Walking speed estimation using a shank-mounted inertial measurement unit.

We studied the feasibility of estimating walking speed using a shank-mounted inertial measurement unit. Our approach took advantage of the inverted pendulum-like behavior of the stance leg during walking to identify a new method for dividing up walking into individual stride cycles and estimating the initial conditions for the direct integration of the accelerometer and gyroscope signals. To test its accuracy, we compared speed estimates to known values during walking overground and on a treadmill. The speed estimation method worked well across treadmill speeds and slopes yielding a root mean square speed estimation error of only 7%. It also worked well during overground walking with a 4% error in the estimated travel distance. This accuracy is comparable to that achieved from foot-mounted sensors, providing an alternative in sensor positioning for walking speed estimation. Shank mounted sensors may be of great benefit for estimating speed in walking with abnormal foot motion and for the embedded control of knee-mounted devices such as prostheses and energy harvesters.

[1]  J. Judge,et al.  Exercise to improve gait velocity in older persons. , 1993, Archives of physical medicine and rehabilitation.

[2]  G. Cavagna,et al.  Mechanical work in terrestrial locomotion: two basic mechanisms for minimizing energy expenditure. , 1977, The American journal of physiology.

[3]  C. Richards,et al.  Task-specific physical therapy for optimization of gait recovery in acute stroke patients. , 1993, Archives of physical medicine and rehabilitation.

[4]  J A Hoffer,et al.  Biomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort , 2008, Science.

[5]  R. V. van Lummel,et al.  The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes. , 2006, Journal of biomechanics.

[6]  A. Hof,et al.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. , 2003, Gait & posture.

[7]  Lihua Huang,et al.  Hybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX) , 2006, Int. J. Robotics Res..

[8]  B. E. Maki,et al.  Gait Changes in Older Adults: Predictors of Falls or Indicators of Fear? , 1997, Journal of the American Geriatrics Society.

[9]  Hugh Herr,et al.  User-adaptive control of a magnetorheological prosthetic knee , 2003, Ind. Robot.

[10]  T P Andriacchi,et al.  Walking speed as a basis for normal and abnormal gait measurements. , 1977, Journal of biomechanics.

[11]  Shyamal Patel,et al.  Design, Control and Human Testing of an Active Knee Rehabilitation Orthotic Device , 2007, Proceedings 2007 IEEE International Conference on Robotics and Automation.

[12]  K. Aminian,et al.  Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty , 1999, Medical & Biological Engineering & Computing.

[13]  P.H. Veltink,et al.  Inclination measurement of human movement using a 3-D accelerometer with autocalibration , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  Kamiar Aminian,et al.  Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. , 2002, Journal of biomechanics.

[15]  R. Kram,et al.  Mechanical energy fluctuations during hill walking: the effects of slope on inverted pendulum exchange , 2006, Journal of Experimental Biology.

[16]  S. Miyazaki,et al.  Long-term unrestrained measurement of stride length and walking velocity utilizing a piezoelectric gyroscope , 1997, IEEE Transactions on Biomedical Engineering.

[17]  Angelo M. Sabatini,et al.  Assessment of walking features from foot inertial sensing , 2005, IEEE Transactions on Biomedical Engineering.

[18]  M. Goldstein,et al.  Management of cerebral palsy: equinus gait. , 2001, Developmental medicine and child neurology.

[19]  Jorunn L Helbostad,et al.  Estimation of gait cycle characteristics by trunk accelerometry. , 2004, Journal of biomechanics.

[20]  J. Allum,et al.  Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals. , 2006, Gait & posture.

[21]  M.R. Popovic,et al.  A reliable gait phase detection system , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.