The VAMPIRE challenge: A multi‐institutional validation study of CT ventilation imaging

PURPOSE CT ventilation imaging (CTVI) is being used to achieve functional avoidance lung cancer radiation therapy in three clinical trials (NCT02528942, NCT02308709, NCT02843568). To address the need for common CTVI validation tools, we have built the Ventilation And Medical Pulmonary Image Registration Evaluation (VAMPIRE) Dataset, and present the results of the first VAMPIRE Challenge to compare relative ventilation distributions between different CTVI algorithms and other established ventilation imaging modalities. METHODS The VAMPIRE Dataset includes 50 pairs of 4DCT scans and corresponding clinical or experimental ventilation scans, referred to as reference ventilation images (RefVIs). The dataset includes 25 humans imaged with Galligas 4DPET/CT, 21 humans imaged with DTPA-SPECT, and 4 sheep imaged with Xenon-CT. For the VAMPIRE Challenge, 16 subjects were allocated to a training group (with RefVI provided) and 34 subjects were allocated to a validation group (with RefVI blinded). Seven research groups downloaded the Challenge dataset and uploaded CTVIs based on deformable image registration (DIR) between the 4DCT inhale/exhale phases. Participants used DIR methods broadly classified into B-splines, Free-form, Diffeomorphisms, or Biomechanical modeling, with CT ventilation metrics based on the DIR evaluation of volume change, Hounsfield Unit change, or various hybrid approaches. All CTVIs were evaluated against the corresponding RefVI using the voxel-wise Spearman coefficient r S , and Dice similarity coefficients evaluated for low function lung ( DSC low ) and high function lung ( DSC high ). RESULTS A total of 37 unique combinations of DIR method and CT ventilation metric were either submitted by participants directly or derived from participant-submitted DIR motion fields using the in-house software, VESPIR. The r S and DSC results reveal a high degree of inter-algorithm and intersubject variability among the validation subjects, with algorithm rankings changing by up to ten positions depending on the choice of evaluation metric. The algorithm with the highest overall cross-modality correlations used a biomechanical model-based DIR with a hybrid ventilation metric, achieving a median (range) of 0.49 (0.27-0.73) for r S , 0.52 (0.36-0.67) for DSC low , and 0.45 (0.28-0.62) for DSC high . All other algorithms exhibited at least one negative r S value, and/or one DSC value less than 0.5. CONCLUSIONS The VAMPIRE Challenge results demonstrate that the cross-modality correlation between CTVIs and the RefVIs varies not only with the choice of CTVI algorithm but also with the choice of RefVI modality, imaging subject, and the evaluation metric used to compare relative ventilation distributions. This variability may arise from the fact that each of the different CTVI algorithms and RefVI modalities provides a distinct physiologic measurement. Ultimately this variability, coupled with the lack of a "gold standard," highlights the ongoing importance of further validation studies before CTVI can be widely translated from academic centers to the clinic. It is hoped that the information gleaned from the VAMPIRE Challenge can help inform future validation efforts.

[1]  Daniel R Einstein,et al.  Comparison of CT-derived ventilation maps with deposition patterns of inhaled microspheres in rats , 2015, Experimental lung research.

[2]  Sven Kabus,et al.  CT ventilation functional image-based IMRT treatment plans are comparable to SPECT ventilation functional image-based plans. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Tomas Kron,et al.  High-resolution imaging of pulmonary ventilation and perfusion with 68Ga-VQ respiratory gated (4-D) PET/CT , 2013, European Journal of Nuclear Medicine and Molecular Imaging.

[4]  Jean-Mathieu Beauregard,et al.  68Ga PET/CT Ventilation–Perfusion Imaging for Pulmonary Embolism: A Pilot Study with Comparison to Conventional Scintigraphy , 2011, The Journal of Nuclear Medicine.

[5]  Paul Keall,et al.  Evaluating the accuracy of 4D‐CT ventilation imaging: First comparison with Technegas SPECT ventilation , 2017, Medical physics.

[6]  Kai Ding,et al.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements. , 2013, Medical physics.

[7]  K. Brock,et al.  Accuracy of finite element model-based multi-organ deformable image registration. , 2005, Medical physics.

[8]  Bastiaan Driehuys,et al.  Correlation of Regional Lung Ventilation and Gas Transfer to Red Blood Cells: Implications for Functional-Avoidance Radiation Therapy Planning. , 2018, International journal of radiation oncology, biology, physics.

[9]  Paul J Keall,et al.  Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using 68Ga-labeled nanoparticles. , 2013, Medical physics.

[10]  J M Wild,et al.  Functional Image-guided Radiotherapy Planning for Normal Lung Avoidance. , 2016, Clinical oncology (Royal College of Radiologists (Great Britain)).

[11]  Thomas Guerrero,et al.  Clinical validation of 4-dimensional computed tomography ventilation with pulmonary function test data. , 2015, International journal of radiation oncology, biology, physics.

[12]  Kai Ding,et al.  Comparison of image registration based measures of regional lung ventilation from dynamic spiral CT with Xe-CT. , 2012, Medical physics.

[13]  Brian B. Avants,et al.  Evaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge , 2011, IEEE Transactions on Medical Imaging.

[14]  Thomas Guerrero,et al.  The numerical stability of transformation-based CT ventilation , 2017, International Journal of Computer Assisted Radiology and Surgery.

[15]  K. Brock,et al.  Use of image registration and fusion algorithms and techniques in radiotherapy: Report of the AAPM Radiation Therapy Committee Task Group No. 132 , 2017, Medical physics.

[16]  Thomas Guerrero,et al.  Hyperpolarized (3)He magnetic resonance imaging: comparison with four-dimensional x-ray computed tomography imaging in lung cancer. , 2012, Academic radiology.

[17]  F. Namazi,et al.  Artifacts and Anatomical Variants Affecting Ventilation and Perfusion Lung Imaging , 2016 .

[18]  Paul J Keall,et al.  CT ventilation imaging derived from breath hold CT exhibits good regional accuracy with Galligas PET. , 2017, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  Cristian Lorenz,et al.  Evaluation of Four-dimensional ( 4 D ) Computed Tomography ( CT ) Pulmonary Ventilation Imaging by Comparison with Single Photon Emission Computed Tomography ( SPECT ) Scans for a Lung Cancer Patient , 2010 .

[20]  K. Brock Results of a multi-institution deformable registration accuracy study (MIDRAS). , 2010, International journal of radiation oncology, biology, physics.

[21]  Tinsu Pan,et al.  Dynamic ventilation imaging from four-dimensional computed tomography , 2006, Physics in medicine and biology.

[22]  Kai Ding,et al.  Reproducibility of intensity-based estimates of lung ventilation. , 2013, Medical physics.

[23]  Sean Pollock,et al.  Measurement of preoperative lobar lung function with computed tomography ventilation imaging: progress towards rapid stratification of lung cancer lobectomy patients with abnormal lung function. , 2016, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[24]  Cristian Lorenz,et al.  Pulmonary ventilation imaging based on 4-dimensional computed tomography: comparison with pulmonary function tests and SPECT ventilation images. , 2014, International journal of radiation oncology, biology, physics.

[25]  David W. Kaczka,et al.  What can computed tomography and magnetic resonance imaging tell us about ventilation? , 2012, Journal of applied physiology.

[26]  Paul J Keall,et al.  Estimating lung ventilation directly from 4D CT Hounsfield unit values. , 2015, Medical physics.

[27]  Moyed Miften,et al.  Evaluating Which Dose-Function Metrics Are Most Critical for Functional-Guided Radiation Therapy. , 2017, International journal of radiation oncology, biology, physics.

[28]  Paul J. Keall,et al.  New pathways for end-to-end validation of CT ventilation imaging (CTVI) using deformable image registration , 2016, 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI).

[29]  Chun-Chien Shieh,et al.  Quantifying the reproducibility of lung ventilation images between 4‐Dimensional Cone Beam CT and 4‐Dimensional CT , 2017, Medical physics.

[30]  K. Brock,et al.  Biomechanical deformable image registration of longitudinal lung CT images using vessel information , 2016, Physics in medicine and biology.

[31]  Stina Svensson,et al.  The ANACONDA algorithm for deformable image registration in radiotherapy. , 2014, Medical physics.

[32]  S. Kabus,et al.  The first patient treatment of computed tomography ventilation functional image-guided radiotherapy for lung cancer. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[33]  Tomas Kron,et al.  A prospective observational study of Gallium-68 ventilation and perfusion PET/CT during and after radiotherapy in patients with non-small cell lung cancer , 2014, BMC Cancer.

[34]  Cristian Lorenz,et al.  Four-dimensional computed tomography pulmonary ventilation images vary with deformable image registration algorithms and metrics. , 2011, Medical physics.

[35]  Eric A. Hoffman,et al.  Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation , 2008, Medical Image Anal..

[36]  Gregory C Sharp,et al.  Scale invariant feature transform in adaptive radiation therapy: a tool for deformable image registration assessment and re-planning indication , 2013, Physics in medicine and biology.

[37]  Thomas Guerrero,et al.  Comparison of 4-dimensional computed tomography ventilation with nuclear medicine ventilation-perfusion imaging: a clinical validation study. , 2014, International journal of radiation oncology, biology, physics.

[38]  Helen Marshall,et al.  Spatial Comparison of CT-Based Surrogates of Lung Ventilation With Hyperpolarized Helium-3 and Xenon-129 Gas MRI in Patients Undergoing Radiation Therapy. , 2018, International journal of radiation oncology, biology, physics.