Laser diffractometry as a technique for the rapid assessment of aerosol particle size from inhalers.

The rapid assessment of aerosols produced by medicinal inhalers is highly desirable from several standpoints, including the assurance of product quality, the development of new delivery systems, and the need to meet an increasing requirement by regulatory bodies for reliable in vitro performance data. Particle size analysis has traditionally been undertaken by cascade impactor on account of the direct assessment of active pharmaceutical ingredient(s) (APIs) that is possible by this method. However, laser diffractometry is less labor-intensive, more rapid, and can be a less invasive procedure. The technique provides meaningful results; as long as precautions are taken to validate that the measurements are an accurate reflection of the distribution of API mass as a function of particle or droplet size. We begin the review by examining the underlying theory of the laser diffraction method. After a brief description of current laser diffractometers used in inhaler measurements, we continue by examining the range of applications by inhaler class. We then examine the basis upon which inhaler measurements made by laser-diffractometry can be compared with equivalent particle size distribution data from compendial techniques. We conclude the assessment of the technique by developing guidelines for its valid application as a component of the range of in vitro methods that are available for inhaler performance assessment.

[1]  Leopold P. Bayvel,et al.  Alternative Model‐Independent Inversion Programme for Malvern Particle Sizer , 1987 .

[2]  J. Mitchell,et al.  Time-of-flight aerodynamic particle size analyzers: their use and limitations for the evaluation of medical aerosols. , 1999, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[3]  A. Clark The use of laser diffraction for the evaluation of the aerosol clouds generated by medical nebulizers , 1995 .

[4]  Norman Chigier,et al.  Response Characteristics Of Laser Diffraction Particle Size Analyzers: Optical Sample Volume Extent And Lens Effects , 1984 .

[5]  Paul Kippax,et al.  Appraisal of the laser diffraction particle-sizing technique , 2005 .

[6]  L. Borgström,et al.  In Vitro Testing of Pharmaceutical Aerosols and Predicting Lung Deposition from In Vitro Measurements , 2001 .

[7]  P. Diot,et al.  Validation of laser diffraction method as a substitute for cascade impaction in the European Project for a Nebulizer Standard. , 2001, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[8]  A. G. Demusyak International Standards Organization (ISO) , 1967 .

[9]  Jim Swithenbank,et al.  A Laser Diagnostic Technique for the Measurement of Droplet and Particle Size Distributions , 1976 .

[10]  Hugh D. C. Smyth,et al.  Multimodal particle size distributions emitted from HFA-134a solution pressurized metered-dose inhalers , 2003, AAPS PharmSciTech.

[11]  A. Hickey Inhalation aerosols : physical and biological basis for therapy , 2006 .

[12]  C. Camargo,et al.  Consensus statement: aerosols and delivery devices. , 2000, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[13]  Z. Kam,et al.  Absorption and Scattering of Light by Small Particles , 1998 .

[14]  P Hagedoorn,et al.  Characterization of inhalation aerosols: a critical evaluation of cascade impactor analysis and laser diffraction technique. , 2002, International journal of pharmaceutics.

[15]  M. Vidgrén,et al.  Nasal delivery systems and their effect on deposition and absorption. , 1998, Advanced drug delivery reviews.

[16]  D. Grant,et al.  Metered Dose Inhaler Technology , 1997 .

[17]  Magnus Svartengren,et al.  Basic Principles of Particle Behavior in the Human Respiratory Tract , 2001 .

[18]  D. Hess,et al.  Nebulizers: principles and performance. , 2000, Respiratory care.

[19]  Gerald C. Smaldone,et al.  Drug Delivery to the Lung , 2001 .

[20]  Jolyon P. Mitchell,et al.  Particle Size Analysis of Aerosols from Medicinal Inhalers , 2004 .

[21]  H. Frijlink,et al.  In Vitro Performance Testing of the Novel Medspray® Wet Aerosol Inhaler Based on the Principle of Rayleigh Break-up , 2007, Pharmaceutical Research.

[22]  N. Chigier,et al.  OPTICAL MEASUREMENT OF NEBULIZER SPRAYS: A QUANTITATIVE COMPARISON OF DIFFRACTION, PHASE DOPPLER INTERFEROMETRY, AND TIME OF FLIGHT TECHNIQUES , 2000 .

[23]  Klaus Willeke,et al.  Aerosol Measurement: Principles, Techniques, and Applications , 2001 .

[24]  Wolfgang Witt,et al.  Laser Diffraction – Unlimited? , 1996 .

[25]  B. Laube,et al.  Comparison of Nasal Deposition and Clearance of Aerosol Generated by a Nebulizer and an Aqueous Spray Pump , 1999, Pharmaceutical Research.

[26]  Jolyon P. Mitchell,et al.  Particle Standards: Their Development and Application , 2000 .

[27]  G. Gee,et al.  Particle-size Analysis , 2018, SSSA Book Series.

[28]  Mandip Singh,et al.  Evaluation of the Malvern Spraytec with inhalation cell for the measurement of particle size distribution from metered dose inhalers. , 2004, Journal of pharmaceutical sciences.

[29]  W. Bachalo,et al.  Phase/Doppler Spray Analyzer For Simultaneous Measurements Of Drop Size And Velocity Distributions , 1984 .

[30]  Dieter Hochrainer,et al.  Next generation pharmaceutical impactor (a new impactor for pharmaceutical inhaler testing). Part I: Design. , 2003, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[31]  M. Goldenberg,et al.  Micrometer-Scale Particle Sizing by Laser Diffraction: Critical Impact of the Imaginary Component of Refractive Index , 2005, Pharmaceutical Research.

[32]  H. V. Hulst Light Scattering by Small Particles , 1957 .

[33]  O. Thas,et al.  Determination of the Refractive Index of Water‐dispersible Granules for Use in Laser Diffraction Experiments , 2002 .

[34]  A. Coates,et al.  Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus Andersen cascade impactor and low-flow Marple personal cascade impactor. , 2000, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[35]  C. Camargo,et al.  Consensus statement: aerosols and delivery devices. American Association for Respiratory Care. , 2000, Respiratory care.

[36]  J. Mitchell,et al.  Size analysis of a pressurized metered dose inhaler-delivered suspension formulation by the API Aerosizer time-of-flight aerodynamic particle size analyzer. , 1999, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[37]  Jolyon P Mitchell,et al.  Cascade impactors for the size characterization of aerosols from medical inhalers: their uses and limitations. , 2003, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[38]  C. Washington Particle Size Analysis in Inhalation Therapy , 1997 .

[39]  H. Lennernäs,et al.  Miniaturized nebulization catheters: a new approach for delivery of defined aerosol doses to the rat lung. , 2002, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[40]  W. Finlay,et al.  Errors in characterizing nebulized particle size distributions with cascade impactors. , 1998, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[41]  Jolyon P. Mitchell,et al.  An in vitro study to investigate the use of a breath-actuated, small-volume, pneumatic nebulizer for the delivery of methacholine chloride bronchoprovocation agent. , 2003, Respiratory care.

[42]  W. Witt,et al.  Design and application of a new modular adapter for laser diffraction characterization of inhalation aerosols. , 2002, International journal of pharmaceutics.

[43]  J. Fink,et al.  Metered-dose inhalers, dry powder inhalers, and transitions. , 2000, Respiratory care.

[44]  H. Hansson,et al.  Why do medical nebulizers differ in their output and particle size characteristics? , 1994, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[45]  Beth L. Laube,et al.  Validity of in Vitro Tests on Aqueous Spray Pumps as Surrogates for Nasal Deposition , 2004, Pharmaceutical Research.

[46]  Ananth Annapragada,et al.  An analysis of the fraunhofer diffraction method for particle size distribution analysis and its application to aerosolized sprays , 1996 .