Validity and Reliability of an Inertial Device for Measuring Dynamic Weight-Bearing Ankle Dorsiflexion

A decrease in ankle dorsiflexion causes changes in biomechanics, and different instruments have been used for ankle dorsiflexion testing under static conditions. Consequently, the industry of inertial sensors has developed easy-to-use devices, which measure dynamic ankle dorsiflexion and provide additional parameters such as velocity, acceleration, or movement deviation. Therefore, the aims of this study were to analyze the concurrent validity and test-retest reliability of an inertial device for measuring dynamic weight-bearing ankle dorsiflexion. Sixteen participants were tested using an inertial device (WIMU) and a digital inclinometer. Ankle dorsiflexion from left and right ankle repetitions was used for validity analysis, whereas test-retest reliability was analyzed by comparing measurements from the first and second days. The standard error of the measurement (SEM) between the instruments was very low for both ankle measurements (SEM < 0.6°). No significant differences between instruments were found for the left ankle measurement (p > 0.05) even though a significant systematic bias (~1.77°) was found for the right ankle (d = 0.79). R2 was very close to 1 in the left and right ankles (R2 = 0.85–0.89) as well as the intraclass correlation coefficient (ICC > 0.95). Test-retest reliability analysis showed that systematic bias was below 1° for both instruments, even though a systematic bias (~1.50°) with small effect size was found in the right ankle (d = 0.49) with WIMU. The ICC was very close to 1 and the coefficient of variation (CV) was lower than 4% in both instruments. Thus, WIMU is a valid and reliable inertial device for measuring dynamic weight-bearing ankle dorsiflexion.

[1]  Alejandro Bastida Castillo,et al.  Accuracy, intra- and inter-unit reliability, and comparison between GPS and UWB-based position-tracking systems used for time–motion analyses in soccer , 2018, European journal of sport science.

[2]  Natalia Romero-Franco,et al.  Concurrent validity and reliability of an iPhone app for the measurement of ankle dorsiflexion and inter-limb asymmetries , 2019, Journal of sports sciences.

[3]  J. Muyor Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility , 2017, International Journal of Sports Medicine.

[4]  T. Enoki,et al.  Inter-rater reliability and validity of angle measurements using smartphone applications for weight-bearing ankle dorsiflexion range of motion measurements. , 2018, Physical therapy in sport : official journal of the Association of Chartered Physiotherapists in Sports Medicine.

[5]  P. Lachenbruch Statistical Power Analysis for the Behavioral Sciences (2nd ed.) , 1989 .

[6]  John Ludbrook,et al.  Statistical Techniques For Comparing Measurers And Methods Of Measurement: A Critical Review , 2002, Clinical and experimental pharmacology & physiology.

[7]  Nachiappan Chockalingam,et al.  Validity and reliability of a new ankle dorsiflexion measurement device , 2013, Prosthetics and orthotics international.

[8]  L Dubs [Risk factors for plantar fasciitis]. , 2003, Praxis.

[9]  K. Landorf,et al.  A weightbearing technique for the measurement of ankle joint dorsiflexion with the knee extended is reliable. , 2009, Journal of science and medicine in sport.

[10]  Bruce Carse,et al.  Affordable clinical gait analysis: an assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system. , 2013, Physiotherapy.

[11]  Peter Pidcoe,et al.  Risk Factors for Plantar Fasciitis: A Matched Case-Control Study , 2003, The Journal of bone and joint surgery. American volume.

[12]  Edgar Erdfelder,et al.  G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences , 2007, Behavior research methods.

[13]  Carlos Balsalobre-Fernández,et al.  Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise , 2019, Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology.

[14]  J. Hoch,et al.  Reliability and minimal detectable change of the weight-bearing lunge test: A systematic review. , 2015, Manual therapy.

[15]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[16]  Alexandre Campeau-Lecours,et al.  Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review , 2019, Sensors.

[17]  Daniel Tik-Pui Fong,et al.  The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review , 2010, Sensors.

[18]  S. Bronner,et al.  Reliability and validity of a new ankle electrogoniometer , 2010, Journal of medical engineering & technology.

[19]  Brian Smith,et al.  Closing the Wearable Gap—Part III: Use of Stretch Sensors in Detecting Ankle Joint Kinematics During Unexpected and Expected Slip and Trip Perturbations , 2019, Electronics.

[20]  J. Pino-Ortega,et al.  Validity and reliability of an inertial device (WIMU PROTM) to quantify physical activity level through steps measurement. , 2019, The Journal of sports medicine and physical fitness.

[21]  H. Yack,et al.  A new device for assessing ankle dorsiflexion motion: reliability and validity. , 2011, The Journal of orthopaedic and sports physical therapy.

[22]  John Nelson,et al.  Multi-Sensor Fusion for Enhanced Contextual Awareness of Everyday Activities with Ubiquitous Devices , 2014, Sensors.

[23]  Subhas Chandra Mukhopadhyay,et al.  Wearable Sensors for Human Activity Monitoring: A Review , 2015, IEEE Sensors Journal.

[24]  T. Grindstaff,et al.  Reliability of three measures of ankle dorsiflexion range of motion. , 2012, International journal of sports physical therapy.

[25]  A R Mason-Mackay,et al.  The effect of reduced ankle dorsiflexion on lower extremity mechanics during landing: A systematic review. , 2017, Journal of science and medicine in sport.

[26]  P. Danielson,et al.  Low Range of Ankle Dorsiflexion Predisposes for Patellar Tendinopathy in Junior Elite Basketball Players , 2011, The American journal of sports medicine.

[27]  Peter Kent,et al.  Reduced ankle dorsiflexion range may increase the risk of patellar tendon injury among volleyball players. , 2006, Journal of science and medicine in sport.

[28]  Zoran Šarčević Limited ankle dorsiflexion: a predisposing factor to Morbus Osgood Schlatter? , 2008, Knee Surgery, Sports Traumatology, Arthroscopy.

[29]  Shaw Bronner,et al.  Comparison of Functional Ankle Motion Measures in Modern Dancers , 2012, Journal of dance medicine & science : official publication of the International Association for Dance Medicine & Science.

[30]  Jacob Cohen Statistical Power Analysis for the Behavioral Sciences , 1969, The SAGE Encyclopedia of Research Design.

[31]  J. Barr,et al.  Ankle dorsiflexion range of motion influences dynamic balance in individuals with chronic ankle instability. , 2013, International journal of sports physical therapy.

[32]  Javier García-Rubio,et al.  Static and dynamic reliability of WIMU PRO™ accelerometers according to anatomical placement , 2018, Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology.

[33]  Nhan Nguyen,et al.  Assessment of Shoulder Range of Motion Using a Wireless Inertial Motion Capture Device—A Validation Study , 2019, Sensors.

[34]  Carlos Romero Morales,et al.  The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults , 2017, PeerJ.

[35]  Roman Kamnik,et al.  An inertial and magnetic sensor based technique for joint angle measurement. , 2007, Journal of biomechanics.

[36]  James E Ball,et al.  Closing the Wearable Gap: Mobile Systems for Kinematic Signal Monitoring of the Foot and Ankle , 2018, Electronics.

[37]  John H Hollman,et al.  Measurement of ankle dorsiflexion: a comparison of active and passive techniques in multiple positions. , 2011, Journal of sport rehabilitation.

[38]  Ernesto De la Cruz Sánchez,et al.  Accuracy, intra- and inter-unit reliability, and comparison between GPS and UWB-based position-tracking systems used for time-motion analyses in soccer. , 2018 .

[39]  P. J. Marín,et al.  The validity and reliability of a new instrumented device for measuring ankle dorsiflexion range of motion. , 2015, International journal of sports physical therapy.

[40]  Carlos Balsalobre-Fernández,et al.  Use of Mobile Applications to Collect Data in Sport, Health, and Exercise Science: A Narrative Review. , 2017, Journal of strength and conditioning research.

[41]  J. Pino-Ortega,et al.  Validity and reliability of the WIMU inertial device for the assessment of the vertical jump , 2018, PeerJ.

[42]  Paulino Granero-Gil,et al.  Reliability and validity of a new accelerometer (Wimu®) system for measuring velocity during resistance exercises , 2018 .

[43]  M. Fredericson,et al.  Iliotibial Band Syndrome in Runners , 2005, Sports medicine.

[44]  E. Rasmussen-Barr,et al.  Anterior cruciate ligament injury and ankle dorsiflexion , 2015, Knee Surgery, Sports Traumatology, Arthroscopy.

[45]  Roger P. Woods,et al.  Ankle dorsiflexion as an fMRI paradigm to assay motor control for walking during rehabilitation , 2004, NeuroImage.

[46]  Darin A Padua,et al.  Ankle-dorsiflexion range of motion and landing biomechanics. , 2011, Journal of athletic training.

[47]  H. Zuiderbaan,et al.  Validity and Reliability of the Achillometer(®): An Ankle Dorsiflexion Measurement Device. , 2016, The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons.