The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor

[Purpose] The purpose of this study is to find the best body spots on the chest and abdomen wall to obtain the correlated indicators to the vital capacity. [Subjects and Methods] Thirty healthy male staff of the center served as the participants were advised to conduct a breathing movement using spirometer and a wearable strain sensor (WSS) respectively, which was the measured at four spots on chest and abdomen wall from maximal end of inspiration to maximal end of expiration. The Pearson’s correlation analysis was conducted to find the correlation of the data obtained respectively by the WSS and spirometer. [Results] The correlation of the mobility data at the four body spots to the vital capacity data were calculated for each level by means of Pearson’s correlation coefficient, which showed that the values at each body spot were positive significant correlations and the highest value was at the 10th rib. [Conclusion] There was a correlation between the mobility data of the chest and abdomen obtained by the WSS and the vital capacity data obtained by the spirometer, for which, the 10th rib is the best body spot to detect the positive significant correlation.

[1]  John F. Nunn,et al.  Nunn's Applied Respiratory Physiology , 1993 .

[2]  P. Casán,et al.  Effects of 8-week, interval-based inspiratory muscle training and breathing retraining in patients with generalized myasthenia gravis. , 2005, Chest.

[3]  B. Walder,et al.  Prophylactic respiratory physiotherapy after cardiac surgery: systematic review , 2003, BMJ : British Medical Journal.

[4]  C. Malaguti,et al.  Reliability of chest wall mobility and its correlation with pulmonary function in patients with chronic obstructive pulmonary disease. , 2009, Respiratory care.

[5]  Sujie Chen,et al.  Highly Sensitive and Transparent Strain Sensor Based on Thin Elastomer Film , 2016, IEEE Electron Device Letters.

[6]  Giancarlo Ferrigno,et al.  Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing , 1985, IEEE Transactions on Biomedical Engineering.

[7]  Pierre Baconnier,et al.  Respiratory inductive plethysmography to assess respiratory variability and complexity in humans , 2007, Respiratory Physiology & Neurobiology.

[8]  F. Kakizaki,et al.  Effects of Two Sitting Positions on Chest Volume , 2015 .

[9]  J E Cotes,et al.  Lung volumes and forced ventilatory flows , 1993, European Respiratory Journal.

[10]  D. Harris,et al.  The physiology of respiration , 1994, Perfusion.

[11]  Jessica Daecher Measurement In Physical Education , 2016 .

[12]  V. Wright,et al.  An objective clinical study of chest expansion. , 1972, Annals of the rheumatic diseases.

[13]  M. Olsén,et al.  Reliability of the Respiratory Movement Measuring Instrument, RMMI , 2010, Clinical physiology and functional imaging.