies based on MOX and FET devices: A review , 2018, Sensors and Actuators B: Chemical.

[21]  Laurent Spinelle,et al.  Review of Portable and Low-Cost Sensors for the Ambient Air Monitoring of Benzene and Other Volatile Organic Compounds , 2017, Sensors.

[22]  Umweltbundesamt Beurteilung von Innenraumluftkontaminationen mittels Referenz- und Richtwerten , 2007, Bundesgesundheitsblatt - Gesundheitsforschung - Gesundheitsschutz.

[23]  M. Stone Cross‐Validatory Choice and Assessment of Statistical Predictions , 1976 .

[24]  Lei Zhang,et al.  Chaos based neural network optimization for concentration estimation of indoor air contaminants by an electronic nose , 2013 .

[25]  Jiaxing Zhang,et al.  Signal and data processing , 2015 .

[26]  Ingemar Lundström,et al.  Artificial neural networks and gas sensor arrays: quantification of individual components in a gas mixture , 1991 .

[27]  Laurent Francis,et al.  Assessment of air quality microsensors versus reference methods: The EuNetAir joint exercise , 2016 .

[28]  Célia Lourenço,et al.  Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications , 2014, Metabolites.

[29]  Jordi Fonollosa,et al.  Chemical gas sensor array dataset , 2015, Data in brief.

[30]  L. Spinelle,et al.  Highly sensitive benzene detection with metal oxide semiconductor gas sensors – an inter-laboratory comparison , 2018 .

[31]  T. Sauerwald,et al.  Dynamic operation of semiconductor sensors , 2020 .

[32]  M. Levitt Production and excretion of hydrogen gas in man. , 1969, The New England journal of medicine.

[33]  Michel Gerboles,et al.  Review of the Performance of Low-Cost Sensors for Air Quality Monitoring , 2019, Atmosphere.

[34]  Gregory P. Harmer,et al.  Detection of chemical warfare agents using nanostructured metal oxide sensors , 2005 .

[35]  Andreas Schütze,et al.  Gas mixing apparatus for automated gas sensor characterization , 2014 .

[36]  Tobias Baur,et al.  Facile Quantification and Identification Techniques for Reducing Gases over a Wide Concentration Range Using a MOS Sensor in Temperature-Cycled Operation , 2018, Sensors.

[37]  M. Fiegl,et al.  Noninvasive detection of lung cancer by analysis of exhaled breath , 2009, BMC Cancer.

[38]  Alena Bartonova,et al.  Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates? , 2017, Environment international.