Tibial bypass for limb salvage using polytetrafluoroethylene and a distal vein patch.

OBJECTIVE Tibial artery bypass for limb salvage may be required in patients without adequate autogenous vein. The interposition of venous tissue at the distal anastomosis has been advocated to improve the results of prosthetic grafts to tibial arteries. Having reported on technical feasibility and an early experience with polytetrafluoroethylene (PTFE) and a distal vein patch (DVP), we examine the results of this technique with 4-year follow-up. METHODS From July 1993 to July 1999, 514 tibial bypass grafts were performed, with 80 bypass grafts in 79 patients with PTFE/DVP as the conduit. Patient demographics included 39 men and 40 women (mean age, 67 years); 42 had diabetes mellitus (53%), 16 had renal failure (20%), and 48 had Eagle criteria for increased cardiac risk (60%). Indications for revascularization were rest pain in 39 (49%) and tissue loss in 41 (51%). Lack of adequate vein resulted from previous failed lower extremity bypass graft (47 [59%]), previous coronary bypass graft (21 [26%]), unsuitable vein (8 [10%]), and absent vein due to ligation and stripping (4 [5%]). Follow-up ranged from 1 to 48 months. Results are reported as primary patency or limb salvage +/- SE. RESULTS Bypass grafts originated from the common femoral artery (40 [50%]), the superficial femoral artery (6 [8%]), and the external iliac artery (34 [43%]). Recipient arteries included anterior tibial (17 [21%]), posterior tibial (28 [35%]), and peroneal (35 [44%]). Four-year primary patency and limb salvage rates were 62.89% +/- 10.6% and 79.21% +/- 8.45%, respectively. There was a 24% mortality rate during the follow-up period. Acute failure occurred in 7 grafts with 5 immediate amputations and 2 revisions. A total of 17 grafts failed during the follow-up period, leading to 11 amputations. CONCLUSION The DVP technique allows PTFE bypass grafts to tibial arteries with acceptable long-term patency and limb salvage.

[1]  S Glagov,et al.  Anastomotic intimal hyperplasia: mechanical injury or flow induced. , 1992, Journal of vascular surgery.

[2]  R. Rutherford,et al.  Recommended standards for reports dealing with lower extremity ischemia: revised version. , 1997, Journal of vascular surgery.

[3]  R. Depalma,et al.  Vein Cuff Interposition Prevents Juxta‐Anastomotic Neointimal Hyperplasia , 1988, Annals of surgery.

[4]  M. Kahn,et al.  Improved method to create the common ostium variant of the distal arteriovenous fistula for enhancing crural prosthetic graft patency. , 1996, Journal of vascular surgery.

[5]  J. Wolfe,et al.  New prosthetic venous collar anastomotic technique: Combining the best of other procedures , 1991, The British journal of surgery.

[6]  K. Calligaro,et al.  Use of arm and lesser saphenous vein compared with prosthetic grafts for infrapopliteal arterial bypass: are they worth the effort? , 1997, Journal of vascular surgery.

[7]  R. Leriche Advances in vascular surgery. , 1947, Lancet.

[8]  W. Yorkovich,et al.  Complementary distal arteriovenous fistula and deep vein interposition: a five-year experience with a new technique to improve infrapopliteal prosthetic bypass patency. , 1996, Journal of vascular surgery.

[9]  R. Hobson,et al.  Results of revascularization and amputation in severe lower extremity ischemia: a five-year clinical experience. , 1985, Journal of vascular surgery.

[10]  P. Kreienberg,et al.  Adjunctive techniques to improve patency of distal prosthetic bypass grafts: polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs. , 2000, Journal of vascular surgery.

[11]  J. Miller,et al.  Interposition vein cuff for anastomosis of prosthesis to small artery. , 1984, The Australian and New Zealand journal of surgery.

[12]  Robin J. Prescott,et al.  Randomized trial comparing infrainguinal polytetrafluoroethylene bypass grafting with and without vein interposition cuff at the distal anastomosis , 1997 .

[13]  K. Kent,et al.  What is the proper role of polytetrafluoroethylene grafts in infrainguinal reconstruction? , 1989, Journal of vascular surgery.

[14]  P. Bell,et al.  Are distal vascular procedures worthwhile? , 1985, The British journal of surgery.

[15]  J. S. Yao,et al.  Randomization of autogenous vein and polytetrafluorethylene grafts in femoral-distal reconstruction. , 1982, Surgery.

[16]  V. Bernhard,et al.  Six-year prospective multicenter randomized comparison of autologous saphenous vein and expanded polytetrafluoroethylene grafts in infrainguinal arterial reconstructions. , 1986, Journal of vascular surgery.

[17]  R. Depalma,et al.  The protective effect of vein cuffed anastomoses is not mechanical in origin. , 1995, Journal of vascular surgery.

[18]  P L Harris,et al.  Interposition vein cuff anastomosis alters wall shear stress distribution in the recipient artery. , 2000, Journal of vascular surgery.

[19]  C. Attinger,et al.  Prosthetic bypass with a distal vein patch for limb salvage. , 1997, American journal of surgery.

[20]  P. Pappas,et al.  Patency and Limb Salvage for Polytetrafluoroethylene Bypasses with Vein Interposition Cuffs , 1999, Annals of vascular surgery.

[21]  A. Loh,et al.  Improved technique for polytetrafluoroethylene bypass grafting: Long‐term results using anastomotic vein patches , 1992, The British journal of surgery.

[22]  F. Logerfo,et al.  Results of a policy with arm veins used as the first alternative to an unavailable ipsilateral greater saphenous vein for infrainguinal bypass. , 1996, Journal of vascular surgery.