Moving magnetoencephalography towards real-world applications with a wearable system

Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.

[1]  Catharina Zich,et al.  Mobile EEG and its potential to promote the theory and application of imagery-based motor rehabilitation. , 2014, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[2]  F. L. D. Silva,et al.  Event-related EEG/MEG synchronization and desynchronization: basic principles , 1999, Clinical Neurophysiology.

[3]  Matthew J. Brookes,et al.  Abnormal task driven neural oscillations in multiple sclerosis: A visuomotor MEG study , 2017, Human brain mapping.

[4]  Matthew J. Brookes,et al.  Source localisation in concurrent EEG/fMRI: Applications at 7T , 2009, NeuroImage.

[5]  Joachim Gross,et al.  Good practice for conducting and reporting MEG research , 2013, NeuroImage.

[6]  Siân E. Robson,et al.  Abnormal visuomotor processing in schizophrenia , 2015, NeuroImage: Clinical.

[7]  Svenja Knappe,et al.  Subpicotesla atomic magnetometry with a microfabricated vapour cell , 2007 .

[8]  M. Romalis,et al.  High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation. , 2002, Physical review letters.

[9]  Max A. Viergever,et al.  High frequency spectral components after Secobarbital: The contribution of muscular origin—A study with MEG/EEG , 2012, Epilepsy Research.

[10]  Matthew J. Brookes,et al.  Optimising experimental design for MEG beamformer imaging , 2008, NeuroImage.

[11]  Sepideh Hajipour Sardouie,et al.  Denoising of Ictal EEG Data Using Semi-Blind Source Separation Methods Based on Time-Frequency Priors , 2015, IEEE journal of biomedical and health informatics.

[12]  J. Vrba,et al.  Signal processing in magnetoencephalography. , 2001, Methods.

[13]  Marcus E Raichle,et al.  A Paradigm Shift in Functional Brain Imaging , 2009, The Journal of Neuroscience.

[14]  Dimitrios Pantazis,et al.  Coherent neural representation of hand speed in humans revealed by MEG imaging , 2007, Proceedings of the National Academy of Sciences.

[15]  R. Wakai,et al.  A compact, high performance atomic magnetometer for biomedical applications , 2013, Physics in medicine and biology.

[16]  V. Shah,et al.  Spin-exchange relaxation-free magnetometry using elliptically polarized light , 2009, 0903.2447.

[17]  Stephen D. Mayhew,et al.  Poststimulus undershoots in cerebral blood flow and BOLD fMRI responses are modulated by poststimulus neuronal activity , 2013, Proceedings of the National Academy of Sciences.

[18]  T. R. Carter,et al.  A 20-channel magnetoencephalography system based on optically pumped magnetometers. , 2017, Physics in medicine and biology.

[19]  Michael P. Weisend,et al.  Multi-sensor magnetoencephalography with atomic magnetometers , 2013, Physics in medicine and biology.

[20]  Mark W. Woolrich,et al.  Measuring functional connectivity in MEG: A multivariate approach insensitive to linear source leakage , 2012, NeuroImage.

[21]  T. W. Kornack,et al.  A subfemtotesla multichannel atomic magnetometer , 2003, Nature.

[22]  Sylvain Baillet,et al.  Magnetoencephalography for brain electrophysiology and imaging , 2017, Nature Neuroscience.

[23]  William Gaetz,et al.  Neuromagnetic imaging of movement-related cortical oscillations in children and adults: Age predicts post-movement beta rebound , 2010, NeuroImage.

[24]  Damien A. Fair,et al.  Development of large-scale functional networks from birth to adulthood: A guide to the neuroimaging literature , 2017, NeuroImage.

[25]  W. Drongelen,et al.  Localization of brain electrical activity via linearly constrained minimum variance spatial filtering , 1997, IEEE Transactions on Biomedical Engineering.

[26]  Matthew J. Brookes,et al.  Optimising experimental design for MEG resting state functional connectivity measurement , 2017, NeuroImage.

[27]  D. Cohen Magnetoencephalography: Detection of the Brain's Electrical Activity with a Superconducting Magnetometer , 1972, Science.

[28]  S. Haroche,et al.  Detection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances , 1969 .

[29]  Matthew J. Brookes,et al.  Measuring functional connectivity using MEG: Methodology and comparison with fcMRI , 2011, NeuroImage.

[30]  Svenja Knappe,et al.  Magnetoencephalography of Epilepsy with a Microfabricated Atomic Magnetrode , 2014, The Journal of Neuroscience.

[31]  J. Carlson,et al.  Design and evaluation of shielded gradient coils , 1992, Magnetic resonance in medicine.

[32]  M. Weisend,et al.  Magnetoencephalography with a two color pump-probe fiber-coupled atomic magnetometer. , 2010 .

[33]  Natsuhiko Mizutani,et al.  Human magnetoencephalogram measurements using newly developed compact module of high-sensitivity atomic magnetometer , 2015 .

[34]  Mathieu Bourguignon,et al.  Aging reduces experience-induced sensorimotor plasticity. A magnetoencephalographic study , 2015, NeuroImage.

[35]  M. Corbetta,et al.  Large-scale cortical correlation structure of spontaneous oscillatory activity , 2012, Nature Neuroscience.

[36]  Benjamin A. E. Hunt,et al.  Measuring electrophysiological connectivity by power envelope correlation: a technical review on MEG methods , 2015, Physics in medicine and biology.

[37]  Matthew J. Brookes,et al.  A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers , 2017, NeuroImage.

[38]  David Poeppel,et al.  Performance of an MEG adaptive-beamformer source reconstruction technique in the presence of additive low-rank interference , 2004, IEEE Transactions on Biomedical Engineering.

[39]  G. Backus,et al.  The Resolving Power of Gross Earth Data , 1968 .

[40]  E. Whitham,et al.  Scalp electrical recording during paralysis: Quantitative evidence that EEG frequencies above 20Hz are contaminated by EMG , 2007, Clinical Neurophysiology.

[41]  Richard Bowtell,et al.  Novel gradient coils designed using a boundary element method , 2007 .

[42]  R. Zimmermann,et al.  MEG and EEG show different sensitivity to myogenic artifacts. , 2004, Neurology & clinical neurophysiology : NCN.

[43]  Claude Cohen-Tannoudji,et al.  Diverses résonances de croisement de niveaux sur des atomes pompés optiquement en champ nul. I. Théorie , 1970 .

[44]  K. Yoda,et al.  Analytical design method of self‐shielded planar coils , 1990 .

[45]  W. Singer,et al.  Abnormal neural oscillations and synchrony in schizophrenia , 2010, Nature Reviews Neuroscience.

[46]  Hui Xia,et al.  Multi-channel atomic magnetometer for magnetoencephalography: A configuration study , 2014, NeuroImage.

[47]  Darren Price,et al.  Investigating the electrophysiological basis of resting state networks using magnetoencephalography , 2011, Proceedings of the National Academy of Sciences.

[48]  H. Berger Über das Elektrenkephalogramm des Menschen , 1938, Archiv für Psychiatrie und Nervenkrankheiten.

[49]  R. Ilmoniemi,et al.  Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain , 1993 .

[50]  Lutz Trahms,et al.  Magnetic field imaging with microfabricated optically-pumped magnetometers. , 2017, Optics express.

[51]  S. Muthukumaraswamy High-frequency brain activity and muscle artifacts in MEG/EEG: a review and recommendations , 2013, Front. Hum. Neurosci..

[52]  Roberto Hornero,et al.  Artifact Removal in Magnetoencephalogram Background Activity With Independent Component Analysis , 2007, IEEE Transactions on Biomedical Engineering.

[53]  J. Sarvas Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. , 1987, Physics in medicine and biology.

[54]  Matthew J. Brookes,et al.  Investigating spatial specificity and data averaging in MEG , 2010, NeuroImage.

[55]  Matthew J. Brookes,et al.  Does function fit structure? A ground truth for non-invasive neuroimaging , 2014, NeuroImage.