Evaluation on different sampling schemes for assessing indoor radon level in Hong Kong

In order to maintain an acceptable indoor air quality (IAQ), policies, strategies and guidelines on achieving the required IAQ have been developed worldwide. In Hong Kong, the Environmental Protection Department (HKEPD) has launched an IAQ certification scheme to promote an acceptable IAQ in workplaces. For the practical radon measurement, an 8-h continuous monitoring is proposed for the assessment purpose. However, the uncertainties and measurement efforts associated with the method have not been detailed. In this study, the probable errors and measurement efforts in measuring the indoor radon concentration by three proposed sampling schemes of various sampling periods have been investigated. Scheme A is to obtain an average concentration over a sampling period in an occupied period; Scheme B is to obtain an average concentration in two sampling periods from two sessions of the occupied period; and for Scheme C, the average concentration in two structural sampling periods from two sessions of the occupied period. In particular, a 1-year measurement of indoor radon concentration in a typical office building has been used as basis to evaluate the probable errors between the long-term average and those obtained by the three measurement schemes. At a certain confidence level, the results show that the measurement time required for Schemes B and C could be reduced significantly, when compared with Scheme A using continuous monitoring. It is recommended to specify the measurement uncertainty and effort in future codes, and the sampling schemes could be considered in determining the practical strategies for radon measurement.

[1]  Tosihiro Oka,et al.  Ranking the risks of 12 major environmental pollutants that occur in Japan. , 2003, Chemosphere.

[2]  I. C. Ward,et al.  Radon entry, migration and reduction in houses with cellars , 2002 .

[3]  Wan Ki Chow,et al.  Field measurement of the air flow characteristics of big mechanically ventilated spaces , 1996 .

[4]  Thomas Lindvall,et al.  Effects of Indoor Air Pollution on Human Health , 1992 .

[5]  Christian Monn,et al.  Exposure assessment of air pollutants: a review on spatial heterogeneity and indoor/outdoor/personal exposure to suspended particulate matter, nitrogen dioxide and ozone , 2001 .

[6]  Mark Stamp,et al.  A note on the error in gaussian quadrature , 1992 .

[7]  A comparison of the variability of different techniques and sampling periods for measuring 222Rn and its decay products. , 1988, Health physics.

[8]  Roger A. Pielke The need to assess uncertainty in air quality evaluations , 1998 .

[9]  T. Martı́nez,et al.  Relationship between short and long term radon measurements , 2001 .

[10]  C. K. Man,et al.  Variations of outdoor radon concentrations in Hong Kong , 1998 .

[11]  F. Haghighat,et al.  Material emission rates: Literature review, and the impact of indoor air temperature and relative humidity , 1998 .

[12]  John Burnett,et al.  Influence of ventilation on indoor radon level , 1997 .

[13]  Chris Cameron Relative efficiency of Gaussian stochastic process sampling procedures , 2003 .

[14]  D. Gatz,et al.  The standard error of a weighted mean concentration—II. Estimating confidence intervals , 1995 .

[15]  C. Muirhead Uncertainties in assessing health risks from natural radiation, including radon , 2002 .

[16]  R. C. Ramola,et al.  A study of seasonal variations of radon levels in different types of houses , 1998 .

[17]  M. Y. Tso,et al.  Radon release from building materials in Hong Kong. , 1994, Health physics.

[18]  C. Chao,et al.  Development of a dual-mode demand control ventilation strategy for indoor air quality control and energy saving , 2004 .

[19]  K. Siddappa,et al.  Seasonal variation of indoor radon levels in coastal Karnataka on the south-west coast of India , 1998 .

[20]  C. Baixeras,et al.  Uncertainty, variability and sensitivity analysis applied to the RAGENA model of radon generation, entry and accumulation indoors. , 2001, The Science of the total environment.

[21]  J. Rydock,et al.  Diurnal variations in radon concentrations in a school and office:: implications for determining radon exposure in day-use buildings , 2001 .

[22]  D. Steck A comparison of EPA screening measurements and annual 222Rn concentrations in statewide surveys. , 1990, Health physics.

[23]  R. Harrison,et al.  Volatile organic compounds in indoor air , 1995 .

[24]  Concentration variations of pollutants in a work week period of an office , 1997 .

[25]  Wan Ki Chow,et al.  Preliminary studies on a new method for assessing ventilation in large spaces , 2002 .

[26]  Guk-Rwang Won American Society for Testing and Materials , 1987 .