Optimized PID control of propofol and remifentanil coadministration for general anesthesia

Abstract A closed-loop control system for the control of the depth of hypnosis in anesthesia by using propofol-remifentanil coadministration and the Bispectral Index as feedback signal is proposed. A PID controller is employed together with a fixed ratio between propofol and remifentanil infusions. The ratio allows the anesthesiologist to control the opioid-hypnotic balance during surgery. Optimal tuning rules for the proposed controller are obtained off-line by using the particle swarm optimization method and by considering a given dataset of patients and a wide range of infusion ratios that covers a rich set of scenarios that might occur in clinical practice. Finally, a gain scheduling strategy guarantees the optimality of the performance both for the induction and the maintenance phase. A Monte Carlo approach is used to evaluate the robustness of the method with respect to intra- and inter-patient variability.

[1]  Clara M. Ionescu,et al.  Advanced Model-Based Control Studies for the Induction and Maintenance of Intravenous Anaesthesia , 2015, IEEE Transactions on Biomedical Engineering.

[2]  C. Rosow,et al.  Bispectral index monitoring , 2001 .

[3]  Alexander Medvedev,et al.  Synthetic Patient Database of Drug Effect in General Anesthesia for Evaluation of Estimation and Control Algorithms , 2018 .

[4]  Kristian Soltesz,et al.  Design and Clinical Evaluation of Robust PID Control of Propofol Anesthesia in Children , 2014, IEEE Transactions on Control Systems Technology.

[5]  Antonio Visioli,et al.  Event-Based control of depth of hypnosis in anesthesia , 2017, Comput. Methods Programs Biomed..

[6]  Antonio Visioli,et al.  Practical PID Control , 2006 .

[7]  Guy Albert Dumont,et al.  Introduction to Automated Drug Delivery in Clinical Anesthesia , 2005, Eur. J. Control.

[8]  W. Haddad,et al.  Drug dosing control in clinical pharmacology , 2005, IEEE Control Systems.

[9]  Julio E. Normey-Rico,et al.  Robust Predictive Control Strategy Applied for Propofol Dosing Using BIS as a Controlled Variable During Anesthesia , 2008, IEEE Transactions on Biomedical Engineering.

[10]  G. Kenny,et al.  Propofol sparing effect of remifentanil using closed-loop anaesthesia. , 2003, British journal of anaesthesia.

[11]  Chuang Liu,et al.  Design of Type-1 and Interval Type-2 Fuzzy PID Control for Anesthesia Using Genetic Algorithms , 2014 .

[12]  A. Visioli,et al.  On the Identification of the Propofol PK/PD Model Using BIS Measurements , 2017 .

[13]  Bernhard P. Lampe,et al.  Design and implementation of a control system reflecting the level of analgesia during general anesthesia , 2013, Biomedizinische Technik. Biomedical engineering.

[14]  T. Bouillon,et al.  Non–steady State Analysis of the Pharmacokinetic Interaction between Propofol and Remifentanil , 2002, Anesthesiology.

[15]  E Olofsen,et al.  Propofol Anesthesia and Rational Opioid Selection: Determination of Optimal EC50‐EC95 Propofol‐Opioid Concentrations that Assure Adequate Anesthesia and a Rapid Return of Consciousness , 1997, Anesthesiology.

[16]  Gade Pandu Rangaiah,et al.  Advanced Control Strategies for the Regulation of Hypnosis with Propofol , 2009 .

[17]  Riccardo Poli,et al.  Particle swarm optimization , 1995, Swarm Intelligence.

[18]  Hugo Vereecke,et al.  Spectral Entropy as an Electroencephalographic Measure of Anesthetic Drug Effect: A Comparison with Bispectral Index and Processed Midlatency Auditory Evoked Response , 2004, Anesthesiology.

[19]  Guy A. Dumont,et al.  Closed-Loop Control of Anesthesia - a Review , 2012 .

[20]  Robin De Keyser,et al.  Evaluation of a Propofol and Remifentanil interaction model for predictive control of anesthesia induction , 2011, IEEE Conference on Decision and Control and European Control Conference.

[21]  A. Absalom,et al.  Closed-loop control of propofol anaesthesia using bispectral index: performance assessment in patients receiving computer-controlled propofol and manually controlled remifentanil infusions for minor surgery. , 2003, British journal of anaesthesia.

[22]  A. Dassonneville,et al.  PhysioDoloris: a monitoring device for Analgesia / Nociception balance evaluation using Heart Rate Variability analysis , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[23]  M. Janda,et al.  Clinical evaluation of a simultaneous closed‐loop anaesthesia control system for depth of anaesthesia and neuromuscular blockade * , 2011, Anaesthesia.

[24]  Thomas M Hemmerling,et al.  The Feasibility of a Completely Automated Total IV Anesthesia Drug Delivery System for Cardiac Surgery , 2016, Anesthesia and analgesia.

[25]  B. Jamerson,et al.  Remifentanil Compared with Alfentanil for Ambulatory Surgery Using Total Intravenous Anesthesia , 1997, Anesthesia and analgesia.

[26]  K. Leslie,et al.  Low Bispectral Index Values and Death: The Unresolved Causality Dilemma , 2011, Anesthesia and analgesia.

[27]  Michel M R F Struys,et al.  Performance Evaluation of Two Published Closed-loop Control Systems Using Bispectral Index Monitoring: A Simulation Study , 2004, Anesthesiology.

[28]  Tore Hägglund,et al.  Individualized closed-loop control of propofol anesthesia: A preliminary study , 2013, Biomed. Signal Process. Control..

[29]  Morgan Le Guen,et al.  Feasibility of Closed-loop Titration of Propofol and Remifentanil Guided by the Spectral M-Entropy Monitor , 2012, Anesthesiology.

[30]  Clara M. Ionescu,et al.  Optimized PID control of depth of hypnosis in anesthesia , 2017, Comput. Methods Programs Biomed..

[31]  Guy A. Dumont,et al.  Robust MISO Control of Propofol-Remifentanil Anesthesia Guided by the NeuroSENSE Monitor , 2018, IEEE Transactions on Control Systems Technology.

[32]  Thomas W. Schnider,et al.  Influence of age and gender on the pharmacokinetics and pharmacodynamics of remifentanil. I. Model development , 1997 .

[33]  G. Xie,et al.  A Response Surface Analysis of Propofol–Remifentanil Pharmacodynamic Interaction in Volunteers , 2004, Anesthesiology.

[34]  Teresa Mendonça,et al.  Controlling the depth of anesthesia by a novel positive control strategy , 2014, Comput. Methods Programs Biomed..

[35]  Charles E. Brown Applied Multivariate Statistics in Geohydrology and Related Sciences , 1998 .

[36]  S L Shafer,et al.  The influence of age on propofol pharmacodynamics. , 1999, Anesthesiology.

[37]  G D Puri,et al.  Closed-Loop Anaesthesia Delivery System (CLADSTM) using Bispectral Index: A Performance Assessment Study , 2007, Anaesthesia and intensive care.

[38]  Laurent Beydon,et al.  Closed-Loop Coadministration of Propofol and Remifentanil Guided by Bispectral Index: A Randomized Multicenter Study , 2011, Anesthesia and analgesia.

[39]  Efstratios N. Pistikopoulos,et al.  Explicit hybrid model predictive control strategies for intravenous anaesthesia , 2017, Comput. Chem. Eng..

[40]  M. Struys,et al.  Comparison of Closed-loop Controlled Administration of Propofol Using Bispectral Index as the Controlled Variable versus “Standard Practice” Controlled Administration , 2001, Anesthesiology.

[41]  Fredrik Granath,et al.  Mortality Within 2 Years After Surgery in Relation to Low Intraoperative Bispectral Index Values and Preexisting Malignant Disease , 2009, Anesthesia and analgesia.

[42]  Tore Hägglund,et al.  Simulated mid-ranging control of propofol and remifentanil using EEG-measured hypnotic depth of anesthesia , 2012, 2012 IEEE 51st IEEE Conference on Decision and Control (CDC).

[43]  Antonio Visioli,et al.  Inversion-based propofol dosing for intravenous induction of hypnosis , 2016, Commun. Nonlinear Sci. Numer. Simul..

[44]  Spencer S. Liu Effects of Bispectral Index Monitoring on Ambulatory Anesthesia: A Meta-analysis of Randomized Controlled Trials and a Cost Analysis , 2004, Anesthesiology.

[45]  Guy A. Dumont,et al.  Robust control of depth of anesthesia , 2008 .

[46]  Galit Zuckerman,et al.  Monitoring the nociception level: a multi-parameter approach , 2013, Journal of Clinical Monitoring and Computing.

[47]  S. Shafer,et al.  The Influence of Method of Administration and Covariates on the Pharmacokinetics of Propofol in Adult Volunteers , 1998, Anesthesiology.

[48]  Efstratios N. Pistikopoulos,et al.  Model predictive control of anesthesia under uncertainty , 2014, Comput. Chem. Eng..

[49]  Tony Gin,et al.  BIS-guided Anesthesia Decreases Postoperative Delirium and Cognitive Decline , 2013, Journal of neurosurgical anesthesiology.

[50]  Luc Barvais,et al.  Titration of Propofol for Anesthetic Induction and Maintenance Guided by the Bispectral Index: Closed-loop versus Manual Control: A Prospective, Randomized, Multicenter Study , 2006, Anesthesiology.