Retrospective Evaluation of Corneal Foreign Bodies with Anterior Segment Optical Coherence Tomography

Objectives: To assess the anterior segment optical coherence tomography (AS-OCT) findings of various types of corneal foreign bodies. Materials and Methods: The medical records of patients with corneal foreign body were retrospectively analyzed. Patients who underwent anterior segment photography and Spectralis AS-OCT (Heidelberg Engineering GmbH, Germany) imaging were included. Results: The AS-OCT findings of 22 eyes of 20 patients with corneal foreign body were reviewed. The mean age was 34.9±14.98 years (range, 15-71) with a female/male ratio of 4/16. The mean best corrected visual acuity at presentation was 0±0 LogMAR (range, 0-0). There were 18 metallic, 3 organic (chestnut burr), and 1 chemical clay foreign bodies. The metal materials demonstrated hyperreflectivity with a mirror effect. Chemical clay, which is an opaque material, had a hyperreflective appearance. Chestnut burr is an organic foreign body with a feather-like pattern and was not detected with AS-OCT. Conclusion: AS-OCT is a valuable non-invasive tool to define the characteristics of foreign bodies, as well as decide the proper treatment method and monitor patients with corneal foreign bodies.

[1]  D. Goldenberg,et al.  Characterization of deeply embedded corneal foreign bodies with anterior segment optical coherence tomography , 2019, Graefe's Archive for Clinical and Experimental Ophthalmology.

[2]  Raúl Martín,et al.  Anterior segment optical coherence tomography for evaluation of cornea and ocular surface , 2018, Indian journal of ophthalmology.

[3]  A. Celebi,et al.  The role of anterior segment optical coherence tomography in the management of an intra-corneal foreign body , 2016, SpringerPlus.

[4]  R. J. House,et al.  Corneal Abrasions and Corneal Foreign Bodies. , 2015, Primary care.

[5]  S. Arora,et al.  Management of intrastromal glass foreign body based on anterior segment optical coherence tomography and Pentacam analysis , 2015, International Ophthalmology.

[6]  Irfan Uzun,et al.  Yüzeyel korneal yabancı cisimlerde tedaviye kadar geçen süre ile ilişkili faktörlerin değerlendirilmesi , 2013 .

[7]  B. Ghosh,et al.  Anterior segment optical coherence tomography in intracorneal foreign body , 2012, Oman journal of ophthalmology.

[8]  N. Maeda Optical Coherence Tomography for Corneal Diseases , 2010, Eye & contact lens.

[9]  D. Covert,et al.  Well-Tolerated Intracorneal Wood Foreign Body of 40-Year Duration , 2009, Cornea.

[10]  Cynthia Owsley,et al.  Incidence of emergency department-treated eye injury in the United States. , 2005, Archives of ophthalmology.

[11]  R. P. Danis,et al.  The epidemiology of serious eye injuries from the United States Eye Injury Registry , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[12]  C. Margo,et al.  Patterns of emergency department visits for disorders of the eye and ocular adnexa. , 1998, Archives of ophthalmology.

[13]  D. Henderson Ocular trauma: one in the eye for safety glasses. , 1991, Archives of emergency medicine.

[14]  P L Hibberd,et al.  The spectrum and burden of ocular injury. , 1988, Ophthalmology.

[15]  T A Karlson,et al.  The incidence of acute hospital-treated eye injuries. , 1986, Archives of ophthalmology.

[16]  L. Pizzarello Ocular trauma: time for action. , 1998, Ophthalmic epidemiology.