Accurate Measurement in Doppler Radar Vital Sign Detection Based on Parameterized Demodulation

Utilizing Doppler radar to conduct noncontact vital sign detection has attracted growing interest in recent years. Aiming to extract the vital sign information from the baseband signal effectively and accurately, a novel signal processing method based on parameterized demodulation (PD) is proposed. To effectively characterize the baseband signal whose phase consists of two oscillating components (i.e., the respiration and heartbeat components), the proposed algorithm defines a demodulation operator with sine kernel functions and formulates the phase demodulation as a parameter optimization problem. To increase the computational efficiency of the algorithm, the parameters corresponding to the respiration and heartbeat components are estimated sequentially. Specifically, the respiration component is first estimated and removed from the phase of the baseband signal, and then, the heartbeat component is extracted from the residual signal. Compared with the existing methods, the proposed algorithm is free of the resolution problem in fast Fourier transform-based methods with a limited data length and can obtain accurate rate tracking in a noisy environment. Both simulated and experimental results are provided to demonstrate the advantages and effectiveness of the proposed method for accurate noncontact vital sign detection.

[1]  Paul Leroux,et al.  Analysis of an Indoor Biomedical Radar-Based System for Health Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[2]  Jenshan Lin,et al.  Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.

[3]  Kexiang Wei,et al.  Time-Varying Frequency-Modulated Component Extraction Based on Parameterized Demodulation and Singular Value Decomposition , 2016, IEEE Transactions on Instrumentation and Measurement.

[4]  Xiaomeng Gao,et al.  Data-Based Quadrature Imbalance Compensation for a CW Doppler Radar System , 2013, IEEE Transactions on Microwave Theory and Techniques.

[5]  Changzhi Li,et al.  Random Body Movement Cancellation in Doppler Radar Vital Sign Detection , 2008, IEEE Transactions on Microwave Theory and Techniques.

[6]  A. Singh,et al.  Respiratory Monitoring and Clutter Rejection Using a CW Doppler Radar With Passive RF Tags , 2012, IEEE Sensors Journal.

[7]  Yang Yang,et al.  Component Extraction for Non-Stationary Multi-Component Signal Using Parameterized De-chirping and Band-Pass Filter , 2015, IEEE Signal Processing Letters.

[8]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[9]  Jingyu Wang,et al.  Noncontact Distance and Amplitude-Independent Vibration Measurement Based on an Extended DACM Algorithm , 2014, IEEE Transactions on Instrumentation and Measurement.

[10]  Steve B. Jiang,et al.  Accurate Respiration Measurement Using DC-Coupled Continuous-Wave Radar Sensor for Motion-Adaptive Cancer Radiotherapy , 2012, IEEE Transactions on Biomedical Engineering.

[11]  Yong Huang,et al.  Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier , 2000, IEEE Transactions on Biomedical Engineering.

[12]  Byung-Kwon Park,et al.  Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems , 2007, IEEE Transactions on Microwave Theory and Techniques.

[13]  Jian Li,et al.  Accurate Doppler Radar Noncontact Vital Sign Detection Using the RELAX Algorithm , 2010, IEEE Transactions on Instrumentation and Measurement.

[14]  Changzhi Li,et al.  A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring , 2013, IEEE Transactions on Microwave Theory and Techniques.

[15]  Yang Yang,et al.  Application of Parameterized Time-Frequency Analysis on Multicomponent Frequency Modulated Signals , 2014, IEEE Transactions on Instrumentation and Measurement.

[16]  A. C. Raptis,et al.  Compact Millimeter-Wave Sensor for Remote Monitoring of Vital Signs , 2012, IEEE Transactions on Instrumentation and Measurement.

[17]  Dennis R. Morgan,et al.  Vital-Sign Extraction Using Bootstrap-Based Generalized Warblet Transform in Heart and Respiration Monitoring Radar System , 2016, IEEE Transactions on Instrumentation and Measurement.

[18]  J. Lin,et al.  Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human Body , 2006, IEEE Transactions on Microwave Theory and Techniques.

[19]  Norman J. Beamish,et al.  ON THE DIRECT CONVERSION RECEIVER -- A TUTORIAL , 2001 .

[20]  M. Budge,et al.  Range correlation effects on phase and amplitude noise , 1993, Proceedings of Southeastcon '93.

[21]  Changzhi Li,et al.  Robust Overnight Monitoring of Human Vital Signs by a Non-contact Respiration and Heartbeat Detector , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  Majid Sarrafzadeh,et al.  Robust Doppler radar demodulation via compressed sensing , 2012 .

[23]  Changzhi Li,et al.  Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection , 2008, IMS 2008.

[24]  Olga Boric-Lubecke,et al.  Quadrature Imbalance Compensation With Ellipse-Fitting Methods for Microwave Radar Physiological Sensing , 2014, IEEE Transactions on Microwave Theory and Techniques.