Electroosmotic Flow, Ionic Currents, and Pressure-Induced Flow in Microsystem Channel Networks: NMR Mapping and Computational Fluid Dynamics Simulations

Abstract.Using nuclear magnetic resonance (NMR) velocity mapping and NMR current density mapping as well as finite-element computational fluid dynamics methods, transport in microsystem electrolytic cells with increasing complexity has been examined ranging from single straight channels to random-site percolation clusters. This sort of system is considered as paradigm for more or less complex devices in microsystem technology. Corresponding model objects were designed on a computer and milled into ceramic (polar) or polystyrene (nonpolar) matrices. The pore space was filled with electrolyte solutions. Maps of the following quantities were recorded: velocity of hydrodynamic flow driven by external pressure gradients, velocity of electroosmotic flow (EOF), ionic current density in the presence of EOF, ionic current density in the absence of EOF. As far as possible, the experiments were supplemented by computational fluid dynamics simulations. It is shown that EOF, as well as the electric current, leads to recirculation patterns in closed complex structures such as percolation clusters. Remarkably, all transport patterns turned out to be dissimilar, and the occurrence and positions of eddies do not coincide in the different maps. Velocity histograms and the mean velocity as a function of the porosity have been evaluated. An EOF percolation transition is found at the geometrical percolation threshold. The combined application of NMR techniques for the quantitative, noninvasive visualization of the total variety of hydroand electrodynamics in the same channel system promises to become a powerful tool for design purposes in microsystem technology.

[1]  S. Redner,et al.  Introduction To Percolation Theory , 2018 .

[2]  R. W. O'Brien Electroosmosis in porous materials , 1986 .

[3]  R. Henkelman,et al.  Sensitivity of magnetic-resonance current-density imaging , 1992 .

[4]  I. Serša,et al.  Magnetic Resonance Microscopy of Electric Currents , 1994 .

[5]  Charles S. Johnson,et al.  Flow Imaging by Means of 1D Pulsed-Field-Gradient NMR with Application to Electroosmotic Flow , 1995 .

[6]  P. Callaghan,et al.  NMR Imaging of the Time Evolution of Electroosmotic Flow in a Capillary , 1995 .

[7]  A. Rathore,et al.  Capillary electrochromatography: theories on electroosmotic flow in porous media. , 1997, Journal of chromatography. A.

[8]  Howard H. Hu,et al.  Numerical simulation of electroosmotic flow. , 1998, Analytical chemistry.

[9]  Dennis C. Ghiglia,et al.  Two-Dimensional Phase Unwrapping: Theory, Algorithms, and Software , 1998 .

[10]  S. K. Griffiths,et al.  Conditions for similitude between the fluid velocity and electric field in electroosmotic flow , 1999, Analytical chemistry.

[11]  R. Wu Electroosmotic flow through porous media: cylindrical and annular models , 2000 .

[12]  Rapp,et al.  Electroosmotic and pressure-driven flow in open and packed capillaries: velocity distributions and fluid dispersion , 2000, Analytical chemistry.

[13]  R. Kimmich NMR: Tomography, Diffusometry, Relaxometry , 2001 .

[14]  B. Locke,et al.  Electro-Osmotic Flow in Porous Media Using Magnetic Resonance Imaging , 2001 .

[15]  R. Kimmich,et al.  Flow through percolation clusters: NMR velocity mapping and numerical simulation study. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[16]  R. Kimmich,et al.  Maps of electric current density and hydrodynamic flow in porous media: NMR experiments and numerical simulations. , 2002, Physical review. E, Statistical, nonlinear, and soft matter physics.

[17]  Rayleigh-Bénard percolation transition of thermal convection in porous media: computational fluid dynamics, NMR velocity mapping, NMR temperature mapping. , 2002, Physical review. E, Statistical, nonlinear, and soft matter physics.

[18]  J. Alam,et al.  Energy-Conserving Simulation of Incompressible Electro-Osmotic and Pressure-Driven Flow , 2002 .

[19]  J. Santiago,et al.  Porous glass electroosmotic pumps: theory. , 2003, Journal of colloid and interface science.

[20]  Y. Takamura,et al.  Low‐voltage electroosmosis pump for stand‐alone microfluidics devices , 2003, Electrophoresis.

[21]  Dongqing Li Electrokinetics in Microfluidics , 2004 .

[22]  David Sinton,et al.  Microscale flow visualization , 2004 .

[23]  Flow measurements below 50 mum: NMR microscopy experiments in lithographic model pore spaces. , 2005, Magnetic resonance imaging.

[24]  S. J. Singer,et al.  Electro-osmotic flow of a model electrolyte. , 2005, Physical review. E, Statistical, nonlinear, and soft matter physics.

[25]  N. Nguyen,et al.  Visualizing the transient electroosmotic flow and measuring the zeta potential of microchannels with a micro-PIV technique. , 2006, The Journal of chemical physics.

[26]  Dissimilar electro-osmotic flow and ionic current recirculation patterns in porous media detected by NMR mapping experiments. , 2006, Physical review letters.

[27]  Salah Karout,et al.  Two-dimensional phase unwrapping , 2007 .