Joint motion control of a powered lower limb orthosis for rehabilitation

Many patients with spinal injures are confined to wheelchairs, leading to a sedentary lifestyle with secondary pathologies and increased dependence on a carer. Increasing evidence has shown that locomotor training reduces the incidence of these secondary pathologies, but the physical effort involved in this training is such that there is poor compliance. This paper reports on the design and control of a new “human friendly” orthosis (exoskeleton), powered by high power pneumatic Muscle Actuators (pMAs). The combination of a highly compliant actuation system, with an intelligent embedded control mechanism which senses hip, knee, and ankle positions, velocity, acceleration and force, produces powerful yet inherently safe operation for paraplegic patients. This paper analyzes the motion of ankle, knee, and hip joints under zero loading, and loads which simulate human limb mass, showing that the use of “soft” actuators can provide a smooth user friendly motion. The application of this technology will greatly improve the rehabilitative protocols for paraplegic patients.

[1]  E Byron Marsolais,et al.  Electronic Orthoses: Technology, Prototypes, and Practices , 1988 .

[2]  E Genda,et al.  A new walking orthosis for paraplegics: hip and ankle linkage system , 2004, Prosthetics and orthotics international.

[3]  E. Marsolais,et al.  Functional electrical stimulation for walking in paraplegia. , 1987, The Journal of bone and joint surgery. American volume.

[4]  M. Granat,et al.  A knee and ankle flexing hybrid orthosis for paraplegic ambulation. , 2003, Medical engineering & physics.

[5]  Fin Biering-Sørensen,et al.  The use of long leg calipers for paraplegic patients: a follow-up study of patients discharged 1973–82 , 1996, Spinal Cord.

[6]  Nikolaos G. Tsagarakis,et al.  Enhanced Modelling and Performance in Braided Pneumatic Muscle Actuators , 2003, Int. J. Robotics Res..

[7]  Jrg Kaiser,et al.  Nonrecursive digital filter design using the I-sinh window function , 1977 .

[8]  Laura Gastaldi,et al.  Pneumatic active gait orthosis , 2001 .

[9]  Janaf Human Engineering Guide to Equipment Design , 1984 .

[10]  Ng Tsagarakis Integrated haptic interface: Tactile and force feedback for improved realism in VR and telepresence applications. , 2000 .

[11]  J W GERSTEN,et al.  ENERGY COST OF AMBULATION IN THE TRAUMATIC PARAPLEGIC , 1964, American journal of physical medicine.

[12]  John Kenneth Salisbury,et al.  A New Actuation Approach for Human Friendly Robot Design , 2002, ISER.

[13]  A. W. M. van den Enden,et al.  Discrete Time Signal Processing , 1989 .

[14]  O. Kameyama,et al.  Newly designed computer controlled knee-ankle-foot orthosis (Intelligent Orthosis) , 1998, Prosthetics and orthotics international.

[15]  Michael R. Zinn,et al.  A New Actuation Approach for Human Friendly Robot Design , 2004, Int. J. Robotics Res..

[16]  R. Waters,et al.  Energy cost of paraplegic locomotion. , 1985, The Journal of bone and joint surgery. American volume.

[17]  Alan V. Oppenheim,et al.  Selected papers in digital signal processing, II , 1976 .

[18]  Darwin G. Caldwell,et al.  Control of pneumatic muscle actuators , 1995 .

[19]  N Chino,et al.  Clinical experience with a new hip-knee-ankle-foot orthotic system using a medial single hip joint for paraplegic standing and walking. , 1996, American journal of physical medicine & rehabilitation.

[20]  R. W. Wirta,et al.  Energy‐Efficient Knee‐Ankle-Foot Orthosis: A Case Study , 1996 .