A Coupled Magnetoelastic Strain Sensor Array for Guiding and Monitoring Hernia Repairs

Objective: Ventral hernia repairs using mesh prosthetics suffer from high recurrence rates, with 10%–20% of repairs failing within three years. Uneven distribution of stress within the implanted mesh prosthetic is thought to contribute to the high recurrence rate. We propose a method for providing quantitative guidance and monitoring of hernia repairs using an array of magnetoelastic strain sensors. Methods: The magnetoelastic strain sensors presented here are based on a coupled design to achieve measurements with higher signal-to-noise ratio (SNR). A first magnetoelastic element (the transducer) is bonded to the mesh prosthetic and is characterized by a strain-dependent magnetic field. The resonance frequency of a second magnetoelastic element (the resonator) encased in a rigid casing is biased by the transducer element's magneticity and can be measured noninvasively using an external interrogation coil. The coupled magnetoelastic strain sensors are assembled using a combination of photochemical machining, patterning, and heat sealing. Results: The dynamic range of the coupled sensors can be tuned by altering the transducer geometry. Additional spring elements are integrated onto the transducer element to achieve high dynamic range measurements saturating at 74 millistrains. Conclusion: A coupled magnetoelastic strain sensor combines a transducer with an encased resonator element to measure strain with high SNR on an implantable flexible hernia mesh substrate. Significance: This study provides surgeons and researchers with a clinically relevant tool to quantify the strain distributions within implanted mesh prosthetics, with the ultimate goal of reducing the recurrence rate of ventral hernia repairs.

[1]  Wen H. Ko,et al.  Early History and Challenges of Implantable Electronics , 2012, JETC.

[2]  Jungmin Kim,et al.  Thickness of Rectus Abdominis Muscle and Abdominal Subcutaneous Fat Tissue in Adult Women: Correlation with Age, Pregnancy, Laparotomy, and Body Mass Index , 2012, Archives of plastic surgery.

[3]  A. Sanchez,et al.  Demagnetizing factors for rectangular prisms , 2005, IEEE Transactions on Magnetics.

[4]  T. Robinson,et al.  Major mesh-related complications following hernia repair: events reported to the Food and Drug Administration. , 2005, Surgical endoscopy.

[5]  Aphrodite Ktena,et al.  Magnetostriction and magnetostrictive materials for sensing applications , 2007 .

[6]  Keat Ghee Ong,et al.  Biodegradation and biocompatibility of mechanically active magnetoelastic materials , 2014 .

[7]  A. Kersey A Review of Recent Developments in Fiber Optic Sensor Technology , 1996 .

[8]  D. E. Mouzakis,et al.  A 2826 MB Metglas ribbon as a strain sensor for remote and dynamic mechanical measurements , 2006 .

[9]  Cynthia S Crowson,et al.  Prevalence of Total Hip and Knee Replacement in the United States. , 2015, The Journal of bone and joint surgery. American volume.

[10]  Michel M. Maharbiz,et al.  Integrating coupled magnetoelastic sensors onto a flexible hernia mesh for high dynamic range strain measurements , 2017, 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[11]  Y. Gianchandani,et al.  Wireless Magnetoelastic Monitoring of Biliary Stents , 2009, Journal of Microelectromechanical Systems.

[12]  G. Gillian,et al.  Laparoscopic Incisional and Ventral Hernia Repair (LIVH): An Evolving Outpatient Technique , 2002, JSLS : Journal of the Society of Laparoendoscopic Surgeons.

[13]  M. Maher,et al.  Adult abdominal hernias. , 2014, AJR. American journal of roentgenology.

[14]  Bernhard Weisse,et al.  Magnetoelastic Strain Sensor for Optimized Assessment of Bone Fracture Fixation , 2009, IEEE Sensors Journal.

[15]  Christoph Vogler,et al.  Magnetoelastic resonance sensor for remote strain measurements , 2012 .

[16]  J. Jeekel,et al.  A comparison of suture repair with mesh repair for incisional hernia. , 2000, The New England journal of medicine.

[17]  S. K. Guha,et al.  Transmission of time varying magnetic field through body tissue , 1975 .

[18]  Craig A. Grimes,et al.  Wireless Magnetoelastic Resonance Sensors: A Critical Review , 2002 .

[19]  Yogesh B. Gianchandani,et al.  Microfabricated magnetoelastic sensors and actuators: Opportunities and challenges , 2015, 2015 IEEE SENSORS.

[20]  Yogesh B. Gianchandani,et al.  Passive Wireless Strain Sensors Using Microfabricated Magnetoelastic Beam Elements , 2014, Journal of Microelectromechanical Systems.

[21]  S. Phillips,et al.  Epidemiology and cost of ventral hernia repair: making the case for hernia research , 2012, Hernia.

[22]  C. N. Brown,et al.  Which mesh for hernia repair? , 2010, Annals of the Royal College of Surgeons of England.

[23]  I. Park,et al.  Stretchable, Skin‐Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review , 2016 .

[24]  T. Koepsell,et al.  Have Outcomes of Incisional Hernia Repair Improved With Time?: A Population-Based Analysis , 2003, Annals of surgery.

[25]  Mike R. J. Gibbs,et al.  A micromachined magnetostrictive pressure sensor using magneto-optical interrogation , 2000 .

[26]  K. LeBlanc,et al.  Hernias: inguinal and incisional , 2003, The Lancet.

[27]  Y. Gianchandani,et al.  Photochemically Patterned Biliary Stents with Integrated Permanent Magnets and Deformable Assembly Features for Wireless Magnetoelastic Tissue Growth Sensing , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[28]  Craig A. Grimes,et al.  Theory, Instrumentation and Applications of Magnetoelastic Resonance Sensors: A Review , 2011, Sensors.

[29]  Yogesh B. Gianchandani,et al.  Resonant magnetoelastic microstructures for wireless actuation of liquid flow on 3D surfaces and use in glaucoma drainage implants , 2015, Microsystems & Nanoengineering.

[30]  D. Mitton,et al.  Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair. , 2014, Journal of the mechanical behavior of biomedical materials.

[31]  J. Jeekel,et al.  Evaluation of new prosthetic meshes for ventral hernia repair , 2006, Surgical Endoscopy And Other Interventional Techniques.

[32]  A. Waas,et al.  Three-dimensional digital image correlation technique using single high-speed camera for measuring large out-of-plane displacements at high framing rates. , 2010, Applied optics.