Design of dynamic voltage restorer and active power filter for wind power systems subject to unbalanced and harmonic distorted grid

Nowadays unbalanced voltage and harmonic distortion are in the majority of the power quality problems in wind energy conversion systems (WECS). To alleviate the impact registered by unbalanced and harmonic distortion, a new circuit topology comprising a dynamic voltage restorer (DVR) and an active power filter (APF) is presented. A frequency shifting technique based on coordinate transformation is employed to unify the positive and negative sequence harmonics into a resonant current controller. To improve the accuracy for harmonic detection, a second-order generalized integrator (SOGI), characterized with large bandwidth at specific frequency, is capable of separating harmonics from feeder current. The fundamental and harmonic current controllers can be individually realized by the resonant current controller and combined to form voltage command for a voltage-sourced inverter (VSI) based on superposition theorem. Not only the computing time but also the harmonic currents in the feeder can be effectively reduced along with the proposed approach. To share the dc-circuit with the DVR, the APF and DVR are in back-to-back connection in favor of unbalanced and harmonic compensation for specific grid bus. A 3kW squirrel cage induction generator (SCIG) driven by a permanent synchronous motor (PMSM) is performed for wind-turbine generator emulation. The experimental results validate that the grid-tied SCIG power quality can be refined when grid bus is subjected to unbalanced and harmonic distortion.

[1]  Yukihiko Sato,et al.  A new control strategy for voltage type PWM rectifiers to realise zero steady-state control error in input current , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[2]  Igor Papic,et al.  A Proportional-Resonant Current Controller for Selective Harmonic Compensation in a Hybrid Active Power Filter , 2014, IEEE Transactions on Power Delivery.

[3]  Woei-Luen Chen,et al.  Dynamic symmetrical components analysis and compensation for unbalanced distribution systems , 2015, 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia).

[4]  Frede Blaabjerg,et al.  Proportionalresonant controllers and filters for gridconnected voltagesource converters , 2006 .

[5]  Frede Blaabjerg,et al.  A Robust Control Scheme for Medium-Voltage-Level DVR Implementation , 2007, IEEE Transactions on Industrial Electronics.

[6]  C. Sundarabalan,et al.  Real coded GA optimized fuzzy logic controlled PEMFC based Dynamic Voltage Restorer for reparation of voltage disturbances in distribution system , 2017 .

[7]  C. K. Sundarabalan,et al.  PEM fuel cell supported distribution static compensator for power quality enhancement in three-phase four-wire distribution system , 2014 .

[8]  P. Sathishbabu Unified Power Quality Conditioner for Enhancement of Power Quality and Hybrid Power Generation Injection to Grid , 2012 .

[9]  Woei-Luen Chen,et al.  One-Dimensional Optimization for Proportional–Resonant Controller Design Against the Change in Source Impedance and Solar Irradiation in PV Systems , 2014, IEEE Transactions on Industrial Electronics.

[10]  Shoji Fukuda,et al.  A novel current-tracking method for active filters based on a sinusoidal internal model [for PWM inv , 2001 .

[11]  P. Sathishbabu,et al.  Mitigation of Power Quality Issues using Distributed Generation based Custom Power Device , 2012 .

[12]  F. Blaabjerg,et al.  Optimized Control Strategy for a Medium-Voltage DVR—Theoretical Investigations and Experimental Results , 2008, IEEE Transactions on Power Electronics.

[13]  C. K. Sundarabalan,et al.  Mitigation of Power Quality Issues in Three-Phase Four-Wire Distribution System Employing Four-Leg DSTATCOM , 2015 .

[14]  Frede Blaabjerg,et al.  Frequency Response Analysis of Current Controllers for Selective Harmonic Compensation in Active Power Filters , 2009, IEEE Transactions on Industrial Electronics.

[15]  S. Fukuda,et al.  A novel current tracking method for active filters based on a sinusoidal internal model , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[16]  S. R. Naidu,et al.  Dynamic voltage restorer based on a four-leg voltage source converter , 2009 .

[17]  G. Sivaranjani,et al.  EMOTION RECOGNITION FROM SPEECH WITH GAUSSIAN MIXTURE MODELS AND VIA BOOSTED GMM , 2018 .

[18]  D. G. Holmes,et al.  Frequency domain analysis of three phase linear current regulators , 1999, Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370).

[19]  C. K. Sundarabalan,et al.  Performance Investigation of Fuzzy Logic Controlled MPPT for Energy Efficient Solar PV Systems , 2015 .

[20]  Frede Blaabjerg,et al.  Proportional-resonant controllers and filters for grid-connected voltage-source converters , 2006 .

[21]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[22]  Divyaprakash Sharma,et al.  Performance of induction motor at low and high speed using model predictive control method , 2016 .

[23]  C. K. Sundarabalan,et al.  Power Quality Enhancement in Power Distribution system using Artificial intelligence based Dynamic Voltage Restorer , 2013 .

[24]  C. K. Sundarabalan,et al.  Compensation of voltage disturbances using PEMFC supported Dynamic Voltage Restorer , 2015 .

[25]  Heng Nian,et al.  An improved control strategy for DFIG system and dynamic voltage restorer under grid voltage dip , 2012, 2012 IEEE International Symposium on Industrial Electronics.

[26]  F. Blaabjerg,et al.  Investigation and Improvement of Transient Response of DVR at Medium Voltage Level , 2007, IEEE Transactions on Industry Applications.

[27]  F. Blaabjerg,et al.  High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters , 2007, IEEE Transactions on Power Electronics.

[28]  P. Sathishbabu,et al.  Dynamic Control of Power Distribution System and Hybrid Power Generation Injection to Grid using UPQC , 2012 .

[29]  Ryota Imamura,et al.  Application of a sinusoidal internal model to current control of three-phase utility-interface converters , 2005, IEEE Transactions on Industrial Electronics.

[30]  Gurpreet Singh Lehal,et al.  A Survey of Text Mining Techniques and Applications , 2009 .